Improvement of hydrogen embrittlement and stress corrosion cracking by annealing for Al-4.4Mg-0.6Mn alloy

被引:7
作者
Kim, Seong-Jong [1 ]
Han, Min-Su [1 ]
Kim, Seong-Kweon [2 ]
Jang, Seok-Ki [1 ]
机构
[1] Mokpo Natl Maritime Univ, Div Marine Engn, Mokpo 530729, Jeonnam, South Korea
[2] Seoul Natl Univ Technol, Seoul 139743, South Korea
来源
TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA | 2011年 / 21卷
关键词
annealing; 5083F Al-Mg alloy; corrosion; seawater; slow strain rate tests; ARTIFICIAL SEA-WATER; CALCAREOUS DEPOSITS; PROTECTION; CACO3;
D O I
10.1016/S1003-6326(11)61053-4
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
With no annealing treatment, cathodic polarization trends in 5083F Al alloy revealed concentration polarization and activation polarization. However, the annealed specimens have lower current densities at corrosion protection potential compared to the non-annealed specimen. The results of SSRTs conducted in seawater at the applied potential range of -1.8 V to -0.5 V indicated that the maximum tensile strength, elongation, and time-to-fracture had high values at applied potentials of -0.7 to -1.4 V. The maximum tensile strength, elongation, and time-to-fracture decreased when the potential values were beyond this range in either anodic or cathodic direction. In general, the increased shear lip caused by annealing treatment indicates elongation. Time-to-fracture would likely increase with elongation. Potentials between -0.5 V to -0.6 V were found to be in the region of stress corrosion cracking. The corrosion protection zone was determined to be -0.7 V to -1.4 V because these potential ranges produced good mechanical properties. Potential less than -1.4 V produced a fractured surface with a mixture of dimples (ductile fractures) and a quasi-cleavage pattern resulting from the effects of hydrogen gas.
引用
收藏
页码:S17 / S22
页数:6
相关论文
共 14 条
[1]   Characterization of calcareous deposits in artificial sea water by impedances techniques:: 2-deposit of Mg(OH)2 without CaCO3 [J].
Deslouis, C ;
Festy, D ;
Gil, O ;
Maillot, V ;
Touzain, S ;
Tribollet, B .
ELECTROCHIMICA ACTA, 2000, 45 (11) :1837-1845
[2]   Characterization of calcareous deposits in artificial sea water by impedance techniques -: I.: Deposit of CaCO3 without Mg(OH)2 [J].
Deslouis, C ;
Festy, D ;
Gil, O ;
Rius, G ;
Touzain, S ;
Tribollet, B .
ELECTROCHIMICA ACTA, 1998, 43 (12-13) :1891-1901
[3]  
HUANG GQ, 2002, CORROSION SCI TECHNO, V31, P215
[4]  
Kim Hwan Tae, 2007, CORROSION SCIENCE AND TECHNOLOGY, V6, P33
[5]   Evaluation of the characteristics using slow strain rate tests of 5456 Al-Mg alloy for ship construction [J].
Kim, Seong-Jong ;
Ko, Jae-Yong ;
Han, Min Su .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2006, 23 (06) :1028-1033
[6]   Evaluating the electrochemical properties in the protection potential of material for use in Al vessels in seawater [J].
Kim, Seong-Jong .
ECO-MATERIALS PROCESSING & DESIGN VII, 2006, 510-511 :158-161
[7]   Hydrogen embrittlement properties of heat affected zone of high strength steel in shielded metal arc welding [J].
Kim, SJ ;
Moon, KM .
METALS AND MATERIALS INTERNATIONAL, 2002, 8 (04) :395-401
[8]   The relationship between corrosion protection and hydrogen embrittlement properties of HAZ in flux cored arc welding [J].
Kim, SJ ;
Moon, KM .
METALS AND MATERIALS INTERNATIONAL, 2002, 8 (04) :387-393
[9]  
KIM SJ, 2005, 56 ANN M INT SOC ELE, V751
[10]   Calcareous scales formed by cathodic protection - an assessment of characteristics and kinetics [J].
Neville, A ;
Morizot, AP .
JOURNAL OF CRYSTAL GROWTH, 2002, 243 (3-4) :490-502