Influence of household air-conditioning use modes on the energy performance of residential district cooling systems

被引:67
作者
Zhou, Xin [1 ]
Yan, Da [2 ]
Feng, Xiaohang [2 ]
Deng, Guangwei [3 ]
Jian, Yiwen [4 ]
Jiang, Yi [2 ]
机构
[1] Southeast Univ, Sch Architecture, Nanjing 210096, Jiangsu, Peoples R China
[2] Tsinghua Univ, Sch Architecture, Beijing 100084, Peoples R China
[3] Shanghai Res Inst, Bldg Sci Grp, Shanghai 610041, Peoples R China
[4] Beijing Univ Technol, Beijing 100084, Peoples R China
关键词
AC usage model; load distribution; residential district cooling system; uncertainty analysis; energy performance; THERMAL COMFORT; OCCUPANT BEHAVIOR; SIMULATION; EFFICIENCY; CONSUMPTION; BUILDINGS; DEST; OPTIMIZATION; VERIFICATION; METHODOLOGY;
D O I
10.1007/s12273-016-0280-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
During technical evaluations of cooling systems in residential buildings, it is necessary to consider the influence of the household air-conditioning (AC) use modes. In other words, how the occupants control the AC, for instance, when it is turned on, what the temperature setting is, and how long it is used. Field measurements and spot interviews indicate that AC usage by residents should be environmental, event and random related. A reduced-order AC conditional probability (CP) model was developed in this study to describe AC usage. The AC CP model was integrated with a building energy modeling program (BEMP) to reflect the interaction of the AC operation and the indoor environment. With consideration of stochastic AC use modes, the uncertainty of user compositions was studied. Additionally, simulation results revealed that AC use modes and user compositions can cause up to a 4.5-fold difference in the system efficiency of district cooling systems. The Lorenz curve and Gini coefficient were applied in this study to describe the load distribution in a quantitative manner. Through a comparison with the constant schedule definition model, the study also identified inclusion of the stochastic feature of AC use modes and their compositions in simulations as being important to the technical evaluation of district cooling systems.
引用
收藏
页码:429 / 441
页数:13
相关论文
共 58 条
[11]   Applying district-cooling technology in Hong Kong [J].
Chow, TT ;
Au, WH ;
Yau, R ;
Cheng, V ;
Chan, A ;
Fong, KF .
APPLIED ENERGY, 2004, 79 (03) :275-289
[12]   Energy modelling of district cooling system for new urban development [J].
Chow, TT ;
Fong, KF ;
Chan, ALS ;
Yau, R ;
Au, WH ;
Cheng, V .
ENERGY AND BUILDINGS, 2004, 36 (11) :1153-1162
[13]   Building-mix optimization in district-cooling system implementation [J].
Chow, TT ;
Chan, ALS ;
Song, CL .
APPLIED ENERGY, 2004, 77 (01) :1-13
[14]   Occupancy schedules learning process through a data mining framework [J].
D'Oca, Simona ;
Hong, Tianzhen .
ENERGY AND BUILDINGS, 2015, 88 :395-408
[15]   Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 [J].
de Dear, RJ ;
Brager, GS .
ENERGY AND BUILDINGS, 2002, 34 (06) :549-561
[16]   Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner [J].
Devotta, S ;
Padalkar, AS ;
Sane, NK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (04) :594-604
[17]  
Fanger PO, 1970, THERMAL COMFORT
[18]   Simulation of occupancy in buildings [J].
Feng, Xiaohang ;
Yan, Da ;
Hong, Tianzhen .
ENERGY AND BUILDINGS, 2015, 87 :348-359
[19]   Literature survey on how different factors influence human comfort in indoor environments [J].
Frontczak, Monika ;
Wargocki, Pawel .
BUILDING AND ENVIRONMENT, 2011, 46 (04) :922-937
[20]  
Gini C., 1921, The Economic Journal of Nepal, V31, P124, DOI [10.2307/2223319, DOI 10.2307/2223319]