Evaluation of transvesical intra-abdominal pressure measurement in hospitalized dogs

被引:16
作者
Fetner, Melissa [1 ]
Prittie, Jennifer [1 ]
机构
[1] Anim Med Ctr, Emergency & Crit Care Dept, New York, NY 10065 USA
关键词
abdominal compartment syndrome; intra-abdominal hypertension; ABDOMINAL COMPARTMENT SYNDROME; CRITICALLY-ILL PATIENTS; INTERNATIONAL-CONFERENCE; CLINICAL EXAMINATION; HYPERTENSION; MANAGEMENT; DECOMPRESSION; EXPERTS; HORSES;
D O I
10.1111/j.1476-4431.2012.00725.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objectives - To (1) evaluate intra-abdominal pressure (IAP) measurements in dogs with possible risk factors for the development of intra-abdominal hypertension (IAH); (2) determine intra-observer variability of IAP measurements; and (3) determine interobserver variability of IAP measurements. Design - Prospective, observational, pilot study. Setting - Veterinary teaching hospital. Animals - Fourteen client-owned dogs, requiring urinary catheterization, admitted to the ICU. Interventions - Using the risk factors for IAH established for human patients as defined by the World Society of Abdominal Compartment Syndrome, dogs were assigned to either an IAH risk or no risk group. A commercially available IAP monitoring system was used to obtain 3 direct, transvesical IAP measurements. The primary investigator obtained the first 2 IAP measurements. A secondary investigator obtained the third IAP measurement. Measurements and Main Results - Dogs in the IAH risk group (n = 9/14) had significantly higher mean IAPs (9.4 +/- 3.4 mm Hg) than dogs in the no risk group (n = 5/14; 4.1 +/- 0.9 mm Hg) (P < 0.05). Measurements recorded by the primary investigator were compared to determine intra-observer variability. Pearson's correlation coefficient was 0.98 (P < 0.0001). Bland-Altman analysis determined a mean difference in IAP measurements of -0.3 mm Hg (95% confidence interval from 0.13 to -0.71 mm Hg) indicating an intra-observer variability of less than 0.8 mm Hg. Measurements recorded by the primary and secondary investigator were compared to determine interobserver variability. Pearson's correlation coefficient was 0.95 (P < 0.0001). Bland-Altman analysis determined a mean difference in IAP measurements of 0 mm Hg (95% confidence interval from 1.1 to -1.1 mm Hg) indicating an interobserver variability of less than 2.0 mm Hg. Conclusions - Dogs with predefined human risk factors for IAH had higher IAP than dogs without risk factors. IAP monitoring appears to have low variability within and across observers.
引用
收藏
页码:230 / 238
页数:9
相关论文
共 30 条
  • [1] Both primary and secondary abdominal compartment syndrome can be predicted early and are harbingers of multiple organ failure
    Balogh, Z
    McKinley, BA
    Holcomb, JB
    Miller, CC
    Cocanour, CS
    Kozar, RA
    Valdivia, A
    Ware, DN
    Moore, FA
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (05): : 848 - 859
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Intra-abdominal hypertension in two adult horses
    Brosnahan, Margaret M.
    Holbrook, Todd C.
    Gilliam, Lyndi L.
    Ritchey, Jerry W.
    Confer, Anthony W.
    [J]. JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2009, 19 (02) : 174 - 180
  • [4] Effects of abdominal decompression on cardiopulmonary function and visceral perfusion in patients with intra-abdominal hypertension
    Chang, MC
    Miller, PR
    D'Agostino, R
    Meredith, JW
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1998, 44 (03): : 440 - 445
  • [5] Results from the International Conference of Experts on Intra-Abdominal Hypertension and Abdominal Compartment Syndrome.: II.: Recommendations
    Cheatham, Michael L.
    Malbrain, Manu L. N. G.
    Kirkpatrick, Andrew
    Sugrue, Michael
    Parr, Michael
    De Waele, Jan
    Balogh, Zsolt
    Leppaeniemi, Ari
    Olvera, Claudia
    Ivatury, Rao
    D'Amours, Scott
    Wendon, Julia
    Hillman, Ken
    Wilmer, Alexander
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (06) : 951 - 962
  • [6] Is the evolving management of intra-abdominal hypertension and abdominal compartment syndrome improving survival?
    Cheatham, Michael L.
    Safcsak, Karen
    [J]. CRITICAL CARE MEDICINE, 2010, 38 (02) : 402 - 407
  • [7] Nonoperative Management of Intraabdominal Hypertension and Abdominal Compartment Syndrome
    Cheatham, Michael L.
    [J]. WORLD JOURNAL OF SURGERY, 2009, 33 (06) : 1116 - 1122
  • [8] The impact of body position on intra-abdominal pressure measurement: A multicenter analysis
    Cheatham, Michael L.
    De Waele, Jan J.
    De Laet, Inneke
    De Keulenaer, Bart
    Widder, Sandy
    Kirkpatrick, Andrew W.
    Cresswell, Adrian B.
    Malbrain, Manu
    Bodnar, Zsolt
    Mejia-Mantilla, Jorge H.
    Reis, Richard
    Parr, Michael
    Schulze, Robert
    Puig, Sonia
    [J]. CRITICAL CARE MEDICINE, 2009, 37 (07) : 2187 - 2190
  • [9] CLINICAL DETERMINATION OF PREOPERATIVE AND POSTOPERATIVE INTRAABDOMINAL PRESSURES IN DOGS
    CONZEMIUS, MG
    SAMMARCO, JL
    HOLT, DE
    SMITH, GK
    [J]. VETERINARY SURGERY, 1995, 24 (03) : 195 - 201
  • [10] The effect of neuromuscular blockers in patients with intra-abdominal hypertension
    De laet, Inneke
    Hoste, Eric
    Verholen, Emmanuel
    De Waele, Jan J.
    [J]. INTENSIVE CARE MEDICINE, 2007, 33 (10) : 1811 - 1814