Information fusion of plume control and personnel escape during the emergency rescue of external-caused fire in a coal mine

被引:50
作者
Wang, Kai [1 ,2 ,3 ]
Jiang, Shuguang [1 ,3 ,4 ]
Ma, Xiaoping [2 ]
Wu, Zhengyan [1 ,3 ]
Shao, Hao [1 ,3 ]
Zhang, Weiqing [4 ]
Cui, Chuanbo [1 ,3 ]
机构
[1] China Univ Min & Technol, Key Lab Coal Methane & Fire Control, Minist Educ, Xuzhou, Peoples R China
[2] China Univ Min & Technol, Sch Informat & Elect Engn, Xuzhou, Peoples R China
[3] China Univ Min & Technol, Sch Safety Engn, Xuzhou 22116, Peoples R China
[4] China Univ Min & Technol, State Key Lab Coal Resources & Safe Min, Xuzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Fire plume control; Personnel escape; Information fusion; Emergency rescue; Numerical simulation; LARGE-SCALE TUNNEL; NUMERICAL-SIMULATION; SMOKE; SPREAD; ATRIA;
D O I
10.1016/j.psep.2016.06.026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
After a fire occurred in a coal mine, compared with putting out the fire, organizing the miners' safe escape was especially important. We established a local ventilation system model using TEPS (Thunderhead Engineering PyroSim) and set up control measures for fire smoke. The change rule of fire parameters, such as temperature, concentration of smoke, and visibility, was analyzed based on the results of FDS (Fire Dynamics Simulator). Without the control measures for fire smoke, the coal face and the intake airflow roadway were all polluted by smoke at 541 s after the fire broke out; at this time, personnel escape would be almost impossible in the coal face. Thus, the personnel escape conditions and routes are determined by the parameters of fire smoke flow. Evac was used to simulate the escape behavior of a miner who encounters an accident in a coal mine. After taking the fire smoke control measures into account, we perfomied simulation calculation to determine the best and fastest way for miners' escape. We exploited the hardware and software, and the belt fire emergency rescue system of the No. 1 plate in the Da Liu-ta coal mine was established. The emergency rescue system successfully fused fire plume control and personnel escape information into one platform. Through simulating a fire drill three times, the air quantity of the key branches changed to within reasonable limits while the air-door's opening area was 2 m(2), field tests proved the reliability and feasibility of the system. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:46 / 59
页数:14
相关论文
共 38 条
[1]  
Cecelia W.B., 2005, THESIS
[2]  
Edwards J.C., 1999, Proceedings of the 8th US Mine Ventilation Symposium, P417
[3]   MODELING OF THE OPERATION OF A MINE COUNTERROTATION FAN BY MEANS OF THE FLUENT SUITE [J].
Gurina, E. I. .
JOURNAL OF ENGINEERING PHYSICS AND THERMOPHYSICS, 2010, 83 (05) :985-990
[4]  
Hansen R., 2009, LIT SURVEY FIRE SMOK, P2
[5]  
He XJ, 2008, COAL SCI TECHNOL, V36, P53
[6]  
Hostikka S., 2009, FIRE DYNAMICS SIMULA, P28
[7]   Extension of Euler's method to parabolic equations [J].
Ibragimov, N. H. .
COMMUNICATIONS IN NONLINEAR SCIENCE AND NUMERICAL SIMULATION, 2009, 14 (04) :1157-1168
[8]  
[李翠平 Li Cuiping], 2013, [煤炭学报, Journal of China Coal Society], V38, P257
[9]  
[李翠平 Li Cuiping], 2012, [北京科技大学学报, Journal of University Science and Technology Beijing], V34, P744
[10]  
Lin W.J., 2014, COAL ENG, V46, P4