The success of knee arthroplasty is dependent on many factors. Postoperative extremity and component alignment are important determinants of outcome and longevity. Malalignment (> 3 degrees) results in higher failure rates. Computer-assisted navigation devices were developed to improve implant positioning. This study evaluated the early outcomes of a high-volume fellowship-trained surgeon relative to component positioning and limb alignment using an image-free navigation system. The navigation group consisted of 116 consecutive patients, and the conventional group consisted of 51 consecutive patients. The postoperative mechanical axis was within 3 degrees of neutral mechanical alignment in 95% of the navigation cases vs 84% of the conventional cases (P < .02). The range of the alignment and component position measurements narrowed, and the undesired outliers decreased. Accuracy was improved with navigation. Navigation was a viable device to improve the Outcome of total knee arthroplasty relative to limb and component alignment.
引用
收藏
页码:132 / 138
页数:7
相关论文
共 23 条
  • [1] Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty
    Bäthis, H
    Perlick, L
    Tingart, M
    Lüring, C
    Perlick, C
    Grifka, J
    [J]. INTERNATIONAL ORTHOPAEDICS, 2004, 28 (02) : 87 - 90
  • [2] Alignment in total knee arthroplasty -: A comparison of computer-assisted surgery with the conventional technique
    Bäthis, H
    Perlick, L
    Tingart, M
    Lüring, C
    Zurakowski, D
    Grifka, J
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (05): : 682 - 687
  • [3] Tibial component failure mechanisms in total knee arthroplasty
    Berend, ME
    Ritter, MA
    Meding, JB
    Faris, PM
    Keating, EM
    Redelman, R
    Faris, GW
    Davis, KE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (428) : 26 - 34
  • [4] CATES HE, 1993, CLIN ORTHOP RELAT R, P32
  • [5] DORR LD, 1997, CLIN ORTHOP RELAT R, V205, P5
  • [6] Engh G A, 1990, J Arthroplasty, V5, P1, DOI 10.1016/S0883-5403(06)80002-1
  • [7] Total knee arthroplasty implanted with and without kinematic navigation
    Hart, R
    Janecek, M
    Chaker, A
    Bucek, P
    [J]. INTERNATIONAL ORTHOPAEDICS, 2003, 27 (06) : 366 - 369
  • [8] INSALL JN, 1985, CLIN ORTHOP RELAT R, P13
  • [9] CORONAL ALIGNMENT AFTER TOTAL KNEE REPLACEMENT
    JEFFERY, RS
    MORRIS, RW
    DENHAM, RA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (05): : 709 - 714
  • [10] JIANG CC, 1989, CLIN ORTHOP RELAT R, P50