Modified Implant Surface with Slower and Less Initial Biofilm Formation

被引:39
作者
John, Gordon [1 ]
Becker, Juergen [1 ]
Schwarz, Frank [1 ]
机构
[1] Univ Dusseldorf, Westdeutsch Kieferklin, Dept Oral Surg, D-40225 Dusseldorf, NW, Germany
关键词
implant; implant surface; peri-implantitis; titanium; EARLY PLAQUE-FORMATION; SOFT-TISSUE REACTIONS; IN-VIVO; PERI-IMPLANTITIS; DENTAL IMPLANTS; FREE-ENERGY; TITANIUM; ROUGHNESS; COLONIZATION; TOPOGRAPHY;
D O I
10.1111/cid.12140
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
BackgroundPeri-implant mucositis and peri-implantitis are a raising issue in dental implantology. Peri-implant infections are mainly caused by the formation of biofilm. Different surface textures exhibit various conditions for biofilm formation resulting in several speed of maturation and development. Materials and MethodsOn three different titanium implant surfaces, machined-surface (M), sandblasted large grit, and acid-etched surface (SLA) and machined-modified acid-etched surface (mod MA) initial biofilms were collected. Plaque formation was investigated by erythrosine staining and energy-dispersive X-ray spectroscopy (EDX). For testing the biocompatibility of these plaque-settled surfaces, autoclaved specimens were settled with human gingival fibroblasts, and cell viability was tested. ResultsThe mean initial plaque surface was detected in the following descending order: M>SLA>mod MA. The differences between these groups were significant. The highest cell viability was detected in the M groups, whereas mod MA and SLA showed comparable results. The results of initial biofilm formation were proved by EDX. ConclusionsWithin the limitations of this study, conclusion can be made that mod MA surface shows significant slower initial biofilm formation which could be an advantage in initial transgingival healing process and also an easement for oral hygiene of patients because maturation of plaque is retarded, and immature biofilms are easier to remove.
引用
收藏
页码:461 / 468
页数:8
相关论文
共 42 条
[1]  
Abrahamsson I, 1998, CLIN ORAL IMPLAN RES, V9, P73
[2]   Spontaneous progression of ligature induced peri-implantitis at implants with different surface roughness: an experimental study in dogs [J].
Berglundh, T. ;
Gotfredsen, K. ;
Zitzmann, N. U. ;
Lang, N. P. ;
Lindhe, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (05) :655-661
[3]  
Berglundh T, 1992, Clin Oral Implants Res, V3, P1, DOI 10.1034/j.1600-0501.1992.030101.x
[4]   Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature [J].
Bollen, CML ;
Lambrechts, P ;
Quirynen, M .
DENTAL MATERIALS, 1997, 13 (04) :258-269
[5]   SOFT-TISSUE REACTIONS TO NON-SUBMERGED UNLOADED TITANIUM IMPLANTS IN BEAGLE DOGS [J].
BUSER, D ;
WEBER, HP ;
DONATH, K ;
FIORELLINI, JP ;
PAQUETTE, DW ;
WILLIAMS, RC .
JOURNAL OF PERIODONTOLOGY, 1992, 63 (03) :225-236
[6]   Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[7]   Bacterial colonization immediately after installation on oral titanium implants [J].
Fuerst, Mirjam M. ;
Salvi, Giovanni E. ;
Lang, Niklaus P. ;
Persson, G. Rutger .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (04) :501-508
[8]  
Glantz P.O., 1969, Odontol Revy, V20, P1
[9]  
Hahn R, 1992, DTSCH ZAHNARZTL Z, V47, P330
[10]   Peri-implant diseases: diagnosis and risk indicators [J].
Heitz-Mayfield, Lisa J. A. .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :292-304