Single Wall Closed-form Differential Ultrasound Calibration

被引:1
|
作者
Najafi, Mohammad [1 ]
Afsham, Narges [1 ]
Abolmaesumi, Purang [1 ]
Rohling, Robert [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
关键词
Free-hand ultrasound; calibration; single wall phantom; closed-form; differential; FREEHAND ULTRASOUND;
D O I
10.1117/12.911459
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In freehand 3D ultrasound, images are acquired while the position of the transducer is recorded with a tracking device. Calibration is essential in this technique to find the transformation from the image coordinates to the reference coordinate system. The single wall technique is a common calibration method because a simple plane phantom is used. Despite its advantages, such as ease of phantom construction and image analysis, this method requires large number of images to converge to the solution. One reason is a lack of a closed-form solution. Also, the technique uses slightly ill-conditioned sets of equations with a high condition number due to limited range of scanning motions that produce clear images of the plane. Here, a novel closed-form formulation has been proposed for the single wall calibration technique. Also, differential measurements of the plane image are used instead of absolute plane detection to improve accuracy. The closed-form solution leads to more accurate and robust results while providing an insight into understanding error propagation and finding the optimal set of transducer poses. Results have been compared to the conventional single wall technique. A residual error of 0.14 mm is achieved for the proposed method compared to 0.91 mm in the conventional approach.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Closed-Form Definite Integral
    Lossers, O. P.
    AMERICAN MATHEMATICAL MONTHLY, 2010, 117 (09): : 840 - 841
  • [32] CLOSED-FORM SOLUTIONS OF PERFORMABILITY
    MEYER, JF
    IEEE TRANSACTIONS ON COMPUTERS, 1982, 31 (07) : 648 - 657
  • [33] CLOSED-FORM IMPLICIT SUMMATION
    LUGER, AD
    ROBINSON, EJ
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (10): : 938 - &
  • [34] Closed-form solution for SPUDTs
    Danicki, Eugene J.
    Hickernell, Fred S.
    Mateescu, Irina
    2005 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXHIBITION, 2005, : 152 - 155
  • [35] CLOSED-FORM IMPLICIT SUMMATION
    LUGER, AD
    ROBINSON, EJ
    PHYSICS LETTERS A, 1970, A 31 (05) : 247 - &
  • [36] CLOSED-FORM SOLUTIONS FOR UNSTEADY MAGNETOHYDRODYNAMIC FLOW IN A POROUS MEDIUM WITH WALL TRANSPIRATION
    Abdulhameed, Mohammed
    Khan, Ilyas
    Khan, Arshad
    Shafie, Sharidan
    JOURNAL OF POROUS MEDIA, 2013, 16 (09) : 795 - 809
  • [37] Resolving the biophysics of axon transmembrane polarization in a single closed-form description
    Melendy, Robert F.
    JOURNAL OF APPLIED PHYSICS, 2015, 118 (24)
  • [38] Geometry-Based Camera Calibration Using Closed-Form Solution of Principal Line
    Chuang, Jen-Hui
    Ho, Chih-Hui
    Umam, Ardian
    Chen, Hsin-Yi
    Hwang, Jenq-Neng
    Chen, Tai-An
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2021, 30 : 2599 - 2610
  • [39] Closed-form Localization of a coherently distributed single source with circular array
    Jung, Tae-Jin
    Shin, Kee-Cheol
    Park, Gyu-Tae
    Cho, Sung-Il
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2018, 37 (06): : 437 - 442
  • [40] A fast closed-form solution for single-view pose determination
    John, Ben St.
    Madlmayr, Gerald
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, 2007, : 125 - 129