Blood velocity measurement in healthy and diseased carotid arteries by vector Doppler techniques

被引:0
作者
Lenge, Matteo [1 ,2 ,3 ,4 ,5 ,6 ]
Righi, Daniele [7 ]
Ricci, Stefano [1 ]
Liebgottt, Herve [2 ,3 ,4 ,5 ,6 ]
Tortoli, Piero [1 ]
机构
[1] Univ Florence, Dept Informat Engn, Florence, Italy
[2] Univ Lyon, CREATIS, Villeurbanne, France
[3] CNRS, UMR 5220, Villeurbanne, France
[4] INSERM, U1044, Villeurbanne, France
[5] Univ Lyon 1, F-69622 Villeurbanne, France
[6] INSA Lyon, F-69622 Villeurbanne, France
[7] AOU Careggi, Heart & Vessels Dept, Florence, Italy
来源
2014 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS) | 2014年
关键词
Doppler ultrasound; Vector flow; blood velocity estimation; peak systolic velocity; Real-time; PLANE-WAVES; FLOW; ULTRASOUND;
D O I
10.1109/ULTSYM.2014.0085
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Vector Doppler (VD) methods are increasingly attractive for the capability of providing angle-independent blood velocity measurements. This may be particularly important in carotid artery peak systolic velocity (PSV) measurements, which are widely used for stenosis assessments. Here, two recently introduced VD techniques have been compared to the classic spectral Doppler approach through 37 PSV measurements in common carotid arteries (CCAs) and internal carotid arteries (ICAs) of healthy volunteers and of patients with different degrees of stenosis. The PSVs measured by the two VD techniques were very close to each other for both CCAs and ICAs (0.83 slope coefficient and 7 cm/s intercept value, according to the linear regression analysis). Comparing any of the two VD techniques to the classic method provided a (0.42/0.46) regression coefficient with a (14/20) cm/s intercept value. The high correlation obtained with the two VD techniques supports their suitability to perform accurate PSV measurements in carotid arteries.
引用
收藏
页码:345 / 348
页数:4
相关论文
共 20 条
[1]   Ultrafast Compound Doppler Imaging: Providing Full Blood Flow Characterization [J].
Bercoff, Jeremy ;
Montaldo, Gabriel ;
Loupas, Thanasis ;
Savery, David ;
Meziere, Fabien ;
Fink, Mathias ;
Tanter, Mickael .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (01) :134-147
[2]   Speckle tracking for multi-dimensional flow estimation [J].
Bohs, LN ;
Geiman, BJ ;
Anderson, ME ;
Gebhart, SC ;
Trahey, GE .
ULTRASONICS, 2000, 38 (1-8) :369-375
[3]   A Reconfigurable and Programmable FPGA-Based System for Nonstandard Ultrasound Methods [J].
Boni, Enrico ;
Bassi, Luca ;
Dallai, Alessandro ;
Guidi, Francesco ;
Ramalli, Alessandro ;
Ricci, Stefano ;
Housden, James ;
Tortoli, Piero .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (07) :1378-1385
[4]   Cross-beam vector Doppler ultrasound for angle-independent velocity measurements [J].
Dunmire, B ;
Beach, KW ;
Labs, KH ;
Plett, M ;
Strandness, DE .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (08) :1213-1235
[5]   Simultaneous Quantification of Flow and Tissue Velocities Based on Multi-Angle Plane Wave Imaging [J].
Ekroll, Ingvild Kinn ;
Swillens, Abigail ;
Segers, Patrick ;
Dahl, Torbjorn ;
Torp, Hans ;
Lovstakken, Lasse .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2013, 60 (04) :727-738
[6]  
Evans D.H., 2000, Doppler Ultrasound - physics, instrumentation and clinical applications
[7]   Carotid artery stenosis: Gray-scale and Doppler US diagnosis - Society of Radiologists in Ultrasound consensus conference [J].
Grant, EG ;
Benson, CB ;
Moneta, GL ;
Alexandrov, AV ;
Baker, JD ;
Bluth, EI ;
Carroll, BA ;
Eliasziw, M ;
Gocke, J ;
Hertzberg, BS ;
Katanick, S ;
Needleman, L ;
Pellerito, J ;
Polak, JF ;
Rholl, KS ;
Wooster, DL ;
Zierler, E .
RADIOLOGY, 2003, 229 (02) :340-346
[8]   In vivo comparison of three ultrasound vector velocity techniques to MR phase contrast angiography [J].
Hansen, K. L. ;
Udesen, J. ;
Oddershede, N. ;
Henze, L. ;
Thomsen, C. ;
Jensen, J. A. ;
Nielsen, M. B. .
ULTRASONICS, 2009, 49 (08) :659-667
[9]   A new method for estimation of velocity vectors [J].
Jensen, JA ;
Munk, P .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :837-851
[10]  
Lenge M., 2014, 2014 IEEE INT C AC S, P5162