A new wavelength-resolved thermo luminescence (TL) cum optically stimulated luminescence (OSL) reader system has been designed and developed. This reader system uses the compact Seya-Namioka optical layout based monochromator, PMT, and resistive heating method to acquire TL glow curve emissions spectrum. The phosphor samples heated from room temperature to 400 degrees C, either linearly with a programmable heating rate of 0.01 to 30 K s(-1) or alternative constant step temperature profiles. The TL glow curve emission spectrum has been resolved by rotating the grating attached to a monochromator covering the wavelength from 200 to 900 nm. The wavelength scanning is linear with respect to time and the scan rate can be selected from 0.1 to 8 n m s(-1). A broad spectral response of the PMT detection module has been used to record the emitted TL spectrum. The blue (465 nm) reference LED light source is provided for a spectrum calibration of the monochromator. The isometric 3D TL emission spectra of LiCaAlF6:Eu,Y, alpha-Al2O3:C, and CaSO4:Dy have been successfully recorded using this reader system. In order to record the OSL emission spectrum, 470 nm blue LEDs have been provided as a separate stimulation module.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Wavelength-resolved 3-dimensional fluorescence lifetime imaging
    Webb, SED
    Lévêque-Fort, S
    Elson, DS
    Siegel, J
    Watson, T
    Lever, MJ
    Booth, M
    Juskaitis, R
    Neil, MAA
    Sucharov, LO
    Wilson, T
    French, PMW
    JOURNAL OF FLUORESCENCE, 2002, 12 (02) : 279 - 283
  • [2] Wavelength-Resolved 3-Dimensional Fluorescence Lifetime Imaging
    S. E. D. Webb
    S. Lévêque-Fort
    D. S. Elson
    J. Siegel
    T. Watson
    M. J. Lever
    M. Booth
    R. Juskaitis
    M. A. A. Neil
    L. O. Sucharov
    T. Wilson
    P. M. W. French
    Journal of Fluorescence, 2002, 12 : 279 - 283
  • [3] Development of pulsed stimulation and Photon Timer attachments to the Riso TL/OSL reader
    Lapp, T.
    Jain, M.
    Ankjaergaard, C.
    Pirtzel, L.
    RADIATION MEASUREMENTS, 2009, 44 (5-6) : 571 - 575
  • [4] Development of cryostat integrated TL/OSL reader for its application in radiation dosimetry
    Soni, A.
    Mishra, D. R.
    Gaur, S. S.
    Uke, M.
    Sawant, P.
    Koul, D. K.
    Datta, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 935 : 191 - 197
  • [5] Wavelength-resolved study of the photodoping effect in YBa2Cu3Ox
    Markowitsch, W
    Stockinger, C
    Lang, W
    Kula, W
    Sobolewski, R
    APPLIED SUPERCONDUCTIVITY 1997, VOLS 1 AND 2: VOL 1: SMALL SCALE AND ELECTRONIC APPLICATIONS; VOL 2: LARGE SCALE AND POWER APPLICATIONS, 1997, (158): : 117 - 120
  • [6] Design of a Single-Fiber, Wavelength-Resolved System for Monitoring Deep Tissue Oxygenation
    Yu, Linhui
    Murari, Kartikeya
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3707 - 3710
  • [7] Development of a prototype TL/OSL reader for on-site use in a large-scale radiological accident
    Kim, Hyoungtaek
    Park, Chang -Young
    Kim, Sang In
    Kim, Min Chae
    Lee, Jungil
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2024, 56 (06) : 2113 - 2119
  • [8] Bragg-edge attenuation spectra at voxel level from 4D wavelength-resolved neutron tomography
    Carminati, Chiara
    Strobl, Markus
    Minniti, Triestino
    Boillat, Pierre
    Hovind, Jan
    Morgano, Manuel
    Rod, Thomas Holm
    Polatidis, Efthymios
    Valsecchi, Jacopo
    Mannes, David
    Kockelmann, Winfried
    Kaestner, Anders
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2020, 53 : 188 - 196
  • [9] PHOTOFRAGMENTATION DYNAMICS OF ACETONE OF 193 NM - STATE DISTRIBUTIONS OF THE CH3 AND CO FRAGMENTS BY TIME-RESOLVED AND WAVELENGTH-RESOLVED INFRARED-EMISSION
    DONALDSON, DJ
    LEONE, SR
    JOURNAL OF CHEMICAL PHYSICS, 1986, 85 (02): : 817 - 824
  • [10] Excitation energy transfer from phycobiliprotein to chlorophyll d in intact cells of Acaryochloris marina studied by time- and wavelength-resolved fluorescence spectroscopy
    Petrásek, Z
    Schmitt, FJ
    Theiss, C
    Huyer, J
    Chen, M
    Larkum, A
    Eichler, HJ
    Kemnitz, K
    Eckert, HJ
    PHOTOCHEMICAL & PHOTOBIOLOGICAL SCIENCES, 2005, 4 (12) : 1016 - 1022