Stentless Versus Stented Aortic Valve Replacement for Aortic Stenosis

被引:12
作者
Yang, Bo [1 ,2 ]
Makkinejad, Alexander [1 ]
Fukuhara, Shinichi [1 ]
Clemence, Jeffrey [1 ]
Farhat, Linda [1 ]
Malik, Aroosa [1 ]
Wu, Xiaoting [1 ]
Kim, Karen [1 ]
Patel, Himanshu [1 ]
Deeb, Michael [1 ]
机构
[1] Univ Michigan, Dept Cardiac Surg, Michigan Med, Ann Arbor, MI USA
[2] 5155 Frankel Cardiovasc Ctr, 1500 Med Ctr Dr, Ann Arbor, MI 48109 USA
基金
美国国家卫生研究院;
关键词
BIOPROSTHESIS; HEMODYNAMICS; IMPLANTATION; ROOT;
D O I
10.1016/j.athoracsur.2022.01.029
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The differences in long-term outcomes of aortic valve replacement for aortic stenosis between stentless and stented bioprostheses are controversial. METHODS Between 2007 and 2018, 1173 patients underwent aortic valve replacement for aortic stenosis, including 559 treated with a stentless valve and 614 with a stented valve. A propensity score matched cohort with 348 pairs was generated by matching for age, sex, body surface area, bicuspid aortic valve, chronic lung disease, previous cardiac surgery, coronary artery disease, renal failure on dialysis, valve size, concomitant procedures, and surgeon. The primary endpoints of the study were long-term survival and incidence of reoperation. RESULTS Immediate postoperative outcomes were similar between the stentless and stented groups with an overall operative mortality of 2.9% (P = .19). Kaplan-Meier estimation for long-term survival was comparable between the stentless and stented valves in both the whole cohort and the propensity score matched cohort (10-year survival 59% vs 55%, P = .20). The hazard ratio of stentless vs stented valve for risk of long-term mortality was 1.12 (P = .33). The 10 -year cumulative incidence of reoperation due to valve degeneration was 5.5% in the stentless group and 4.7% in the stented group (P = .25). The transvalvular pressure gradient at 5-year follow-up was significantly lower in the stentless group (7 vs 11 mm Hg, P < .001). CONCLUSIONS Both stented and stentless valves could be used in aortic valve replacement for aortic stenosis. We recommend stented valves for aortic valve replacement in patients with aortic stenosis for their simplicity of implantation. (Ann Thorac Surg 2022;114:728-35) (c) 2022 by The Society of Thoracic Surgeons
引用
收藏
页码:728 / +
页数:7
相关论文
共 20 条
[1]   Randomized comparison of exercise haemodynamics of Freestyle, Magna Ease and Trifecta bioprostheses after aortic valve replacement for severe aortic stenosisaEuro [J].
Bach, David S. ;
Patel, Himanshu J. ;
Kolias, Theodore J. ;
Deeb, G. Michael .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (02) :361-367
[2]   Long-term outcomes after transcatheter aortic valve implantation in failed bioprosthetic valves [J].
Bleiziffer, Sabine ;
Simonato, Matheus ;
Webb, John G. ;
Rodes-Cabau, Josep ;
Pibarot, Philippe ;
Kornowski, Ran ;
Windecker, Stephan ;
Erlebach, Magdalena ;
Duncan, Alison ;
Seiffert, Moritz ;
Unbehaun, Axel ;
Frerker, Christian ;
Conzelmann, Lars ;
Wijeysundera, Harindra ;
Kim, Won-Keun ;
Montorfano, Matteo ;
Latib, Azeem ;
Tchetche, Didier ;
Allali, Abdelhakim ;
Abdel-Wahab, Mohamed ;
Orvin, Katia ;
Stortecky, Stefan ;
Nissen, Henrik ;
Holzamer, Andreas ;
Urena, Marina ;
Testa, Luca ;
Agrifoglio, Marco ;
Whisenant, Brian ;
Sathananthan, Janarthanan ;
Napodano, Massimo ;
Landi, Antonio ;
Fiorina, Claudia ;
Zittermann, Armin ;
Veulemans, Verena ;
Sinning, Jan-Malte ;
Saia, Francesco ;
Brecker, Stephen ;
Presbitero, Patrizia ;
De Backer, Ole ;
Sondergaard, Lars ;
Bruschi, Giuseppe ;
Franco, Luis Nombela ;
Petronio, Anna Sonia ;
Barbanti, Marco ;
Cerillo, Alfredo ;
Spargias, Konstantinos ;
Schofer, Joachim ;
Cohen, Mauricio ;
Munoz-Garcia, Antonio ;
Finkelstein, Ariel .
