Influence of shading control patterns on the energy assessment of office spaces

被引:85
作者
da Silva, Pedro Correia [1 ]
Leal, Vitor [1 ]
Andersen, Marilyne [2 ]
机构
[1] Univ Porto, Fac Engn, Dept Mech Engn, P-4200465 Oporto, Portugal
[2] Ecole Polytech Fed Lausanne, Sch Architecture Civil & Environm Engn ENAC, Interdisciplinary Lab Performance Integrated Desi, CH-1015 Lausanne, Switzerland
关键词
Visual comfort; Energy efficiency; Lighting; Glare; Building simulation; Behavioral model; DISCOMFORT GLARE; SIMULATION; SYSTEMS; MODEL;
D O I
10.1016/j.enbuild.2012.03.019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This work reviews existing models of control patterns for occupant-shading interactions in office buildings, and studies their influence in terms of energy demand when comparing transparent facade alternatives. It starts by establishing a review of visual comfort criteria in office buildings and of the conditions that prompt occupants to interact with shading devices and electric lighting. Given the large variety of parameters identified as primary variables in the existing literature - hence the variety of conditions considered comfortable depending on the chosen reference - a sensitivity study was carried out based on dynamic simulations. The aim of the study was to characterize the impact of choosing a given shading control model (pattern or strategy) on the calculated overall energy demand for heating, cooling and lighting, as well as the impact on choosing the best-performing transparent facade option for a single-occupant office. The results show that both the calculated energy performance and the ranking of transparent facade alternatives (glazing and shading) often vary very significantly with control patterns considered for the occupant-shading interaction. They further show that, amongst the eleven control strategies that were considered, the behavioral model based on a glare acceptability threshold (expressed as DGI > 20) is the one that, when considered individually, would most reliably express an average ranking from all considered strategies. The implications of these findings are discussed in view of their applicability to energy performance-based facade design choices evaluation as well as to facade design choices. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:35 / 48
页数:14
相关论文
共 67 条
[1]  
[Anonymous], 2002, 124641 CEN EN
[2]  
[Anonymous], 2009, 11 INT IBPSA C GLASG
[3]  
Bellia L., 2008, VISUAL QUALITY ENERG, VIT
[4]   Adding advanced behavioural models in whole building energy simulation: A study on the total energy impact of manual and automated lighting control [J].
Bourgeois, D ;
Reinhart, C ;
Macdonald, I .
ENERGY AND BUILDINGS, 2006, 38 (07) :814-823
[5]  
Boyce P., 2003, CAPTURING DAYLIGHT D
[6]   Occupant use of switching and dimming controls in offices [J].
Boyce, P. R. ;
Veitch, J. A. ;
Newsham, G. R. ;
Jones, C. C. ;
Heerwagen, J. ;
Myer, M. ;
Hunter, C. M. .
LIGHTING RESEARCH & TECHNOLOGY, 2006, 38 (04) :358-378
[7]   Individual lighting control: Task performance, mood and illuminance [J].
Boyce, PR ;
Eklund, NH ;
Simpson, SN .
JOURNAL OF THE ILLUMINATING ENGINEERING SOCIETY, 2000, 29 (01) :131-+
[8]  
Chartered Institution of Building Services Engineers (CIBSE), 2002, Code for Lighting
[9]  
Cuttle C., 2008, LIGHTING DESIGN
[10]  
Dubois M.-C., 2003, Lighting Research & Technology, V35, P61, DOI 10.1191/1477153503li062oa