High-resolution brain SPECT imaging by combination of parallel and tilted detector heads

被引:2
|
作者
Suzuki, Atsuro [1 ]
Takeuchi, Wataru [1 ]
Ishitsu, Takafumi [1 ]
Morimoto, Yuichi [1 ]
Kobashi, Keiji [1 ]
Ueno, Yuichiro [1 ]
机构
[1] Hitachi Ltd, Cent Res Lab, Hitachi, Ibaraki 3191221, Japan
关键词
Brain SPECT; Cadmium telluride (CdTe) detector; Collimator; COLLIMATOR; DISEASE; SYSTEM;
D O I
10.1007/s12149-015-0992-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To improve the spatial resolution of brain single-photon emission computed tomography (SPECT), we propose a new brain SPECT system in which the detector heads are tilted towards the rotation axis so that they are closer to the brain. In addition, parallel detector heads are used to obtain the complete projection data set. We evaluated this parallel and tilted detector head system (PT-SPECT) in simulations. In the simulation study, the tilt angle of the detector heads relative to the axis was 45A degrees. The distance from the collimator surface of the parallel detector heads to the axis was 130 mm. The distance from the collimator surface of the tilted detector heads to the origin on the axis was 110 mm. A CdTe semiconductor panel with a 1.4 mm detector pitch and a parallel-hole collimator were employed in both types of detector head. A line source phantom, cold-rod brain-shaped phantom, and cerebral blood flow phantom were evaluated. The projection data were generated by forward-projection of the phantom images using physics models, and Poisson noise at clinical levels was applied to the projection data. The ordered-subsets expectation maximization algorithm with physics models was used. We also evaluated conventional SPECT using four parallel detector heads for the sake of comparison. The evaluation of the line source phantom showed that the transaxial FWHM in the central slice for conventional SPECT ranged from 6.1 to 8.5 mm, while that for PT-SPECT ranged from 5.3 to 6.9 mm. The cold-rod brain-shaped phantom image showed that conventional SPECT could visualize up to 8-mm-diameter rods. By contrast, PT-SPECT could visualize up to 6-mm-diameter rods in upper slices of a cerebrum. The cerebral blood flow phantom image showed that the PT-SPECT system provided higher resolution at the thalamus and caudate nucleus as well as at the longitudinal fissure of the cerebrum compared with conventional SPECT. PT-SPECT provides improved image resolution at not only upper but also at central slices of the cerebrum.
引用
收藏
页码:682 / 696
页数:15
相关论文
共 50 条
  • [1] High-resolution brain SPECT imaging by combination of parallel and tilted detector heads
    Atsuro Suzuki
    Wataru Takeuchi
    Takafumi Ishitsu
    Yuichi Morimoto
    Keiji Kobashi
    Yuichiro Ueno
    Annals of Nuclear Medicine, 2015, 29 : 682 - 696
  • [2] High-Resolution Versus High-Sensitivity SPECT Imaging With Geometric Blurring Compensation for Various Parallel-Hole Collimation Geometries
    Zhang, Bin
    Zeng, Gengsheng L.
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (04): : 1121 - 1127
  • [3] Low-cost High-resolution Animal SPECT Imaging on a Clinical SPECT Scanner
    Dai, Tiantian
    Ma, Tianyu
    Liu, Hui
    Cui, Junjian
    Liu, Yaqiang
    Wei, Qingyang
    Wu, Jing
    Wang, Shi
    Jin, Yongjie
    2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, : 341 - 344
  • [4] Evaluation of a compact, high-resolution SPECT detector based on digital silicon photomultipliers
    Bouckaert, Carmen
    Vandenberghe, Stefaan
    Van Holen, Roel
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (23): : 7521 - 7539
  • [5] A high resolution SPECT detector based on thin continuous LYSO
    Deprez, Karel
    Van Holen, Roel
    Vandenberghe, Stefaan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (01): : 153 - 171
  • [6] Comparison of Pinhole and High-Resolution Parallel-Hole Imaging for Nodular Thyroid Disease
    Ghanem, Mohammad A.
    Elgazzar, Abdelhamid H.
    Elsaid, Mohammad M.
    Shehab, Fatima
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (09) : 770 - 771
  • [7] Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging
    Zeraatkar, Navid
    Kalluri, Kesava S.
    Auer, Benjamin
    Konik, Arda
    Fromme, Timothy J.
    Furenlid, Lars R.
    Kuo, Phillip H.
    King, Michael A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (12) : 4209 - 4224
  • [8] Combination of Converging Collimators for High-Sensitivity Brain SPECT
    Ter-Antonyan, Ruben
    Jaszczak, Ronald J.
    Greer, Kim L.
    Bowsher, James E.
    Metzler, Scott D.
    Coleman, R. Edward
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (09) : 1548 - 1556
  • [9] Design of a high resolution scintillator based SPECT detector (SPECTatress)
    Deprez, Karel
    Van Holen, Roel
    Vandenberghe, Stefaan
    Staelens, Steven
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S107 - S110
  • [10] High-resolution mechanical imaging of the kidney
    Streitberger, Kaspar-Josche
    Guo, Jing
    Tzschaetzsch, Heiko
    Hirsch, Sebastian
    Fischer, Thomas
    Braun, Juergen
    Sack, Ingolf
    JOURNAL OF BIOMECHANICS, 2014, 47 (03) : 639 - 644