Assessment of rigid multi-modality image registration consistency using the multiple sub-volume registration (MSR) method

被引:11
作者
Ceylan, C [1 ]
van der Heide, UA [1 ]
Bol, GH [1 ]
Lagendijk, JJW [1 ]
Kotte, ANTJ [1 ]
机构
[1] Univ Utrecht, Med Ctr, Dept Radiotherapy, Utrecht, Netherlands
关键词
D O I
10.1088/0031-9155/50/10/N01
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Registration of different imaging modalities such as CT, MRI, functional MRI (fMRI), positron (PET) and single photon (SPECT) emission tomography is used in many clinical applications. Determining the quality of any automatic registration procedure has been a challenging part because no gold standard is available to evaluate the registration. In this note we present a method, called the 'multiple sub-volume registration' (MSR) method, for assessing the consistency of a rigid registration. This is done by registering sub-images of one data set on the other data set, performing a crude non-rigid registration. By analysing the deviations (local deformations) of the sub-volume registrations from the full registration we get a measure of the consistency of the rigid registration. Registration of 15 data sets which include CT, MR and PET images for brain, head and neck, cervix, prostate and lung was performed utilizing a rigid body registration with nonnalized mutual information as the similarity measure. The resulting registrations were classified as good or bad by visual inspection. The resulting registrations were also classified using our MSR method. The results of our MSR method agree with the classification obtained from visual inspection for all cases (p < 0.02 based on ANOVA of the good and bad groups). The proposed method is independent of the registration algorithm and similarity measure. It can be used for multi-modality image data sets and different anatomic sites of the patient.
引用
收藏
页码:N101 / N108
页数:8
相关论文
共 18 条
[1]   The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer [J].
Debois, M ;
Oyen, R ;
Maes, F ;
Verswijvel, G ;
Gatti, G ;
Bosmans, H ;
Feron, M ;
Bellon, E ;
Kutcher, G ;
Van Poppel, H ;
Vanuytsel, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04) :857-865
[2]   Automatic MR volume registration and its evaluation for the pelvis and prostate [J].
Fei, BW ;
Wheaton, A ;
Lee, ZH ;
Duerk, JL ;
Wilson, DL .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05) :823-838
[3]  
FITZPATRICK JM, 2001, MED IMAGE REGISTRATI, pCH5
[4]   Medical image registration [J].
Hill, DLG ;
Batchelor, PG ;
Holden, M ;
Hawkes, DJ .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (03) :R1-R45
[5]   Voxel similarity measures for 3-D serial MR brain image registration [J].
Holden, M ;
Hill, DLG ;
Denton, ERE ;
Jarosz, JM ;
Cox, TCS ;
Rohlfing, T ;
Goodey, J ;
Hawkes, DJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (02) :94-102
[6]   Magnetic resonance imaging (MRI): Considerations and applications in radiotherapy treatment planning [J].
Khoo, VS ;
Dearnaley, DP ;
Finnigan, DJ ;
Padhani, A ;
Tanner, SF ;
Leach, MO .
RADIOTHERAPY AND ONCOLOGY, 1997, 42 (01) :1-15
[7]   Matching PET and CT scans of the head and neck area: Development of method and validation [J].
Klabbers, BM ;
de Munck, JC ;
Slotman, BJ ;
Langendijk, HA ;
de Bree, R ;
Hoekstra, OS ;
Boellaard, R ;
Lammertsma, AA .
MEDICAL PHYSICS, 2002, 29 (10) :2230-2238
[8]   Multimodality image registration by maximization of mutual information [J].
Maes, F ;
Collignon, A ;
Vandermeulen, D ;
Marchal, G ;
Suetens, P .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) :187-198
[9]   Multimodality image registration quality assurance for conformal three-dimensional treatment planning [J].
Mutic, S ;
Dempsey, JF ;
Bosch, WR ;
Low, DA ;
Drzymala, RE ;
Chao, KSC ;
Goddu, SM ;
Cutler, PD ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (01) :255-260
[10]  
Panigrahy A, 2000, AM J NEURORADIOL, V21, P282