Protection against lightning of reinforced concrete buildings

被引:0
|
作者
Bachelier, E. [1 ]
Issac, F. [1 ]
Prost, D. [1 ]
Miry, C. [2 ]
Amador, E. [2 ]
Duquerroy, P. [2 ]
机构
[1] ONERA DEMRCEM, Toulouse, France
[2] EDF R&D LME, Moret Sur Loing, France
关键词
Full-wave numerical methods; computational electromagnetic; lightning; shielding effectiveness;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a methodology to determine the shielding effectiveness of a reinforced concrete building struck by lightning using experimental and numerical analysis. Validated numerical model of the building is then used to compute expected magnetic fields in case of realistic lightning strike.
引用
收藏
页码:735 / 740
页数:6
相关论文
共 50 条
  • [1] Protection against lightning and overvoltage in buildings with a large electronics
    Rous, Zdenek
    Kutac, Jiri
    PROCEEDINGS OF THE 5TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2003, 2003, : 552 - 569
  • [2] LIGHTNING PROTECTION OF BUILDINGS
    LEE, RH
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1979, 15 (03) : 236 - 240
  • [3] LIGHTNING PROTECTION FOR BUILDINGS
    HEDLUND, CF
    IEEE TRANSACTIONS ON INDUSTRY AND GENERAL APPLICATIONS, 1967, IGA3 (01): : 26 - &
  • [4] Evaluation of Lightning Induced Magnetic Fields Inside Reinforced Concrete Buildings
    Miry, C.
    Amador, E.
    Duquerroy, P.
    Bachelier, E.
    Prost, D.
    Issac, F.
    2013 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XII SIPDA), 2013, : 145 - 150
  • [5] Physical Principles Guiding the Protection of Buildings Against Lightning.
    Gary, Claude
    Revue generale de l'electricite Paris, 1980, 89 (05): : 351 - 367
  • [6] Some observations on the protection of buildings against the induced effects of lightning
    Montandon, Eric
    Rubinstein, Marcos
    IEEE Transactions on Electromagnetic Compatibility, 1998, 40 (4 pt 2): : 505 - 512
  • [7] Some observations on the protection of buildings against the induced effects of lightning
    Montandon, E
    Rubinstein, M
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1998, 40 (04) : 505 - 512
  • [8] REPAIR AND PROTECTION OF REINFORCED CONCRETE IN HIGH RISE BUILDINGS.
    Ovens, A.
    Concrete (London), 1984, 18 (05): : 21 - 22
  • [9] Investigation of lightning surge current induced in reinforced concrete buildings by direct strikes
    Kato, J
    Kawano, H
    Tominaga, T
    Kuramoto, S
    2001 IEEE EMC INTERNATIONAL SYMPOSIUM, VOLS 1 AND 2, 2001, : 1009 - 1014
  • [10] Evaluating protection against lightning for historical buildings and cultural heritage monuments
    Ioannidis, Alexios I.
    Mikropoulos, Pantelis N.
    Tsovilis, Thomas E.
    Kokkinos, Nikolaos D.
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 230