Effects of CT-based attenuation correction of rat microSPECT images on relative myocardial perfusion and quantitative tracer uptake

被引:3
作者
Strydhorst, Jared H. [1 ]
Ruddy, Terrence D. [1 ]
Wells, R. Glenn [1 ]
机构
[1] Univ Ottawa, Inst Heart, Cardiac Imaging, Ottawa, ON K1Y 4W7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
small animal SPECT; myocardial perfusion; repeatability; attenuation correction; quantification; IMPROVED QUANTIFICATION; PINHOLE SPECT; SMALL ANIMALS; COLLIMATION; INFORMATION; INFARCTION; SYSTEM;
D O I
10.1118/1.4915083
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Our goal in this work was to investigate the impact of CT-based attenuation correction on measurements of rat myocardial perfusion with Tc-99m and Tl-201 single photon emission computed tomography (SPECT). Methods: Eight male Sprague-Dawley rats were injected with Tc-99m-tetrofosmin and scanned in a small animal pinhole SPECT/CT scanner. Scans were repeated weekly over a period of 5 weeks. Eight additional rats were injected with Tl-201 and also scanned following a similar protocol. The images were reconstructed with and without attenuation correction, and the relative perfusion was analyzed with the commercial cardiac analysis software. The absolute uptake of Tc-99m in the heart was also quantified with and without attenuation correction. Results: For Tc-99m imaging, relative segmental perfusion changed by up to +2.1%/-1.8% as a result of attenuation correction. Relative changes of +3.6%/-1.0% were observed for the Tl-201 images. Interscan and inter-rat reproducibilities of relative segmental perfusion were 2.7% and 3.9%, respectively, for the uncorrected Tc-99m scans, and 3.6% and 4.3%, respectively, for the Tl-201 scans, and were not significantly affected by attenuation correction for either tracer. Attenuation correction also significantly increased the measured absolute uptake of tetrofosmin and significantly altered the relationship between the rat weight and tracer uptake. Conclusions: Our results show that attenuation correction has a small but statistically significant impact on the relative perfusion measurements in some segments of the heart and does not adversely affect reproducibility. Attenuation correction had a small but statistically significant impact on measured absolute tracer uptake. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1818 / 1824
页数:7
相关论文
共 36 条
  • [1] What is the benefit of CT-based attenuation correction in myocardial perfusion SPET?
    Apostolopoulos, Dimitrios J.
    Savvopoulos, Christos
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2016, 19 (02): : 89 - 92
  • [2] Clinical Utility of CT-based Attenuation-correction in Myocardial Perfusion SPECT Imaging
    Hatipoglu, Filiz
    Cetin, Neslihan
    MOLECULAR IMAGING AND RADIONUCLIDE THERAPY, 2023, 32 (02) : 138 - 145
  • [3] Effects of CT-based attenuation correction on quantitative SPECT/CT of jawbone
    Tsuchitani, Tatsuya
    Kitajima, Kazuhiro
    Takahashi, Yoshiyuki
    Yoshida, Rika
    Kiada, Hayato
    Tsurusaki, Masakatsu
    Minami, Tetsuya
    Kotura, Noriko
    HELLENIC JOURNAL OF NUCLEAR MEDICINE, 2023, 26 (02) : 108 - 113
  • [4] CT-based attenuation correction in 82Rb-myocardial perfusion PET–CT: incidence of misalignment and effect on regional tracer distribution
    Riikka Lautamäki
    Tracy L. Y. Brown
    Jennifer Merrill
    Frank M. Bengel
    European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 305 - 310
  • [5] CT-based attenuation correction in 82Rb-myocardial perfusion PET-CT:: incidence of misalignment and effect on regional tracer distribution
    Lautamaeki, Riikka
    Brown, Tracy L. Y.
    Merrill, Jennifer
    Bengel, Frank M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (02) : 305 - 310
  • [6] Comparison of Myocardial Perfusion 82Rb PET Performed with CT- and Transmission CT-Based Attenuation Correction
    Slomka, Piotr J.
    Le Meunier, Ludovic
    Hayes, Sean W.
    Acampa, Wanda
    Oba, Muneo
    Haemer, Gillian G.
    Berman, Daniel S.
    Germano, Guido
    JOURNAL OF NUCLEAR MEDICINE, 2008, 49 (12) : 1992 - 1998
  • [7] CT-based attenuation and scatter correction compared with uniform attenuation correction in brain perfusion SPECT imaging for dementia
    Gillen, Rebecca
    Firbank, Michael J.
    Lloyd, Jim
    O'Brien, John T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (17) : 6775 - 6787
  • [8] CT-based myocardial ischemia evaluation: quantitative angiography, transluminal attenuation gradient, myocardial perfusion, and CT-derived fractional flow reserve
    Koo, Hyun Jung
    Yang, Dong Hyun
    Kim, Young-Hak
    Kang, Joon-Won
    Kang, Soo-Jin
    Kweon, Jihoon
    Kim, Hyun Jung
    Lim, Tae-Hwan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 : S1 - S19
  • [9] CT-based myocardial ischemia evaluation: quantitative angiography, transluminal attenuation gradient, myocardial perfusion, and CT-derived fractional flow reserve
    Hyun Jung Koo
    Dong Hyun Yang
    Young-Hak Kim
    Joon-Won Kang
    Soo-Jin Kang
    Jihoon Kweon
    Hyun Jung Kim
    Tae-Hwan Lim
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1 - 19
  • [10] The influence of misregistration between CT and SPECT images on the accuracy of CT-based attenuation correction of cardiac SPECT/CT imaging: Phantom and clinical studies
    Saleki, Leila
    Ghafarian, Pardis
    Bitarafan-Rajabi, Ahmad
    Yaghoobi, Nahid
    Fallahi, Babak
    Ay, Mohammad Reza
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2019, 27 (02): : 63 - 72