EUROPEAN HEART JOURNAL, 2020, 41 (29) :2731-2742
[3]  
Centers for Disease Control and Prevention National Center for Health Statistics, NAT DEATH IND
[4]   Freedom Solo® versus Trifecta® bioprostheses: clinical and haemodynamic evaluation after propensity score matching [J].
Cerqueira, Rui J. ;
Raimundo, Renata ;
Moreira, Soraia ;
Saraiva, Francisca A. ;
Andrade, Marta ;
Salgueiro, Elson ;
Almeida, Jorge ;
Amorim, Mario Jorge ;
Pinho, Paulo ;
Lourenco, Andre P. ;
Leite-Moreira, Adelino .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (06) :1264-1271
[5]   Stentless Versus Stented Bioprosthetic Aortic Valves A Systematic Review and Meta-Analysis of Controlled Trials [J].
Cheng, Davy ;
Pepper, John ;
Martin, Janet ;
Stanbridge, Rex ;
Ferdinand, Francis D. ;
Jamieson, W. R. Eric ;
Stelzer, Paul ;
Berg, Geoffrey ;
Sani, Guido .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2009, 4 (02) :61-73
[6]   Aortic valve replacement with stentless and stented porcine valves: A case-match study [J].
David, TE ;
Puschmann, R ;
Ivanov, J ;
Bos, J ;
Armstrong, S ;
Feindel, CM ;
Scully, HE .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (02) :236-241
[7]   Stented Versus Stentless Aortic Valve Replacement in Patients With Small Aortic Root A Systematic Review and Meta-Analysis [J].
Harky, Amer ;
Wong, Chris H. M. ;
Hof, Alexander ;
Froghi, Saied ;
Ahmad, Mohammad U. ;
Howard, Callum ;
Rimmer, Lara ;
Bashir, Mohamad .
INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2018, 13 (06) :404-416
[8]   Meta-analysis of valve hemodynamics and left ventricular mass regression for stentless versus stented aortic valves [J].
Kunadian, Babu ;
Vijayalakshmi, Kunadian ;
Thornley, Andrew R. ;
de Belder, Mark A. ;
Hunter, Steven ;
Kendall, Simon ;
Graham, Richard ;
Stewart, Michael ;
Thambyrajah, Jeetendra ;
Dunning, Joel .
ANNALS OF THORACIC SURGERY, 2007, 84 (01) :73-79
[9]   Efficacy of Stentless Aortic Bioprosthesis Implantation for Aortic Stenosis with Small Aortic Annulus [J].
Murashita, Takashi ;
Okada, Yukikatsu ;
Kanemitsu, Hideo ;
Fukunaga, Naoto ;
Konishi, Yasunobu ;
Nakamura, Ken ;
Koyama, Tadaaki .
THORACIC AND CARDIOVASCULAR SURGEON, 2015, 63 (06) :446-451
[10]   Surgical Enlargement of the Aortic Root Does Not Increase the Operative Risk of Aortic Valve Replacement [J].
Rocha, Rodolfo V. ;
Manlhiot, Cedric ;
Feindel, Christopher M. ;
Yau, Terrence M. ;
Mueller, Brigitte ;
David, Tirone E. ;
Ouzounian, Maral .
CIRCULATION, 2018, 137 (15) :1585-+