Single Wall Closed-form Differential Ultrasound Calibration

被引:1
|
作者
Najafi, Mohammad [1 ]
Afsham, Narges [1 ]
Abolmaesumi, Purang [1 ]
Rohling, Robert [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
关键词
Free-hand ultrasound; calibration; single wall phantom; closed-form; differential; FREEHAND ULTRASOUND;
D O I
10.1117/12.911459
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In freehand 3D ultrasound, images are acquired while the position of the transducer is recorded with a tracking device. Calibration is essential in this technique to find the transformation from the image coordinates to the reference coordinate system. The single wall technique is a common calibration method because a simple plane phantom is used. Despite its advantages, such as ease of phantom construction and image analysis, this method requires large number of images to converge to the solution. One reason is a lack of a closed-form solution. Also, the technique uses slightly ill-conditioned sets of equations with a high condition number due to limited range of scanning motions that produce clear images of the plane. Here, a novel closed-form formulation has been proposed for the single wall calibration technique. Also, differential measurements of the plane image are used instead of absolute plane detection to improve accuracy. The closed-form solution leads to more accurate and robust results while providing an insight into understanding error propagation and finding the optimal set of transducer poses. Results have been compared to the conventional single wall technique. A residual error of 0.14 mm is achieved for the proposed method compared to 0.91 mm in the conventional approach.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] CLOSED-FORM EQUATIONS TO DESIGN SINGLE SAMPLING PLANS FOR ISOLATED LOTS
    Cavone, Giuseppe
    Fabbiano, Laura
    Giaquinto, Nicola
    XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1137 - 1141
  • [42] Degenerate cases and closed-form solutions for camera calibration with one-dimensional objects
    Hammarstedt, P
    Sturm, P
    Heyden, A
    TENTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS 1 AND 2, PROCEEDINGS, 2005, : 317 - 324
  • [43] Closed-form optimal calibration of a tuned liquid column damper (TLCD) for flexible structures
    Chen, Bei
    Zhang, Zili
    Hua, Xugang
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2021, 198 (198)
  • [44] Closed-Form Solution of Principal Line for Camera Calibration Based on Orthogonal Vanishing Points
    Yang, Fengli
    Zhao, Long
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2023, 33 (02) : 521 - 533
  • [45] Nonmetric lens distortion calibration: Closed-form solutions, robust estimation and model selection
    El-Melegy, MT
    Farag, AA
    NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 554 - 559
  • [46] Closed-Form and Near Closed-Form Solutions for TOA-Based Joint Source and Sensor Localization
    Le, Trung-Kien
    Ono, Nobutaka
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2016, 64 (18) : 4751 - 4766
  • [47] SINGLE-CAMERA CLOSED-FORM REAL-TIME NEEDLE TRACKING FOR ULTRASOUND-GUIDED NEEDLE INSERTION
    Najafi, Mohammad
    Abolmaesumi, Purang
    Rohling, Robert
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (10): : 2663 - 2676
  • [48] Closed-form distribution for soft differential detection in fast rice fading with diversity
    Corazza, GE
    EUROPEAN TRANSACTIONS ON TELECOMMUNICATIONS, 1998, 9 (01): : 33 - 36
  • [49] Closed-form Expression for Differential Phase Error Variance in Coherent Optical Systems
    Chen, Xi
    Al Amin, Abdullah
    Shieh, William
    2011 ASIA COMMUNICATIONS AND PHOTONICS CONFERENCE AND EXHIBITION (ACP), 2012,
  • [50] Novel closed-form equation for oscillation frequency range of differential ring oscillator
    Hazeri, Ali Reza
    Miar-Naimi, Hossein
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2018, 96 (01) : 117 - 123