Flow-injection determination of cysteine in pharmaceuticals based on luminol-persulphate chemiluminescence detection

被引:43
作者
Waseem, Amir [1 ]
Yaqoob, Mohammad [1 ]
Nabi, Abdul [1 ]
机构
[1] Univ Baluchistan, Dept Chem, Quetta, Pakistan
关键词
flow-injection analysis; chemiluminescence; cysteine; acetylcysteine; glutathione; pharmaceuticals;
D O I
10.1002/bio.1024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection (FI) method is reported for the determination Of L-cysteine, based on its enhancement on chemiluminescence (CL) emission of luminol oxidized by sodium persulphate in alkaline solution. The calibration graph was linear over the range 1.0 x 10(-9)-5.0 x 10(-7) mol/L (r(2) = 0.9992), with relative standard deviations (RSDs) in the range 1.1-2.3% (n = 4). The limit of detection (3 sigma blank) was 5.0 x 10(-10) mol/L with a sample throughput of 120/h. The method was applied to pharmaceuticals and the results obtained were in reasonable agreement with the amount labelled. The proposed method was also applied to cysteine in synthetic amino acid mixtures. Calibration graphs of N-acetylcysteine and glutathione over the range 1.0-50 x 10(-8) and 0.5-7.5 x 10(-7) mol/L were also established (r(2) = 0.998 and 0.9986) with RSDs in the range 1.0-2.0% (n = 4), and the limits of detection (3 sigma blank) were 5.0 x 10(-9) and 1.0 x 10(-8) mol/L, respectively. Copyright (C) 2008 John Wiley & Sons, Ltd.
引用
收藏
页码:144 / 149
页数:6
相关论文
共 40 条
[1]   Spectrophotometric determination of cysteine and N-acetylcysteine in pharmaceutical preparations [J].
Abu Eid, M .
MIKROCHIMICA ACTA, 1998, 129 (1-2) :91-95
[2]   Cobalt(II) salophen-modified carbon-paste electrode for potentiometric and voltammetric determination of cysteine [J].
Amini, MK ;
Khorasani, JH ;
Khaloo, SS ;
Tangestaninejad, S .
ANALYTICAL BIOCHEMISTRY, 2003, 320 (01) :32-38
[3]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF URINARY CYSTEINE AND CYSTINE [J].
BIRWE, H ;
HESSE, A .
CLINICA CHIMICA ACTA, 1991, 199 (01) :33-42
[4]   Use of pH gradients in continuous-flow systems and multivariate regression techniques applied to the determination of methionine and cysteine in pharmaceuticals [J].
Blasco, F ;
MedinaHernandez, MJ ;
Sagrado, S .
ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) :151-159
[5]   Ionization-reactivity relationships for cysteine thiols in polypeptides [J].
Bulaj, G ;
Kortemme, T ;
Goldenberg, DP .
BIOCHEMISTRY, 1998, 37 (25) :8965-8972
[6]  
Daskalakis I, 1996, BIOMED CHROMATOGR, V10, P205, DOI 10.1002/(SICI)1099-0801(199609)10:5<205::AID-BMC589>3.3.CO
[7]  
2-G
[8]   Investigation on the chemiluminescence reaction of luminol-H2O2-S2-/R-SH system [J].
Du, JX ;
Li, YH ;
Lu, JR .
ANALYTICA CHIMICA ACTA, 2001, 448 (1-2) :79-83
[9]   Analytical applications of flow injection with chemiluminescence detection - a review [J].
Fletcher, P ;
Andrew, KN ;
Calokerinos, AC ;
Forbes, S ;
Worsfold, PJ .
LUMINESCENCE, 2001, 16 (01) :1-23
[10]  
Garcia-Campana A. M., 2001, CHEMILUMINESCENCE AN