A rapid method for determination of L-lactic acid in real samples by amperometric biosensor utilizing nanocomposite

被引:48
|
作者
Monosik, Rastislav [1 ]
Stredansky, Miroslav [2 ]
Greif, Gabriel
Sturdik, Ernest [1 ]
机构
[1] Slovak Univ Technol Bratislava, Inst Biochem Nutr & Hlth Protect, Fac Chem & Food Technol, Bratislava 81237, Slovakia
[2] Biorealis SRO, Bratislava 84104, Slovakia
关键词
L-lactic acid; Biosensor; Analysis; Real samples; Nanotubes; L-LACTATE; CARBON NANOTUBES; ELECTROCHEMICAL BIOSENSORS; CHITOSAN; OXIDASE; ELECTRODES; COMPOSITE; MATRIX; SYSTEM; FILM;
D O I
10.1016/j.foodcont.2011.07.021
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Amperometric biosensors based on gold planar electrode and on two types of nanocomposite electrodes consisting of multi-walled carbon nanotubes for determination of L-lactic acid designed for wine-makers were developed and used for an analysis of real food samples and beverages. The biosensors were constructed by immobilization of L-lactate oxidase and peroxidase within chitosan layers on the surface of the electrodes. As a mediator, ferrocyanide was used. The current resulted from re-oxidation of produced ferricyanide was measured at working potential of -50 mV against Ag/AgCl reference electrode. The biosensor based on gold electrode showed linearity over the range 5-244 mu M with the detection limit of 0.96 mu M. Calibration curves for biosensors utilizing two types of nanocomposites consisting of N-eikosane and multi-waled carbon nanotubes (d = 60-100 nm, L = 5-15 mu m, 95+% purity or d = 9.5 nm, L = 1.5 mu m, 90+% purity) were obtained both with the linear range of 5-340 mu M. The detection limits were 1.62 and 1.66 mu M, respectively. All types of biosensors had response time of 65s. The biosensors showed satisfactory operational stability (no loss of sensitivity after 60 consecutive measurements) and an excellent storage stability (90% of the initial sensitivity after 15 months of storage at room temperature). Finally the results obtained from measurements of food and wine samples were compared with those obtained with an enzymatic-spectrophotometric and standard HPLC method. The biosensors based on 3 different configurations were able to determine low concentration (0.02 -0.12 g L-1) of lactic acid level, what was not possible by reference analytical methods and a comparison between results obtained by the biosensors and reference methods agreed very well at concentration of lactic acid above 1.4 g L-1. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] Determination of l-lactic acid in yoghurt by a bienzyme amperometric graphite–Teflon composite biosensor
    A. M. Herrero
    T. Requena
    A. J. Reviejo
    J. M. Pingarrón
    European Food Research and Technology, 2004, 219 : 557 - 560
  • [2] Determination of L-lactic acid in yoghurt by a bienzyme amperometric graphite-Teflon composite biosensor
    Herrero, AM
    Requena, T
    Reviejo, AJ
    Pingarrón, JM
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2004, 219 (05) : 556 - 559
  • [3] METHOD FOR DETERMINATION OF L-LACTIC ACID
    KITAHARA, K
    HIYAMA, T
    TAI, A
    MIZUSHIMA, S
    JOURNAL OF GENERAL AND APPLIED MICROBIOLOGY, 1964, 10 (01): : 45 - +
  • [4] Zinc oxide nanowires-based electrochemical biosensor for L-lactic acid amperometric detection
    Yanguang Zhao
    Xiaoqin Yan
    Zhuo Kang
    Xiaofei Fang
    Xin Zheng
    Lanqing Zhao
    Hongwu Du
    Yue Zhang
    Journal of Nanoparticle Research, 2014, 16
  • [5] Zinc oxide nanowires-based electrochemical biosensor for L-lactic acid amperometric detection
    Zhao, Yanguang
    Yan, Xiaoqin
    Kang, Zhuo
    Fang, Xiaofei
    Zheng, Xin
    Zhao, Lanqing
    Du, Hongwu
    Zhang, Yue
    JOURNAL OF NANOPARTICLE RESEARCH, 2014, 16 (05)
  • [6] Determination of L-Lactic Acid Content in Foods by Enzyme-Based Amperometric Bioreactor
    Bori, Zsuzsanna
    Csiffary, Gabor
    Virag, Diana
    Toth-Markus, Marianna
    Kiss, Attila
    Adanyi, Nora
    ELECTROANALYSIS, 2012, 24 (01) : 158 - 164
  • [7] Wireless Biosensor System for Real-Time L-Lactic Acid Monitoring in Fish
    Hibi, Kyoko
    Hatanaka, Kengo
    Takase, Mai
    Ren, Huifeng
    Endo, Hideaki
    SENSORS, 2012, 12 (05): : 6269 - 6281
  • [8] An Amperometric Biosensor for the Determination of Lactic Acid During Malolactic Fermentation
    Sannini, Adriana
    Albanese, Donatella
    Malvano, Francesca
    Crescitelli, Alessio
    Di Matteo, Marisa
    FRUTIC ITALY 2015: 9TH NUT AND VEGETABLE PRODUCTION ENGINEERING SYMPOSIUM, 2015, 44 : 283 - 288
  • [9] AMPEROMETRIC DETERMINATION OF LACTIC-ACID - APPLICATIONS ON MILK SAMPLES
    PILLOTON, R
    NWOSU, TN
    MASCINI, M
    ANALYTICAL LETTERS, 1988, 21 (05) : 727 - 740
  • [10] L-Lactic acid biosensor based on multi-layered graphene
    Radoi, Antonio
    Obreja, Alexandru Cosmin
    Eremia, Sandra A. V.
    Bragaru, Adina
    Dinescu, Adrian
    Radu, Gabriel-Lucian
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2013, 43 (10) : 985 - 994