Single Wall Closed-form Differential Ultrasound Calibration

被引:1
|
作者
Najafi, Mohammad [1 ]
Afsham, Narges [1 ]
Abolmaesumi, Purang [1 ]
Rohling, Robert [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
关键词
Free-hand ultrasound; calibration; single wall phantom; closed-form; differential; FREEHAND ULTRASOUND;
D O I
10.1117/12.911459
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In freehand 3D ultrasound, images are acquired while the position of the transducer is recorded with a tracking device. Calibration is essential in this technique to find the transformation from the image coordinates to the reference coordinate system. The single wall technique is a common calibration method because a simple plane phantom is used. Despite its advantages, such as ease of phantom construction and image analysis, this method requires large number of images to converge to the solution. One reason is a lack of a closed-form solution. Also, the technique uses slightly ill-conditioned sets of equations with a high condition number due to limited range of scanning motions that produce clear images of the plane. Here, a novel closed-form formulation has been proposed for the single wall calibration technique. Also, differential measurements of the plane image are used instead of absolute plane detection to improve accuracy. The closed-form solution leads to more accurate and robust results while providing an insight into understanding error propagation and finding the optimal set of transducer poses. Results have been compared to the conventional single wall technique. A residual error of 0.14 mm is achieved for the proposed method compared to 0.91 mm in the conventional approach.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] A CLOSED-FORM DIFFERENTIAL FORMULATION FOR ULTRASOUND SPATIAL CALIBRATION: SINGLE WALL PHANTOM
    Najafi, Mohammad
    Afsham, Narges
    Abolmaesumi, Purang
    Rohling, Robert
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (04): : 1079 - 1094
  • [2] A CLOSED-FORM DIFFERENTIAL FORMULATION FOR ULTRASOUND SPATIAL CALIBRATION: MULTI-WEDGE PHANTOM
    Najafi, Mohammad
    Afsham, Narges
    Abolmaesumi, Purang
    Rohling, Robert
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (09): : 2231 - 2243
  • [3] A closed-form single-pose calibration method for the camera–projector system
    Zexi Feng
    Zhiquan Cheng
    Zhan Song
    Machine Vision and Applications, 2019, 30 : 461 - 472
  • [4] A closed-form single-pose calibration method for the camera-projector system
    Feng, Zexi
    Cheng, Zhiquan
    Song, Zhan
    MACHINE VISION AND APPLICATIONS, 2019, 30 (03) : 461 - 472
  • [5] Closed-Form Solutions to Differential Equations via Differential Evolution
    Mex, L.
    Cruz-Villar, Carlos A.
    Penunuri, F.
    DISCRETE DYNAMICS IN NATURE AND SOCIETY, 2015, 2015
  • [6] Single camera closed-form real-time needle trajectory tracking for ultrasound
    Najafi, Mohammad
    Rohling, Robert
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [7] A novel closed form solution for ultrasound calibration
    Boctor, E
    Viswanathan, A
    Choti, M
    Taylor, RH
    Fichtinger, G
    Hager, G
    2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, 2004, : 527 - 530
  • [8] A closed-form analytical model for single nanoshells
    Alam, Mehboob
    Massoud, Yehia
    IEEE TRANSACTIONS ON NANOTECHNOLOGY, 2006, 5 (03) : 265 - 272
  • [9] Closed-form calibration of the Gantry-Tau parallel robot
    Andreff, Nicolas
    Dressler, Isolde
    2008 IEEE/RSJ INTERNATIONAL CONFERENCE ON ROBOTS AND INTELLIGENT SYSTEMS, VOLS 1-3, CONFERENCE PROCEEDINGS, 2008, : 993 - 998
  • [10] CLOSED-FORM MATHEMATICAL SOLUTIONS TO SOME NETWORK ANALYZER CALIBRATION EQUATIONS
    KASA, I
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1974, IM23 (04) : 399 - 402