Enzyme Biosensor Based on Plasma-Polymerized Film-Covered Carbon Nanotube Layer Grown Directly on A Flat Substrate

被引:27
|
作者
Muguruma, Hitoshi [1 ]
Hoshino, Tatsuya [1 ]
Matsui, Yasunori [1 ]
机构
[1] Shibaura Inst Technol, Dept Elect Engn, Koto Ku, Tokyo 1358548, Japan
关键词
plasma-polymerized film; amperometric biosensor; glucose oxidase; carbon nanotube; direct grown on substrate; acetonitrile monomer; AMPEROMETRIC GLUCOSE BIOSENSOR; THIN-FILM; GOLD ELECTRODE; OXIDASE; SENSOR; MASS; ADSORPTION; COMPOSITE; PLATFORM;
D O I
10.1021/am200342q
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We report a novel approach to fabrication of an amperometric biosensor with an enzyme, a plasma-polymerized film (PPF), and carbon nanotubes (CNTs). The CNTs were grown directly on an island-patterned Co/Ti/Cr layer on a glass substrate by microwave plasma enhanced chemical vapor deposition. The as-grown CNTs were subsequently treated by nitrogen plasma, which changed the surface from hydrophobic to hydrophilic in order to obtain an electrochemical contact between the CNTs and enzymes. A glucose oxidase (GOx) enzyme was then adsorbed onto the CNT surface and directly treated with acetonitrile plasma to overcoat the GOx layer with a PPE This fabrication process provides a robust design of CNT-based enzyme biosensor, because of all processes are dry except the procedure for enzyme immobilization. The main novelty of the present methodology lies in the PPF and/or plasma processes. The optimized glucose biosensor revealed a high sensitivity of 38 mu A mM(-1) cm(-2), a broad linear dynamic range of 0.25-19 mM (correlation coefficient of 0.994), selectivity toward an interferent (ascorbic acid), and a fast response time of 7s. The background current was much smaller in magnitude than the current due to 10 mM glucose response. The low limit of detection was 34 mu M (S/N = 3). All results strongly suggest that a plasma-polymerized process can provide a new platform for CNT-based biosensor design.
引用
收藏
页码:2445 / 2450
页数:6
相关论文
共 20 条
  • [1] Optimization of Carbon Nanotube Layer Formation on Plasma-Polymerized Thin Film for Enzyme Biosensor
    Matsui, Yasunori
    Yoshizawa, Masahiro
    Hoshino, Tatsuya
    Muguruma, Hitoshi
    SENSORS AND MATERIALS, 2008, 20 (06) : 289 - 298
  • [2] Amperometric Biosensor Based on Carbon Nanotube Functionalized by Redox Plasma-Polymerized Film
    Hoshino, Tatsuya
    Muguruma, Hitoshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2011, 50 (08)
  • [3] Amperometric Biosensor with Composites of Carbon Nanotube, Hexaamineruthenium(III)chloride, and Plasma-Polymerized Film
    Hoshino, Tatsuya
    Inoue, Takahiro
    Muguruma, Hitoshi
    IEICE TRANSACTIONS ON ELECTRONICS, 2013, E96C (12): : 1536 - 1540
  • [4] A potentiometric acetylcholinesterase biosensor based on plasma-polymerized film
    Liu, B
    Yang, YH
    Wu, ZY
    Wang, H
    Shen, GL
    Yu, RQ
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 104 (02): : 186 - 190
  • [5] An amperometric biosensor based on a composite of single-walled carbon nanotubes, plasma-polymerized thin film, and an enzyme
    Muguruma, Hitoshi
    Shibayama, Yu
    Matsui, Yasunori
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (06): : 827 - 832
  • [6] Amperometric biosensor based on multilayer containing carbon nanotube, plasma-polymerized film, electron transfer mediator phenothiazine, and glucose dehydrogenase
    Hoshino, Tatsuya
    Sekiguchi, Shin-ichiro
    Muguruma, Hitoshi
    BIOELECTROCHEMISTRY, 2012, 84 : 1 - 5
  • [7] NADH sensing using a carbon nanotube electrode reinforced with a plasma-polymerized thin film
    Matsui, Yasunori
    Hoshlno, Tatsuya
    Yoshizawa, Masahiro
    Muguruma, Hitoshi
    ELECTROCHEMISTRY, 2008, 76 (08) : 610 - 613
  • [8] Thin-film glucose biosensor based on plasma-polymerized film: Simple design for mass production
    Muguruma, H
    Hiratsuka, A
    Karube, I
    ANALYTICAL CHEMISTRY, 2000, 72 (11) : 2671 - 2675
  • [9] Oxygen biosensor based on carbon nanotubes directly grown on graphitic substrate
    Zelechowska, K.
    Trawinski, B.
    Draminska, S.
    Majdecka, D.
    Bilewicz, R.
    Kusz, B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 240 : 1308 - 1313
  • [10] NADH Sensing Using Neutral Red Functionalized Carbon Nanotube/Plasma-Polymerized Film Composite Electrode
    Hoshino, Tatsuya
    Muguruma, Hitoshi
    IEICE TRANSACTIONS ON ELECTRONICS, 2012, E95C (07) : 1300 - 1303