Renal volume assessment with 3D ultrasound

被引:0
作者
Brancaforte, A. [1 ]
Serantoni, S. [1 ]
Barbosa, F. Silva [1 ]
Di Leo, G. [2 ]
Sardanelli, F. [2 ,3 ]
Cornalba, G. P. [1 ]
机构
[1] Univ Milan, Dipartimento Radiol Diagnost & Interventist, Osped San Paolo, I-20142 Milan, Italy
[2] IRCCS Policlin San Donato, Unita Radiol, Milan, Italy
[3] Univ Milan, Dipartimento Sci Med Chirurg, I-20142 Milan, Italy
来源
RADIOLOGIA MEDICA | 2011年 / 116卷 / 07期
关键词
Ultrasound; 3DMSCT; Renal volume; 665 ADULT VOLUNTEERS; COMPUTED-TOMOGRAPHY; KIDNEY VOLUME; ACCURACY; SIZE; MRI; AGE; CT;
D O I
10.1007/s11547-011-0691-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. This study was undertaken to determine the accuracy of 3D ultrasound (US) in assessing renal volume, with multislice computed tomography (MSCT) considered as the gold standard. Materials and methods. Forty-nine patients (30 men, 19 women; age range 30-82 years) underwent abdominal contrast-enhanced MSCT and 3D-US performed with a 3.5-MHz 3D/4D convex-array probe. The results of the two modalities were compared with the Wilcoxon test. Variability between the two measurements was determined with the Bland-Altman method and reported in terms of bias and coefficient of repeatability (CoR). Results. Mean values obtained were 210 ml with MSCT and 192 ml with 3D-US (p < 0.001). Analysis of variability per patient between MSCT and 3D-US showed a bias of 19 ml, a CoR of 47 ml and an accuracy of 78%, with an average 3D-US underestimation of 19 ml (9%). Analysis of variability per kidney showed a bias of 9 ml, a CoR of 34 ml and an accuracy of 80%. Conclusions. Three-dimensional US is a valuable technique for monitoring renal volume, whereas MSCT may be reserved for assessing renal anatomy and relationships with neighbouring organs.
引用
收藏
页码:1095 / 1104
页数:10
相关论文
共 25 条
[21]   Accuracy of volume measurement using helical CT [J].
Nawaratne, S ;
Fabiny, R ;
Brien, JE ;
Zalcberg, J ;
Cosolo, W ;
Whan, A ;
Morgan, DJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (03) :481-486
[22]   Influence of allograft size to recipient body-weight ratio on the long-term outcome of renal transplantation [J].
Nicholson, ML ;
Windmill, DC ;
Horsburgh, T ;
Harris, KPG .
BRITISH JOURNAL OF SURGERY, 2000, 87 (03) :314-319
[23]   DETERMINATION OF RENAL VOLUME BY ULTRASOUND SCANNING [J].
RASMUSSEN, SN ;
HAASE, L ;
KJELDSEN, H ;
HANCKE, S .
JOURNAL OF CLINICAL ULTRASOUND, 1978, 6 (03) :160-164
[24]   Measurement of Kidney Volume with Multi-Detector Computed Tomography Scanning in Young Korean [J].
Shin, Ho Sik ;
Chung, Byung Ha ;
Lee, Sang Eun ;
Kim, Woo Jin ;
Ha, Hong Il ;
Yang, Chul Woo .
YONSEI MEDICAL JOURNAL, 2009, 50 (02) :262-265
[25]   Quantitative Ultrasound Renal Parenchymal Area Correlates With Renal Volume and Identifies Reflux Nephropathy [J].
Wong, Ilene Yi-Zhen ;
Copp, Hillary Lynne ;
Clark, Curtis J. ;
Wu, Hsi-Yang ;
Shortliffe, Linda Dairiki .
JOURNAL OF UROLOGY, 2009, 182 (04) :1683-1687