A prospective, multicenter, single-arm clinical trial cohort to evaluate the safety and effectiveness of a novel stent graft system (WeFlow-JAAA) for the treatment of juxtarenal abdominal aortic aneurysm: A study protocol

被引:2
作者
Gao, Jiang-Ping [1 ,2 ]
Zhang, Hong-Peng [1 ]
Jia, Xin [1 ]
Xiong, Jiang [1 ]
Ma, Xiao-Hui [1 ]
Wang, Li-Jun [1 ]
Zhang, Min-Hong [1 ]
Xu, Yong-Le [1 ]
Guo, Wei [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Vasc Surg, Beijing, Peoples R China
[2] Chinese PLA, Med Sch, Beijing, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2022年 / 9卷
关键词
abdominal aortic aneurysm; juxtarenal; endovascular aortic repair; endovascular repair; WeFlow-JAAA; OFF-THE-SHELF; FENESTRATED ENDOVASCULAR GRAFT; REPAIR; RUPTURE;
D O I
10.3389/fcvm.2022.1013834
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Juxtarenal abdominal aortic aneurysms (JRAAAs) are challenging to cure by traditional endovascular aortic repair (EVAR). Due to the inherent disadvantages of the customized fenestrated and/or branched aortic endografts (such as delayed cycles with a risk of aneurysm rupture, unavailable in emergency or confine operations), several off-the-shelf devices have been developed for the treatment of JRAAA. However, these devices being used in clinical trials have been proven to have a non-negligible risk of reintervention and inadequate anatomic applicability. We have developed a new off-the-shelf aortic endograft system (WeFlow-JAAA) with a mixed design of inner branches and modified fenestrations. The purpose of this cohort study is to assess the safety and effectiveness of the innovative aortic endograft system. Methods and analysis: This is a prospective, multicenter, single-armed clinical trial cohort study. The enrolment will take place in 29 centers in China, and 106 adult patients with JRAAA will be enrolled in total. Clinical information and CT angiography (CTA) images will be collected and recorded. Patients will be followed up for 5 years. The primary safety endpoint is the rate of no major adverse event within 30 days after index EVAR. The primary efficacy endpoint is the rate of immediate technical success and no JRAAA-related reintervention within 12 months after the procedure.
引用
收藏
页数:9
相关论文
共 12 条
  • [1] Belczak SQ, 2014, CLINICS, V69, P641
  • [2] de Niet A, 2020, ENDOVASCULAR APPROAC
  • [3] "Off-the-shelf" devices for complex aortic aneurysm repair
    Farber, Mark A.
    Vallabhaneni, Raghuveer
    Marston, William A.
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (03) : 579 - 583
  • [4] The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft
    Gallitto, Enrico
    Faggioli, Gianluca
    Spath, Paolo
    Pini, Rodolfo
    Mascoli, Chiara
    Ancetti, Stefano
    Stella, Andrea
    Abualhin, Mohammhed
    Gargiulo, Mauro
    [J]. JOURNAL OF VASCULAR SURGERY, 2020, 72 (01) : 16 - 24
  • [5] Systematic Review of Off-the-Shelf or Physician-Modified Fenestrated and Branched Endografts
    Georgiadis, George S.
    van Herwaarden, Joost A.
    Antoniou, George A.
    Hazenberg, Constantijn E. V. B.
    Giannoukas, Athanasios D.
    Lazarides, Miltos K.
    Moll, Frans L.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2016, 23 (01) : 98 - 109
  • [6] Meta-analysis of fenestrated endovascular aneurysm repair versus open surgical repair of juxtarenal abdominal aortic aneurysms over the last 10 years
    Jones, A. D.
    Waduud, M. A.
    Walker, P.
    Stocken, D.
    Bailey, M. A.
    Scott, D. J. A.
    [J]. BJS OPEN, 2019, 3 (05): : 572 - 584
  • [7] Aneurysm Rupture and Mortality During the Waiting Time for a Customised Fenestrated/Branched Stent Graft in Complex Endovascular Aortic Repair
    Katsargyris, Athanasios
    Uthayakumar, Vasuki
    de Marino, Pablo Marques
    Botos, Balazs
    Verhoeven, Eric L.
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2020, 60 (01) : 44 - 48
  • [8] Results of the United States multicenter prospective study evaluating the Zenith fenestrated endovascular graft for treatment of juxtarenal abdominal aortic aneurysms
    Oderich, Gustavo S.
    Greenberg, Roy K.
    Farber, Mark
    Lyden, Sean
    Sanchez, Luis
    Fairman, Ron
    Jia, Feiyi
    Bharadwaj, Priya
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 60 (06) : 1420 - U392
  • [9] The compatibility of p-branch "off-the-shelf" fenestrated endovascular graft in Asian patients with juxtarenal aortic aneurysm
    Ou, Jiale
    Cheng, Stephen W. K.
    Chan, Yiu Che
    [J]. JOURNAL OF VASCULAR SURGERY, 2015, 61 (06) : 1417 - 1423
  • [10] Prospective, multicenter experience with the Ventana Fenestrated System for juxtarenal and pararenal aortic aneurysm endovascular repair
    Quinones-Baldrich, William J.
    Holden, Andrew
    Mertens, Renato
    Thompson, Matt M.
    Sawchuk, Alan P.
    Becquemin, Jean-Pierre
    Eagleton, Matthew
    Clair, Daniel G.
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 58 (01) : 1 - 9