Effective determination of trace residues of glibenclamide in urine samples using dispersive micro solid-phase extraction and its final detection by chromatographic analysis

被引:13
作者
Eilami, Owrang [1 ]
Asfaram, Arash [2 ]
Ghaedi, Mehrorang [3 ]
Goudarzi, Alireza [4 ]
机构
[1] Yasuj Univ Med Sci, Coll Med, Dept Infect Dis & Trop Med, Yasuj, Iran
[2] Yasuj Univ Med Sci, Med Plants Res Ctr, Yasuj, Iran
[3] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[4] Golestan Univ, Dept Polymer Engn, Gorgan 4918888369, Iran
关键词
LIQUID-LIQUID MICROEXTRACTION; MOLECULARLY IMPRINTED POLYMER; QUANTITATIVE-DETERMINATION; HUMAN PLASMA; HPLC METHOD; PRECONCENTRATION; NANOPARTICLES; WATER; GLIMEPIRIDE; ADSORPTION;
D O I
10.1039/c8ay01965g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical procedure for rapid and effective dispersive micro-solid-phase extraction (DMSPE) of glibenclamide (GB) from urine samples was set up by using sulfur doped tin oxide nanoparticles (S@ SnO2-NPs) loaded on activated carbon (AC), as the sorbent, and clean-up materials, followed by detection. The main experimental parameters affecting the extraction efficiency for GB were assessed and optimized. The maximum recovery of GB predicted by optimization plots was 98.86%, obtained with 15 mL of water, 250 mL of methanol (as an eluent), pH 8.0, 25 mg of S@ SnO2-NPs-AC, and an extraction time of 2.5 min. Our results indicated that under these optimized extraction conditions, determination coefficients (R-2) of the calibration curves in the range of 0.60-5500 mg L-1 were > 0.991, detection limits (signal-to-noise ratio = 3) were in the range of 0.09-0.16 mg L-1, the average recoveries of spiked GB in urine samples were 95.73-105.50%, and assessed relative standard deviations (RSDs, %) were between 1.15 and 6.84%. The results also demonstrated that the presented method could be suitable for the determination of trace residues of GB in urine samples.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
  • [41] Magnetic Dispersive Solid-Phase Extraction Using Toner Powder for Trace Determination of Heavy Metals in Vegetables and Aqueous Media by FAAS: Box-Behnken Design
    Mahmoudian, Masoumeh
    Sarrafi, Amir Hossein Mohsen
    Konoz, Elaheh
    Niazi, Ali
    CHEMISTRYSELECT, 2022, 7 (48):
  • [42] Simultaneous determination of four antibiotics in human urine and hair samples employing a simple and efficient dispersive micro solid-phase extraction-high performance liquid chromatography
    Soleimanirad, Ehsan
    Badameh, Anousheh
    Raoufi, Arastou
    Ebrahimi, Mahmoud
    PHARMACOLOGICAL REPORTS, 2022, 74 (05) : 1069 - 1082
  • [43] Zinc ferrite as a magnetic sorbent for the dispersive micro solid-phase extraction of sulfonamides and their determination by HPLC
    Chatzimitakos, Theodoros
    Stalikas, Constantine
    MICROCHEMICAL JOURNAL, 2020, 155
  • [44] Solid-Phase Extraction and Detection by Digital Image Directly in the Sorbent: Determination of Nickel in Environmental Samples
    Santos, Luana Bastos
    Barreto, Jeferson Alves
    dos Santos de Assis, Rosivan
    de Souza, Cheilane Tavares
    Ferreira, Sergio Luis Costa
    Novaes, Cleber Galvao
    Lemos, Valfredo Azevedo
    WATER AIR AND SOIL POLLUTION, 2020, 231 (09)
  • [45] MCM-41 based dispersive micro-solid phase extraction of selected cephalosporin antibiotic residues from water samples prior to liquid chromatographic quantification
    Bangani, Andisiwe
    Mnguni, Mthokozisi
    Makhetha, Thollwana Andretta
    Oliveira, Elisabete
    Capelo-Martinez, Jose Luis
    Lodeiro, Carlos
    Nomngongo, Philiswa Nosizo
    TALANTA OPEN, 2024, 10
  • [46] Determination of four bisphenols in water and urine samples by magnetic dispersive solid-phase extraction using a modified zeolite/iron oxide composite prior to liquid chromatography diode array detection
    Baile, Paola
    Medina, Juan
    Vidal, Lorena
    Canals, Antonio
    JOURNAL OF SEPARATION SCIENCE, 2020, 43 (9-10) : 1808 - 1816
  • [47] Dispersive Micro Solid-Phase Extraction Using Multiwalled Carbon Nanotubes for Simultaneous Determination of Trace Metal Ions by Energy-Dispersive X-ray Fluorescence Spectrometry
    Skorek, Robert
    Zawisza, Beata
    Margui, Eva
    Queralt, Ignasi
    Sitko, Rafal
    APPLIED SPECTROSCOPY, 2013, 67 (02) : 204 - 209
  • [48] Development of dispersive liquid-liquid micro-extraction procedure for trace determination of pesticide diazinon in urine samples
    Sabet, Maryam Ramin
    Pourhossein, Mehran
    Khadem, Monireh
    Omidi, Fariborz
    Golbabaei, Farideh
    Shahtaheri, Seyed Jamaleddin
    JOURNAL OF HEALTH AND SAFETY AT WORK, 2019, 8 (04) : 359 - +
  • [49] Development of a new solvent-assisted dispersive solid-phase extraction followed by ion mobility spectrometry for trace determination of organophosphorus pesticides in environmental water samples
    Aladaghlo, Zolfaghar
    Fakhari, Ali Reza
    SEPARATION SCIENCE PLUS, 2019, 2 (08) : 291 - 299
  • [50] Simultaneous determination of trace amounts of anti-hypertensive drugs in urine using magnetic mixed hemimicelles solid-phase extraction combined with HPLC-UV
    Maham, Mehdi
    Sharifabadi, Malihe Khoeini
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (03) : 302 - 309