Flow cytometric reticulocyte counting - Parallel evaluation of five fully automated analyzers: An NCCLS-ICSH approach

被引:35
作者
Buttarello, M [1 ]
Bulian, P [1 ]
Farina, G [1 ]
Temporin, V [1 ]
Toffolo, L [1 ]
Trabuio, E [1 ]
Rizzotti, P [1 ]
机构
[1] Osped Geriatr, Lab Patol Clin, I-35100 Padua, Italy
关键词
reticulocyte counting; automated analyzers;
D O I
10.1309/M26B-1YNQ-VNU8-M1CE
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
We performed a parallel evaluation of 5 automated reticulocyte analyzers. The guidelines were those proposed by the National Committee for Clinical Laboratory Standards and the International Council for Standardisation in Haematology. Duplicate analyses were performed for 225 healthy subjects and 115 patients affected by various diseases. The reference intervals were different for each method (ADVIA 120, 27-125 x 10(3)/muL [27-125 x 10(9)/L]; CELL DYN 4000, 25-108 x 10(3)/muL [25-108 x 10(9)/L]; GEN-S, 20-85 x 10(3)/muL, [20-85 x 10(9)/L]; SE 9500 RET: 23-95 x 10(3)/muL [23-95 x 10(9)/L]; and VEGA RETIC, 30-130 x 10(3)/muL [30-130 x 10(9)/L]). The comparisons of percentage counts with the microscopic reference method were satisfactory for all automated methods. However a tendency to overestimate at low counts was noted. This progressively increased from the SE 9500 RET to the VEGA RETIC. The imprecision was excellent for all the methods at normal and high concentrations. This was higher at low concentrations. When compared with the microscopic reference, the analyzers showed satisfactory sensitivity at low counts and excellent sensitivity at high counts. The overall agreement varied from 74.8% for the GEN-S to 86.1% for the SE 9500 RET.
引用
收藏
页码:100 / 111
页数:12
相关论文
共 25 条
[1]  
[Anonymous], 1997, LAB HEMATOL
[2]   Reticulocyte hemoglobin content to diagnose iron deficiency in children [J].
Brugnara, C ;
Zurakowski, D ;
DiCanzio, J ;
Boyd, T ;
Platt, O .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1999, 281 (23) :2225-2230
[3]  
Buttarello M, 1997, AM J CLIN PATHOL, V108, P674
[4]  
Buttarello M, 1995, ARCH PATHOL LAB MED, V119, P1141
[5]   Evaluation of the Abbott Cell Dyn 4000 automated fluorescent reticulocyte measurements:: comparison with manual, FACScan and Sysmex R1000 methods [J].
d'Onofrio, G ;
Kim, YR ;
Schulze, S ;
Lorentz, T ;
Dörner, K ;
Goossens, W ;
Zini, G ;
Tommasi, M ;
Kendall, R ;
Scott, CS .
CLINICAL AND LABORATORY HAEMATOLOGY, 1997, 19 (04) :253-260
[6]   FLOW CYTOMETRIC RETICULOCYTE ANALYSIS - MULTIINSTITUTIONAL INTERLABORATORY CORRELATION STUDY [J].
DAVIS, BH ;
BIGELOW, NC ;
KOEPKE, JA ;
BOROWITZ, MJ ;
HOUWEN, B ;
JACOBBERGER, JW ;
PIERRE, RV ;
CORASH, L ;
AULT, KA ;
BATJER, JD .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1994, 102 (04) :468-477
[7]  
DAVIS BH, 1997, LAB HEMATOL, V3, P84
[8]  
Davis BH., 1996, Lab Hematol, V2, P2
[9]  
ENGLAND JM, 1994, CLIN LAB HAEMATOL, V16, P157
[10]   Proposed reference method for reticulocyte counting based on the determination of the reticulocyte to red cell ratio [J].
England, JM ;
Rowan, RM ;
Van Assendelft, OW ;
Bull, BS ;
Coulter, WH ;
Fujimoto, K ;
Groner, W ;
Van Hove, I ;
Jones, AR ;
Kanter, RJ ;
Klee, GG ;
Koepke, JA ;
Lewis, SM ;
D'Onofrio, G ;
Tatsumi, N ;
McLaren, CE .
CLINICAL AND LABORATORY HAEMATOLOGY, 1998, 20 (02) :77-79