Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging

被引:32
作者
Torfeh, Tarraf [1 ]
Hammoud, Rabih [1 ]
McGarry, Maeve [1 ]
Al-Hammadi, Noora [1 ]
Perkins, Gregory [1 ]
机构
[1] Hamad Med Corp, Natl Ctr Canc Care & Res, Dept Radiat Oncol, Doha, Qatar
关键词
Quality control; Magnetic resonance imaging; Geometric distortion; Software tools; CLINICAL MRI SYSTEMS; SCHEME;
D O I
10.1016/j.mri.2015.04.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. Materials and Methods: A purpose built phantom was developed consisting of 357 rods (6 mm in diameter) of polymethyl-methacrylat separated by 20 mm intervals, providing a three dimensional array of control points at known spatial locations covering a large field of view up to a diameter of 420 mm. An in-house software module was developed to allow automatic geometric distortion assessment. This software module was validated against a virtual dataset of the phantom that reproduced the exact geometry of the physical phantom, but with known translational and rotational displacements and warping. For validation experiments, clinical MRI sequences were acquired with and without the application of a commercial 3D distortion correction algorithm (Gradwarp (TM)). The software module was used to characterize and assess system-related geometric distortion in the sequences relative to a benchmark a dataset, and the efficacy of the vendor geometric distortion correction algorithms (GDC) was also assessed. Results: Results issued from the validation of the software against virtual images demonstrate the algorithm's ability to accurately calculate geometric distortion with sub-pixel precision by the extraction of rods and quantization of displacements. Geometric distortion was assessed for the typical sequences used in radiotherapy applications and over a clinically relevant 420 mm field of view (FOV). As expected and towards the edges of the field of view (FOV), distortion increased with increasing FOV. For all assessed sequences, the vendor GDC was able to reduce the mean distortion to below 1 mm over a field of view of 5, 10, 15 and 20 cm radius respectively. Conclusion: Results issued from the application of the developed phantoms and algorithms demonstrate a high level of precision. The results indicate that this platform represents an important, robust and objective tool to perform routine quality assurance of MR-guided therapeutic applications, where spatial accuracy is paramount. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:939 / 949
页数:11
相关论文
共 19 条
  • [11] A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom
    Wang, DM
    Doddrell, DM
    MEDICAL PHYSICS, 2004, 31 (08) : 2212 - 2218
  • [12] Quality assurance of magnetic resonance imaging for a polymer gel dosimeter using a 3D-printed phantom
    Tachibana, Hidenobu
    Hoshino, Yoshihiko
    Watanabe, Yusuke
    Usui, Keisuke
    Mizukami, Shinya
    Shibukawa, Shuhei
    Kodama, Takashi
    Tachibana, Rie
    RADIATION PHYSICS AND CHEMISTRY, 2025, 226
  • [13] Development of a standard phantom for diffusion-weighted magnetic resonance imaging quality control studies: A review
    Manson, Eric Naab
    Mumuni, Abdul Nashirudeen
    Shirazu, Issahaku
    Hasford, Francis
    Inkoom, Stephen
    Sosu, Edem
    Aikins, Mark Pokoo
    Mohammed, Gedel Ahmed
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (04): : 169 - 179
  • [14] Value of dedicated small-field-of-view sacroiliac versus large-field-of-view pelvic magnetic resonance imaging for evaluating pediatric sacroiliitis
    Sagar Wagle
    Jeff T. Gu
    Jesse L. Courtier
    Andrew S. Phelps
    Clara Lin
    John D. MacKenzie
    Pediatric Radiology, 2019, 49 : 933 - 940
  • [15] Value of dedicated small-field-of-view sacroiliac versus large-field-of-view pelvic magnetic resonance imaging for evaluating pediatric sacroiliitis
    Wagle, Sagar
    Gu, Jeff T.
    Courtier, Jesse L.
    Phelps, Andrew S.
    Lin, Clara
    MacKenzie, John D.
    PEDIATRIC RADIOLOGY, 2019, 49 (07) : 933 - 940
  • [16] Development and Preliminary Validation of a Digital Overlay-based Learning Module for Semiquantitative Evaluation of Magnetic Resonance Imaging Lesions in Osteoarthritis of the Hip
    Maksymowych, Walter P.
    Pitts, Meaghan
    Budak, Matthew J.
    Gracey, David
    Lambert, Robert G.
    McDougall, David
    Pianta, Marcus
    Rennie, Winston J.
    Wichuk, Stephanie
    Winn, Naomi
    Jaremko, Jacob L.
    JOURNAL OF RHEUMATOLOGY, 2016, 43 (01) : 232 - 238
  • [17] Deep learning-based magnetic resonance imaging reconstruction for improving the image quality of reduced-field-of-view diffusion-weighted imaging of the pancreas
    Takayama, Yukihisa
    Sato, Keisuke
    Tanaka, Shinji
    Murayama, Ryo
    Goto, Nahoko
    Yoshimitsu, Kengo
    WORLD JOURNAL OF RADIOLOGY, 2023, 15 (12):
  • [18] Development of Image Overlay and Knowledge Transfer Module Technologies Aimed at Enhancing Feasibility and External Validation of Magnetic Resonance Imaging-based Scoring Systems
    Jaremko, Jacob L.
    Pitts, Meaghan
    Maksymowych, Walter P.
    Lambert, Robert G.
    JOURNAL OF RHEUMATOLOGY, 2016, 43 (01) : 223 - 231
  • [19] Development and External Validation of a Novel Nomogram to Predict the Probability of Pelvic Lymph-node Metastases in Prostate Cancer Patients Using Magnetic Resonance Imaging and Molecular Imaging with Prostate-specific Membrane Antigen Positron Emission Tomography
    Vis, Andre N.
    Meijer, Dennie
    Roberts, Matthew J.
    Siriwardana, Amila R.
    Morton, Andrew
    Yaxley, John W.
    Samaratunga, Hemamali
    Emmett, Louise
    van de Ven, Peter M.
    Heymans, Martijn W.
    Nieuwenhuijzen, Jakko A.
    van der Poel, Henk G.
    Donswijk, Maarten L.
    Boellaard, Thierry N.
    Schoots, Ivo G.
    Stricker, Phillip
    Haynes, Anne-Maree
    Oprea-Lager, Daniela E.
    Coughlin, Geoffrey D.
    van Leeuwen, Pim J.
    EUROPEAN UROLOGY ONCOLOGY, 2023, 6 (06): : 553 - 563