Influence of nitrogen on the degradation of toluene in a compost-based biofilter

被引:29
作者
Delhoménie, MC
Bibeau, L
Roy, S
Brzezinski, R
Heitz, M
机构
[1] Univ Sherbrooke, Fac Engn, Dept Chem Engn, Sherbrooke, PQ J1K 2R1, Canada
[2] Univ Sherbrooke, Fac Sci, Dept Biol, Sherbrooke, PQ J1K 2R1, Canada
关键词
biofiltration; toluene; air; treatment; compost; nitrogen; urea;
D O I
10.1002/jctb.472
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Two identical laboratory-scale bioreactors were operated simultaneously, each treating an input air flow rate of 1 m(3) h(-1). The biofilters consisted of multi-stage columns, each stage packed with a compost-based filtering material, which was not previously inoculated. The toluene inlet concentration was fixed at 1.5 g m(-3) of air. Apart from the necessary carbon, the elements nitrogen, phosphorus, sulfur, potassium and other micro-elements are also essential for microbial metabolism. These were distributed throughout the filter bed material by periodic 'irrigations' with various test nutrient solutions. The performance of each biofilter was quantified by determining its toluene removal efficiency, and elimination capacity. Nutrient solution nitrogen levels were varied from 0 to 6.0 g dm(-3), which led to elimination capacities of up to 50 g m(-3) h(-1) being obtained for a toluene inlet load of 80 g m(-3) h(-1). A theoretical analysis also confirmed that the optimum nitrogen solution concentration lays in the range 4.0-6.0 g dm(-3). Validation of the irrigation mode was achieved by watering each biofilter stage individually. Vertical stage-by-stage stratification of the biofilter performance was not detected, ie each filter bed section removed the same amount of pollutant, the elimination capacity per stage being about 16 g m(-3) h(-1) per section of column. (C) 2001 Society of Chemical Industry.
引用
收藏
页码:997 / 1006
页数:10
相关论文
共 28 条
[1]  
ALEXANDER M, 1994, BIODEGRADATION BIORE, P199
[2]  
ALONSO C, 1997, P BATT MEM I 4 INT I, V5, P205
[3]   Treatment of air polluted with xylenes using a biofilter reactor [J].
Bibeau, L ;
Kiared, K ;
Brzezinski, R ;
Viel, G ;
Heitz, M .
WATER AIR AND SOIL POLLUTION, 2000, 118 (3-4) :377-393
[4]   Biofiltration of BTEX: Media, substrate, and loadings effects [J].
Corsi, RL ;
Seed, L .
ENVIRONMENTAL PROGRESS, 1995, 14 (03) :151-158
[5]   Biological waste air treatment in biotrickling filters [J].
Cox, HHJ ;
Deshusses, MA .
CURRENT OPINION IN BIOTECHNOLOGY, 1998, 9 (03) :256-262
[6]  
DEVINNY JS, 1999, BIOFILTRATION AIR PO, P94
[7]  
*GOUV CAN, 1992, 4 GOUV CAN ENV CAN
[8]   Biofiltration of air contaminated by styrene: Effect of nitrogen supply, gas flow rate, and inlet concentration [J].
Jorio, H ;
Bibeau, L ;
Heitz, M .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) :1764-1771
[9]   Biofiltration of air [J].
Jorio, H ;
Heitz, M .
CANADIAN JOURNAL OF CIVIL ENGINEERING, 1999, 26 (04) :402-424
[10]  
KELLNER C, 1998, P 91 ANN M EXH AIR W, P1