FEASIBILITY OF PERCUTANEOUS CONTRAST ULTRASOUND-GUIDED CHOLECYSTOGRAPHY IN DOGS

被引:5
作者
Ji, Seoyeoun [1 ]
Jung, Sunyoung [1 ]
Kim, Boeun [1 ]
Jung, Joohyun [1 ]
Yoon, Junghee [1 ]
Choi, Mincheol [1 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Med Imaging, Seoul 151742, South Korea
关键词
percutaneous ultrasound-guided cholecystography; SonoVue; ultrasound contrast agent; ENHANCED-ULTRASOUND; BILE-DUCT; OBSTRUCTION; DIAGNOSIS; JAUNDICE; CHOLANGIOGRAPHY; ULTRASONOGRAPHY; SURGERY;
D O I
10.1111/vru.12224
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Differentiating hepatocellular disease versus biliary obstruction can be challenging in dogs presented for icterus. The purpose of this prospective study was to determine the feasibility of percutaneous contrast ultrasound-guided cholecystography in dogs. Ten normal dogs weighing 7.6-13.0 kg (median 9.8 kg) were recruited. All dogs were considered normal based on complete blood count, serum chemistry profile, ultrasound examination, and percutaneous radiographic cholecystography. Percutaneous contrast ultrasound-guided cholecystography was performed using 0.5 ml of commercially available contrast agent and two conventional ultrasound machines for simultaneous scanning at two different locations. Two observers independently evaluated the time to initial detection of contrast in the proximal duodenum and duration of contrast enhancement via visual monitoring. Dynamic contrast enhancement was calculated using time-intensity curves. Mean (+/- SD) and median (range) of time to initial detection were 8.60 s (+/- 3.35) and 8.0 s (2.0-11.0), respectively, and mean and median duration were 50.45 s (+/- 23.24) and 53.0 s (20.0 - 70.0), respectively. Mean, median, and range of peak intensity were 114.1 mean pixel value (MPV) (SD +/- 30.7), 109.2 MPV, and 79.7-166.7, respectively, and mean, median, and range of time to peak intensity were 26.1 s (SD +/- 7.1 s), 24.0 s, and 19.0-41.0 s, respectively. Findings indicated that percutaneous contrast ultrasound-guided cholecystography is a feasible technique for detecting and quantifying patency of the bile duct in normal dogs. Future studies are needed to assess the diagnostic utility of this technique for dogs with biliary obstruction.
引用
收藏
页码:296 / 300
页数:5
相关论文
共 50 条
[31]   Feasibility and safety of ultrasound-guided caudal epidural glucocorticoid injections [J].
Blanchais, Anne ;
Le Goff, Benoit ;
Guillot, Pascale ;
Berthelot, Jean-Marie ;
Glemarec, Joelle ;
Maugars, Yves .
JOINT BONE SPINE, 2010, 77 (05) :440-444
[32]   ENDOSCOPIC ULTRASOUND-GUIDED CHOLEDOCHODUODENOSTOMY [J].
Hara, Kazuo ;
Yamao, Kenji ;
Mizuno, Nobumasa ;
Sawaki, Akira ;
Takagi, Tadayuki ;
Bhatia, Vikram .
DIGESTIVE ENDOSCOPY, 2010, 22 (02) :147-150
[33]   Feasibility of quantitative contrast ultrasound imaging of bladder tumors in dogs [J].
Pollard, Rachel E. ;
Watson, Katherine D. ;
Hu, Xiaowen ;
Ingham, Elizabeth ;
Ferrara, Katherine W. .
CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2017, 58 (01) :70-72
[34]   Ultrasound-guided percutaneous injection of methylene blue to identify nerve pathology and guide surgery [J].
Osorio, Joseph A. ;
Breshears, Jonathan D. ;
Arnaout, Omar ;
Simon, Neil G. ;
Hastings-Robinson, Ashley M. ;
Aleshi, Pedram ;
Kliot, Michel .
NEUROSURGICAL FOCUS, 2015, 39 (03)
[35]   Percutaneous ultrasound-guided laser ablation for the treatment of cervical tuberculous lymphadenitis: a pilot study [J].
Yang, Gaoyi ;
Fang, Jianhua ;
Yu, Tianzhuo ;
Zhang, Ying ;
Zhang, Wenzhi ;
Zhao, Dan ;
Xu, Jianping ;
Wang, Caifen .
JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (04) :1512-1520
[36]   Contrast-Enhanced Harmonic Endoscopic Ultrasound-Guided Puncture for the Patients with Pancreatic Masses [J].
Otsuka, Yasuo ;
Kamata, Ken ;
Kudo, Masatoshi .
DIAGNOSTICS, 2023, 13 (06)
[37]   Computer-Tomographic Verification of Ultrasound-Guided Piriformis Muscle Injection: A Feasibility Study [J].
Fabregat, Gustavo ;
Rosello, Marta ;
Asensio-Samper, Juan M. ;
Villanueva-Perez, Vicente L. ;
Martinez-Sanjuan, Vicente ;
De Andres, Jose ;
Eichenberger, Urs .
PAIN PHYSICIAN, 2014, 17 (06) :507-513
[38]   FEASIBILITY AND USEFULNESS OF INTRA-CAVITARY CONTRAST-ENHANCED ULTRASOUND IN PERCUTANEOUS NEPHROSTOMY [J].
Cui, Xin-Wu ;
Ignee, Andre ;
Maros, Tiberius ;
Straub, Bernd ;
Wen, Jian-Guo ;
Dietrich, Christoph F. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09) :2180-2188
[39]   Percutaneous Ultrasound-Guided Laser Ablation with Contrast-Enhanced Ultrasonography for Hyperfunctioning Parathyroid Adenoma: A Preliminary Case Series [J].
Jiang, Tianan ;
Chen, Fen ;
Zhou, Xiang ;
Hu, Ying ;
Zhao, Qiyu .
INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2015, 2015
[40]   Ultrasound-Guided Percutaneous Laser Ablation of Papillary Thyroid Microcarcinoma: A Feasibility Study on Three Cases with Pathological and Immunohistochemical Evaluation [J].
Valcavi, Roberto ;
Piana, Simonetta ;
Bortolan, Giorgio Stecconi ;
Lai, Roberta ;
Barbieri, Verter ;
Negro, Roberto .
THYROID, 2013, 23 (12) :1578-1582