Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

被引:3
作者
Strydhorst, Jared H. [1 ]
Ruddy, Terrence D. [1 ]
Wells, R. Glenn [1 ]
机构
[1] Univ Ottawa, Inst Heart, Cardiac Imaging, Ottawa, ON K1Y 4W7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
small animal SPECT; myocardial perfusion; repeatability; attenuation correction; quantification; IMPROVED QUANTIFICATION; PINHOLE SPECT; SMALL ANIMALS; COLLIMATION; INFORMATION; INFARCTION; SYSTEM;
D O I
10.1118/1.4915083
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with Tc-99m and Tl-201 single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with Tc-99m-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with Tl-201 and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of Tc-99m in the heart was also quantified with and without attenuation correction. Results: For Tc-99m imaging, relative segmental perfusion changed by up to +2.1%/-1.8% as a result of attenuation correction. Relative changes of +3.6%/-1.0% were observed for the Tl-201 images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected Tc-99m scans, and 3.6% and 4.3%, respectively, for the Tl-201 scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1818 / 1824
页数:7
相关论文
共 36 条
  • [21] Clinical Impact of Nonuniform CT-Based Attenuation Correction in Brain Perfusion SPECT/CT Using 99mTc-ECD
    Farid, Karim
    Petras, Slavomir
    Poullias, Xavier
    Caillat-Vigneron, Nadine
    CLINICAL NUCLEAR MEDICINE, 2014, 39 (06) : E343 - E345
  • [22] CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification
    Christos A. Savvopoulos
    Trifon Spyridonidis
    Nikolaos Papandrianos
    Pavlos J. Vassilakos
    Dimitrios Alexopoulos
    Dimitris J. Apostolopoulos
    Journal of Nuclear Cardiology, 2014, 21 : 519 - 531
  • [23] CT-based attenuation correction in Tl-201 myocardial perfusion scintigraphy is less effective than non-corrected SPECT for risk stratification
    Savvopoulos, Christos A.
    Spyridonidis, Trifon
    Papandrianos, Nikolaos
    Vassilakos, Pavlos J.
    Alexopoulos, Dimitrios
    Apostolopoulos, Dimitris J.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (03) : 519 - 531
  • [24] Attenuation correction of SPECT images based on separately performed CT -: Effect on the measurement of regional uptake values
    Römer, W
    Fiedler, E
    Pavel, M
    Pfahlberg, A
    Hothorn, T
    Herzog, H
    Bautz, W
    Kuwert, T
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 (01): : 20 - 28
  • [25] Quantitative myocardial perfusion SPECT/CT for the assessment of myocardial tracer uptake in patients with three-vessel coronary artery disease: Initial experiences and results
    Lehner, Sebastian
    Nowak, Isabel
    Zacherl, Mathias
    Brosch-Lenz, Julia
    Fischer, Maximilian
    Ilhan, Harun
    Ruebenthaler, Johannes
    Gosewisch, Astrid
    Bartenstein, Peter
    Todica, Andrei
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (05) : 2511 - 2520
  • [26] Quantitative myocardial perfusion SPECT/CT for the assessment of myocardial tracer uptake in patients with three-vessel coronary artery disease: Initial experiences and results
    Sebastian Lehner
    Isabel Nowak
    Mathias Zacherl
    Julia Brosch-Lenz
    Maximilian Fischer
    Harun Ilhan
    Johannes Rübenthaler
    Astrid Gosewisch
    Peter Bartenstein
    Andrei Todica
    Journal of Nuclear Cardiology, 2022, 29 : 2511 - 2520
  • [27] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Nina Burkhard
    Bernhard A. Herzog
    Lars Husmann
    Aju P. Pazhenkottil
    Irene A. Burger
    Ronny R. Buechel
    Ines Valenta
    Christophe A. Wyss
    Philipp A. Kaufmann
    European Journal of Nuclear Medicine and Molecular Imaging, 2010, 37 : 517 - 521
  • [28] Initial experience with X-ray CT based attenuation correction in myocardial perfusion SPECT imaging using a combined SPECT/CT system
    Utsunomiya, D
    Tomiguchi, S
    Shiraishi, S
    Yamada, K
    Honda, T
    Kawanaka, K
    Kojima, A
    Awai, K
    Yamashita, Y
    ANNALS OF NUCLEAR MEDICINE, 2005, 19 (06) : 485 - 489
  • [29] Comparison of quantitative myocardial perfusion imaging CT to fluorescent microsphere-based flow from high-resolution cryo-images
    Eck, Brendan L.
    Fahmi, Rachid
    Levi, Jacob
    Fares, Anas
    Wu, Hao
    Li, Yuemeng
    Vembar, Mani
    Dhanantwari, Amar
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL IMAGING 2016-BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2016, 9788
  • [30] Comparison of positional artifacts in myocardial perfusion imaging in supine and semi-reclining position using dedicated D-SPECT cardiac camera: validation using CT based attenuation correction
    Chopra, Sejal
    Singh, Shashank Shekhar
    Sood, Ashwani
    Parmar, Madan
    Parihar, Ashwin Singh
    Vadi, Shelvin Kumar
    Mittal, Bhagwant Rai
    JOURNAL OF NUCLEAR CARDIOLOGY, 2023, 30 (05) : 1782 - 1793