Determination of Imatinib and CGP74588 in Rat Plasma by HPLC and Its Application to a Pharmacokinetic Study

被引:4
作者
Lin, Jiamiao [1 ,2 ]
Ying, Na [3 ]
Wu, Yanli [1 ,2 ]
Lin, Gaotong [3 ]
机构
[1] Shulan Hangzhou Hosp, Dept Pharm, Hangzhou, Zhejiang, Peoples R China
[2] Zhejiang Univ, Int Hosp, Hangzhou, Zhejiang, Peoples R China
[3] Taizhou Canc Hosp, Dept Pharm, Wenling, Zhejiang, Peoples R China
关键词
HPLC; rat; pharmacokinetics; imatinib; CGP74588; N-desmethyl imatinib; PERFORMANCE LIQUID-CHROMATOGRAPHY; TANDEM MASS-SPECTROMETRY; MESYLATE; ASSAY;
D O I
10.2174/1573412913666161121105119
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: A simple, reliable and specific method of HPLC which was performed on a reversed- phase Agilent SB column was developed for the determination of imatinib and CGP74588. Method: The mobile phase comprised water-acetonitrile-0.1% trifluoroacetic acid (59: 21: 20, v/v/v) flowed at the rate of 1 mL/min at 40 degrees C. The detection wavelength was 278nm. Results: Sensitivity has been illustrated in this method, and a good linear relationship was observed between 0.1-20.00 mu g/mL for imatinib with r(2) = 0.9994 and 0.01-2.00 mu g/mL for CGP74588 with r(2) = 0.9998 in rat plasma. The relative recoveries of imatinib and CGP74588 were all more than 93%, whilst the absolute recoveries of imatinib and CGP74588 were all more than 75%. Both intra-and inter-day precisions were all less than 4.5% for imatinib and 4.74% for GCP74588. The limits of quantification of these analytic methods were 0.1 mu g/mL for imatinib and 0.01 mu g/mL for CGP74588. Conclusion: The method was suitable for studying the pharmacokinetic parameters of imatinib and GCP74588 and routine analysis.
引用
收藏
页码:133 / 138
页数:6
相关论文
共 11 条
[1]   Development and validation of a stability indicating RP-LC method for determination of imatinib mesylate [J].
Bende, Girish ;
Kollipara, Sivacharan ;
Kolachina, Venugopal ;
Saham, Ranendra .
CHROMATOGRAPHIA, 2007, 66 (11-12) :859-866
[2]  
Bodeau S, 2015, FUND CLIN PHARMACOL, V29, P34
[3]   Simultaneous determination of nine tyrosine kinase inhibitors by 96-well solid-phase extraction and ultra performance LC/MS-MS [J].
Bouchet, Stephane ;
Chauzit, Emmanuelle ;
Ducint, Dominique ;
Castaing, Nadege ;
Canal-Raffin, Mireille ;
Moore, Nicholas ;
Titier, Karine ;
Molimard, Mathieu .
CLINICA CHIMICA ACTA, 2011, 412 (11-12) :1060-1067
[4]   Role of upfront genomic analysis of gastrointestinal stromal tumors to identify imatinib-insensitive or resistant cases [J].
Chojecki, Aleksander ;
Moss, Rebecca A. ;
Zhong, Hua ;
Poplin, Elizabeth ;
Ronnen, Ellen ;
Ganesan, Shridar ;
Rodriguez, Lorna Rodriguez ;
Hirshfield, Kim M. .
CLINICAL CANCER RESEARCH, 2016, 22
[5]   Phase II, Open-Label, Single-Arm Trial of Imatinib Mesylate in Patients With Metastatic Melanoma Harboring c-Kit Mutation or Amplification [J].
Guo, Jun ;
Si, Lu ;
Kong, Yan ;
Flaherty, Keith T. ;
Xu, Xiaowei ;
Zhu, Yanyan ;
Corless, Christopher L. ;
Li, Li ;
Li, Haifu ;
Sheng, Xinan ;
Cui, Chuanliang ;
Chi, Zhihong ;
Li, Siming ;
Han, Mei ;
Mao, Lili ;
Lin, Xuede ;
Du, Nan ;
Zhang, Xiaoshi ;
Li, Junling ;
Wang, Baocheng ;
Qin, Shukui .
JOURNAL OF CLINICAL ONCOLOGY, 2011, 29 (21) :2904-2909
[6]   Imatinib in advanced chordoma: A retrospective case series analysis [J].
Hindi, Nadia ;
Casali, Paolo G. ;
Morosi, Carlo ;
Messina, Antonella ;
Palassini, Elena ;
Pilotti, Silvana ;
Tamborini, Elena ;
Radaelli, Stefano ;
Gronchi, Alessandro ;
Stacchiotti, Silvia .
EUROPEAN JOURNAL OF CANCER, 2015, 51 (17) :2609-2614
[7]   Six-year follow-up of patients receiving imatinib for the first-line treatment of chronic myeloid leukemia [J].
Hochhaus, A. ;
O'Brien, S. G. ;
Guilhot, F. ;
Druker, B. J. ;
Branford, S. ;
Foroni, L. ;
Goldman, J. M. ;
Mueller, M. C. ;
Radich, J. P. ;
Rudoltz, M. ;
Mone, M. ;
Gathmann, I. ;
Hughes, T. P. ;
Larson, R. A. .
LEUKEMIA, 2009, 23 (06) :1054-1061
[8]   Imatinib assay by high-performance liquid chromatography in tandem mass spectrometry with solid-phase extraction in human plasma [J].
Moreno, Jose Maria ;
Wojnicz, Aneta ;
Steegman, Juan Luis ;
Cano-Abad, Maria F. ;
Ruiz-Nuno, Ana .
BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (04) :502-508
[9]   Determination of imatinib mesylate and its main metabolite (CGP74588) in human plasma and murine specimens by ion-pairing reversed-phase high-performance liquid chromatography [J].
Oostendorp, Roos L. ;
Beijnen, Jos H. ;
Schellens, Jan H. M. ;
van Tellingen, Olaf .
BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (07) :747-754
[10]   Liquid chromatographic-mass spectrometric assay for quantitation of imatinib and its main metabolite (CGP 74588) in plasma [J].
Parise, RA ;
Ramanathan, RK ;
Hayes, MJ ;
Egorin, MJ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2) :39-44