Rapid glucose concentration detection utilizing disposable integrated microfluidic chip

被引:34
作者
Hou, Hui-Hsiung [1 ]
Wang, Yao-Nan [2 ]
Chang, Chin-Lung [2 ]
Yang, Ruey-Jen [1 ]
Fu, Lung-Ming [3 ]
机构
[1] Natl Cheng Kung Univ, Dept Engn Sci, Tainan 70101, Taiwan
[2] Natl Pingtung Univ Sci & Technol, Dept Vehicle Engn, Pingtung 912, Taiwan
[3] Natl Pingtung Univ Sci & Technol, Dept Mat Engn, Pingtung 912, Taiwan
关键词
Micromixer; DNS method; CO2 laser machining; Microfluidics; MICROCHIP ELECTROPHORESIS; MIXER; QUANTIFICATION; FABRICATION; MICROMIXER; EFFICIENCY; CYTOMETER; ASSAYS;
D O I
10.1007/s10404-011-0813-6
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A novel three-dimensional (3D) disposable glucose concentration detection chip is presented. The chip comprises a four-layer polymethyl methacrylate (PMMA) structure and is fabricated using a commercial CO2 laser and a hot-press bonding technique. In the proposed device, the glucose solution is injected into a double parallel connection micromixer (DPCM) and is mixed with DNS reagent by means of a self-rotation effect. An experimental platform has been created for multiple reaction process by integrating chip and micro-heater. The fluid streams exiting the two circular mixing chambers of the DPCM are then combined and mixed further at a T-type microchannel outlet before passing to a collection chamber. Numerical simulations are performed to analyze the vortex streamline distribution within the DPCM and to estimate the mixing performance. The numerical results show that a mixing efficiency as high as 92.5% can be obtained at low Reynolds numbers (Re = 12). It is found a good linear relation of R-2 = 0.9953 from the chip detection method comparing to the traditional method of R-2 = 0.9976 at DNS reagent and glucose solution volume ratio of 1:1. In addition, the experimental results show that the accuracy of the glucose concentration measurements obtained using the proposed microfluidic chip is comparable with that of the measurements obtained using a conventional large-scale detection method. Overall, the results presented in this study indicate that the DPCM chip provides a rapid and low-cost means of detecting the concentration of glucose solutions.
引用
收藏
页码:479 / 487
页数:9
相关论文
共 50 条
[1]   AC-electrophoretic deposition of glucose oxidase [J].
Ammam, Malika ;
Fransaer, Jan .
BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) :191-197
[2]   Inertial flow effects in a micro-mixer based on artificial cilia [J].
Baltussen, Michiel ;
Anderson, Patrick ;
Bos, Femke ;
den Toonder, Jaap .
LAB ON A CHIP, 2009, 9 (16) :2326-2331
[3]   Fluid mixing in a T-shaped micro-mixer [J].
Bothe, D ;
Sternich, C ;
Warnecke, HJ .
CHEMICAL ENGINEERING SCIENCE, 2006, 61 (09) :2950-2958
[4]   High-throughput electrokinetic bioparticle focusing based on a travelling-wave dielectrophoretic field [J].
Cheng, I-Fang ;
Chung, Cheng-Che ;
Chang, Hsien-Chang .
MICROFLUIDICS AND NANOFLUIDICS, 2011, 10 (03) :649-660
[5]   Water-assisted CO2 laser ablated glass and modified thermal bonding for capillary-driven bio-fluidic application [J].
Chung, C. K. ;
Chang, H. C. ;
Shih, T. R. ;
Lin, S. L. ;
Hsiao, E. J. ;
Chen, Y. S. ;
Chang, E. C. ;
Chen, C. C. ;
Lin, C. C. .
BIOMEDICAL MICRODEVICES, 2010, 12 (01) :107-114
[6]   Fabrication and flow test of long-term hydrophilic fluidic chip without using any surface modification treatment [J].
Chung, C. K. ;
Chen, Y. S. ;
Shih, T. R. .
MICROFLUIDICS AND NANOFLUIDICS, 2009, 6 (06) :853-857
[7]   Development of an in vitro microassay for glucose quantification in submicrolitre volumes of biological fluid [J].
Ciantar, M ;
Spratt, DA ;
Newman, HN ;
Wilson, M .
JOURNAL OF PERIODONTAL RESEARCH, 2002, 37 (02) :79-85
[8]   Flow optimization study of a batch microfluidics PET tracer synthesizing device [J].
Elizarov, Arkadij M. ;
Meinhart, Carl ;
Miraghaie, Reza ;
van Dam, R. Michael ;
Huang, Jiang ;
Daridon, Antoine ;
Heath, James R. ;
Kolb, Hartmuth C. .
BIOMEDICAL MICRODEVICES, 2011, 13 (01) :231-242
[9]   Microchip electrophoresis in low-temperature co-fired ceramics technology with contactless conductivity measurement [J].
Fercher, Georg ;
Smetana, Walter ;
Vellekoop, Michiel J. .
ELECTROPHORESIS, 2009, 30 (14) :2516-2522
[10]   Electrokinetically driven micro flow cytometers with integrated fiber optics for on-line cell/particle detection [J].
Fu, LM ;
Yang, RJ ;
Lin, CH ;
Pan, YJ ;
Lee, GB .
ANALYTICA CHIMICA ACTA, 2004, 507 (01) :163-169