Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

被引:3
作者
Strydhorst, Jared H. [1 ]
Ruddy, Terrence D. [1 ]
Wells, R. Glenn [1 ]
机构
[1] Univ Ottawa, Inst Heart, Cardiac Imaging, Ottawa, ON K1Y 4W7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
small animal SPECT; myocardial perfusion; repeatability; attenuation correction; quantification; IMPROVED QUANTIFICATION; PINHOLE SPECT; SMALL ANIMALS; COLLIMATION; INFORMATION; INFARCTION; SYSTEM;
D O I
10.1118/1.4915083
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with Tc-99m and Tl-201 single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with Tc-99m-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with Tl-201 and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of Tc-99m in the heart was also quantified with and without attenuation correction. Results: For Tc-99m imaging, relative segmental perfusion changed by up to +2.1%/-1.8% as a result of attenuation correction. Relative changes of +3.6%/-1.0% were observed for the Tl-201 images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected Tc-99m scans, and 3.6% and 4.3%, respectively, for the Tl-201 scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1818 / 1824
页数:7
相关论文
共 36 条
[31]   Quantitative CBF measurement using an integrated SPECT/CT system: validation of three-dimensional ordered-subset expectation maximization and CT-based attenuation correction by comparing with O-15 water PET [J].
Shimosegawa, Eku ;
Fujino, Kouichi ;
Kato, Hiroki ;
Hatazawa, Jun .
ANNALS OF NUCLEAR MEDICINE, 2013, 27 (09) :822-833
[32]   Quantitative CBF measurement using an integrated SPECT/CT system: validation of three-dimensional ordered-subset expectation maximization and CT-based attenuation correction by comparing with O-15 water PET [J].
Eku Shimosegawa ;
Kouichi Fujino ;
Hiroki Kato ;
Jun Hatazawa .
Annals of Nuclear Medicine, 2013, 27 :822-833
[33]   Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores [J].
Wells, R. Glenn ;
Soueidan, Karen ;
Timmins, Rachel ;
Ruddy, Terrence D. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2013, 20 (05) :785-796
[34]   Comparison of attenuation, dual-energy-window, and model-based scatter correction of low-count SPECT to 82Rb PET/CT quantified myocardial perfusion scores [J].
R. Glenn Wells ;
Karen Soueidan ;
Rachel Timmins ;
Terrence D. Ruddy .
Journal of Nuclear Cardiology, 2013, 20 :785-796
[35]   Comparison of positional artifacts in myocardial perfusion imaging in supine and semi-reclining position using dedicated D-SPECT cardiac camera: validation using CT based attenuation correction [J].
Sejal Chopra ;
Shashank Shekhar Singh ;
Ashwani Sood ;
Madan Parmar ;
Ashwin Singh Parihar ;
Shelvin Kumar Vadi ;
Bhagwant Rai Mittal .
Journal of Nuclear Cardiology, 2023, 30 :1782-1793
[36]   Assessment of Myocardial Viability in Patients with Left Ventricular Dysfunction:Correlation between CT-Based Attenuation Correction and Uncorrected Quantification Analysis in Thallium201(Tl-201)Rest-Redistribution SPECT Study [J].
Malek, Hadi ;
Yaghoobi, Nahid ;
Rastgou, Fereydoon ;
Bitarafan-Rajabi, Ahmad ;
Alvandi, Maryam ;
Kargar, Mahsa ;
Hedayati, Raheleh ;
Amouzadeh, Hedieh ;
Hosseini, Shirin ;
Firoozabadi, Hassan .
IRANIAN HEART JOURNAL, 2013, 13 (04) :15-20