Bone marrow reconversion and magnetic resonance imaging: case report

被引:4
|
作者
Manceron, V
Guignard, S
de Broucker, E
Paycha, F
Pouchot, J
Vinceneux, P
机构
[1] Hop Louis Mourier, Serv Med Interne, F-92701 Colombes, France
[2] Hop Louis Mourier, Serv Radiol, F-92701 Colombes, France
[3] Hop Louis Mourier, Nucl Med Unit, Serv Explorat Fonctionnelles, F-92701 Colombes, France
来源
REVUE DE MEDECINE INTERNE | 2003年 / 24卷 / 12期
关键词
bone marrow reconversion; non Hodgkin's lymphoma; magnetic resonance imaging;
D O I
10.1016/j.revmed.2003.08.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction. Bone marrow is divided into red marrow mainly constituted of hemopoietic cells and fatty yellow marrow. In some situations, yellow marrow may be converted into red marrow and this process is called marrow reconversion. Magnetic resonance imaging may be misleading with an invading bone marrow neoplastic process. Exegesis. We report a patient with non-Hodgkin's lymphoma with vertebral invasion. Clinical features at presentation were misleading with lower limbs migratory pain suggestive of inflammatory myositis. An MRI study of thigh muscles revealed femoral nodular lesions suggestive of bone marrow reconversion. Conclusion. Bone marrow reconversion is a physiologic and reversible process. Awareness of its radiographic features may help to avoid a diagnostic biopsy procedure. (C) 2003 Editions scientifiques et medicales Elsevier SAS. Tous droits reserves.
引用
收藏
页码:830 / 834
页数:5
相关论文
共 50 条
  • [41] Bone marrow magnetic resonance imaging: physiologic and pathologic findings that radiologist should know
    Maria Grazia Chiarilli
    Andrea Delli Pizzi
    Domenico Mastrodicasa
    Maria Pia Febo
    Beatrice Cardinali
    Bruno Consorte
    Antonietta Cifaratti
    Valentina Panara
    Massimo Caulo
    Giovanni Cannataro
    La radiologia medica, 2021, 126 : 264 - 276
  • [42] Acute myelofibrosis: multifocal bone marrow infiltration detected by scintigraphy and magnetic resonance imaging
    Olipitz, W
    Beham-Schmid, C
    Aigner, R
    Raith, J
    Linkesch, W
    Sill, H
    ANNALS OF HEMATOLOGY, 2000, 79 (05) : 275 - 278
  • [43] Magnetic resonance imaging of the bone marrow: Technical aspects - normal findings - anemia - leukemia
    Golder, W
    ONKOLOGIE, 1999, 22 (03): : 200 - 206
  • [44] Bone marrow magnetic resonance imaging of the clivus in pediatric leukemia patients and normal controls
    Tatsuya Nishii
    Atsushi K. Kono
    Yoshinobu Akasaka
    Takeshi Mori
    Akira Hayakawa
    Kazumoto Iijima
    Kazuro Sugimura
    Japanese Journal of Radiology, 2015, 33 : 146 - 152
  • [45] Magnetic Resonance Imaging in Traumatic Brain Injury - a Case Report
    Reguli, S.
    Lipina, R.
    Krajca, J.
    Hanzlikova, P.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2013, 76 (06) : 736 - 739
  • [46] Magnetic Resonance Imaging Findings in Status Epilepticus: A Case Report
    Asfuroglu, Berrak Barutcu
    Urisal, Yaprak OzOm
    Asfuroglu, Umut
    JOURNAL OF EMERGENCY MEDICINE CASE REPORTS, 2021, 12 (02): : 61 - 64
  • [47] Magnetic Resonance Imaging of Nasopharyngeal Adenoid Hypertrophy in Children Following Bone Marrow Transplantation
    Arpaci, Taner
    Karagun, Barbaros S.
    CURRENT MEDICAL IMAGING, 2018, 14 (06) : 1011 - 1016
  • [48] Quantifying Bone Marrow Edema in the Rheumatoid Cervical Spine Using Magnetic Resonance Imaging
    Suppiah, Ravi
    Doyle, Anthony
    Rai, Raylynne
    Dalbeth, Nicola
    Lobo, Maria
    Braun, Juergen
    McQueen, Fiona M.
    JOURNAL OF RHEUMATOLOGY, 2010, 37 (08) : 1626 - 1632
  • [49] Acute myelofibrosis: multifocal bone marrow infiltration detected by scintigraphy and magnetic resonance imaging
    W. Olipitz
    C. Beham-Schmid
    R. Aigner
    J. Raith
    W. Linkesch
    H. Sill
    Annals of Hematology, 2000, 79 : 275 - 278
  • [50] Magnetic resonance imaging study of normal cranial bone marrow conversion at high altitude
    Bao, Haihua
    He, Xin
    Li, Xiaoguang
    Cao, Yuntai
    Zhang, Naihui
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (06) : 3126 - 3137