The Xylum Clot Signature Analyzer®:: A dynamic flow system that simulates vascular injury

被引:32
作者
Li, CKN [1 ]
Hoffmann, TJ [1 ]
Hsieh, PY [1 ]
Malik, S [1 ]
Watson, WC [1 ]
机构
[1] Xylum Corp, Scarsdale, NY 10583 USA
关键词
hemostasis; platelets; coagulation; analyzer; flow; aggregation; shear; collagen;
D O I
10.1016/S0049-3848(98)00163-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The Xylum Clot Signature Analyzer(R) (CSA) is an automated, user-friendly, benchtop analyzer that assesses platelet function and coagulation in nonanticoagulated whole blood under physiological flow and temperature conditions. From blood drawn in a single venipuncture, the CSA measures: a) the time for platelets to occlude holes "punched" in a blood conduit (platelet hemostasis time or PI-IT); b) collagen-induced thrombus formation (CITF) as blood flows in a channel containing a collagen fiber; and c) clotting time (CT). Micrographs show platelet-rich thrombi in the punched holes and on the collagen surface after a run. PI-IT and CITF increased at lower shear rate, suggesting that shear activation of platelets is involved in hole closure and in collagen-induced thrombus formation. In blood mixed with anti-von Willebrand's factor (vWF) antibodies, anti-GPIb antibodies, aurin tricarboxylic acid (ATA), or anti-GPIIb-IIIa, PHT and CITF were prolonged, further supporting the reflection of platelet function by those parameters. At low shear rate (<1000 sec(-1)), native blood and blood treated with anti-vWF did not have significantly different PHTs or CITFs. At high shear rate (>6000 sec(-1)), the PHT and CITF of the anti-vWF-treated sample were significantly greater than those of the untreated sample. This supports the inhibition of shear-induced activation of platelets by anti-vWF in the CSA. Heparin-treated blood showed significantly longer CT, indicating that coagulation of blood under flow is inhibited by heparin. The CSA thus assess multiple aspects of hemostasis under near-physiological conditions. (C) 1998 Elsevier Science Ltd.
引用
收藏
页码:S67 / S77
页数:11
相关论文
共 11 条
[1]   MOLECULAR DEFECTS IN INTERACTIONS OF PLATELETS WITH THE VESSEL WALL [J].
GEORGE, JN ;
NURDEN, AT ;
PHILLIPS, DR .
NEW ENGLAND JOURNAL OF MEDICINE, 1984, 311 (17) :1084-1098
[2]   HEMOSTATOMETER - A NEW INVITRO TECHNIQUE FOR ASSESSING HEMOSTATIC ACTIVITY OF BLOOD [J].
GOROG, P ;
AHMED, A .
THROMBOSIS RESEARCH, 1984, 34 (04) :341-357
[3]  
Kroll MH, 1996, BLOOD, V88, P1525
[4]  
Li CKN, 1997, CLIN CHEM, V43, P1788
[5]   A FLOW DYNAMIC TECHNIQUE USED TO ASSESS GLOBAL HEMOSTASIS [J].
MUGA, KM ;
MELTON, LG ;
GABRIEL, DA .
BLOOD COAGULATION & FIBRINOLYSIS, 1995, 6 (01) :73-78
[6]  
PANTON RL, 1984, INCOMPRESSIBLE FLOW, P161
[7]  
PLOW EF, 1986, BIOCH PLATELETS, P226
[8]  
RUGGERI ZM, 1994, SEMIN HEMATOL, V31, P229
[9]  
SIXMA JJ, 1995, SEMIN HEMATOL, V32, P89
[10]   AURINTRICARBOXYLIC ACID IN A CANINE MODEL OF CORONARY-ARTERY THROMBOSIS [J].
STRONY, J ;
PHILLIPS, M ;
BRANDS, D ;
MOAKE, J ;
ADELMAN, B .
CIRCULATION, 1990, 81 (03) :1106-1114