Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion Pooled Data From 2 Multisite Randomized Controlled Trials

被引:8
|
作者
Leung, Felix W. [1 ,2 ]
Koo, Malcolm [5 ,9 ]
Cadoni, Sergio [10 ]
Falt, Premysl [13 ]
Hsieh, Yu-Hsi [6 ,7 ]
Amato, Arnaldo [11 ]
Erriu, Matteo [12 ]
Fojtik, Petr [13 ]
Gallittu, Paolo [10 ]
Hu, Chi-Tan [7 ,8 ]
Leung, Joseph W. [3 ,4 ]
Liggi, Mauro [10 ]
Paggi, Silvia [11 ]
Radaelli, Franco [11 ]
Rondonotti, Emanuele [11 ]
Smajstrla, Vit [13 ]
Tseng, Chih-Wei [6 ,7 ]
Urban, Ondrej [13 ]
机构
[1] Vet Affairs Los Greater Angeles Healthcare Syst, Dept Gastroenterol Med, Sepulveda Ambulatory Care Ctr, North Hill, CA 91343 USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Dept Gastroenterol Med, Los Angeles, CA 90095 USA
[3] Univ Calif Davis, Med Ctr, Dept Gastroenterol, Sacramento, CA USA
[4] Vet Affairs Northern Calif Healthcare Syst, Dept Gastroenterol, Sacramento VAMC, Mather, CA USA
[5] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Med Res, Chiayi, Taiwan
[6] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Gastroenterol Med, Chiayi, Taiwan
[7] Tzu Chi Univ, Sch Med, Gastroenterol Med, Hualien, Taiwan
[8] Hualien Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Dept Gastroenterol, Hualien, Taiwan
[9] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[10] St Barbara Hosp, Digest Endoscopy Unit, Iglesias, CI, Italy
[11] Valduce Hosp, Dept Digest Endoscopy & Gastroenterol, Como, Italy
[12] Univ Cagliari CA, Dept Surg Sci, Cagliari, CA, Italy
[13] Vitkovice Hosp, Ctr Digest Dis, Ostrava, Czech Republic
关键词
adenoma detection rate (ADR); air insufflation (AI); water immersion (WI); water exchange (WE); AIR INSUFFLATION; QUALITY INDICATOR; COLORECTAL-CANCER; COLONOSCOPY; INFUSION; MULTICENTER; INTUBATION; SEDATION; RISK;
D O I
10.1097/MCG.0000000000001012
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Goals: To test the hypothesis that water exchange (WE) significantly increases adenoma detection rates (ADR) compared with water immersion (WI). Background: Low ADR was linked to increased risk for interval colorectal cancers and related deaths. Two recent randomized controlled trials of head-to-head comparison of WE, WI, and traditional air insufflation (AI) each showed that WE achieved significantly higher ADR than AI, but not WI. The data were pooled from these 2 studies to test the above hypothesis. Study: Two trials (5 sites, 14 colonoscopists) that randomized 1875 patients 1:1:1 to AI, WI, or WE were pooled and analyzed with ADR as the primary outcome. Results: The ADR of AI (39.5%) and WI (42.4%) were comparable, significantly lower than that of WE (49.6%) (vs. AI P=0.001; vs. WI P=0.033). WE insertion time was 3 minutes longer than that of AI (P<0.001). WE showed significantly higher detection rate (vs. AI) of the >10 mm advanced adenomas. Right colon combined advanced and sessile serrated ADR of AI (3.4%) and WI (5%) were comparable and were significantly lower than that of WE (8.5%) (vs. AI PP=0.039). Conclusions: Compared with AI and WI, the superior ADR of WE offsets the drawback of a significantly longer insertion time. For quality improvement focused on increasing adenoma detection, WE is preferred over WI. The hypothesis that WE could lower the risk of interval colorectal cancers and related deaths should be tested.
引用
收藏
页码:204 / 209
页数:6
相关论文
共 13 条
  • [1] Water Exchange Method Significantly Improves Adenoma Detection Rate: A Multicenter, Randomized Controlled Trial
    Jia, Hui
    Pan, Yanglin
    Guo, Xuegang
    Zhao, Lina
    Wang, Xiangping
    Zhang, Linhui
    Dong, Tao
    Luo, Hui
    Ge, Zhizheng
    Liu, Jun
    Hao, Jianyu
    Yao, Ping
    Zhang, Yao
    Ren, Hongyu
    Zhou, Weizhen
    Guo, Yujie
    Zhang, Wei
    Chen, Xiaolin
    Sun, Dayong
    Yang, Xiaoqiang
    Kang, Xiaoyu
    Liu, Na
    Liu, Zhiguo
    Leung, Felix
    Wu, Kaichun
    Fan, Daiming
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 (04) : 568 - 576
  • [2] Adenoma and Advanced Adenoma Detection Rates of Water Exchange, Endocuff, and Cap Colonoscopy: A Network Meta-Analysis with Pooled Data of Randomized Controlled Trials
    Shao, Paul P.
    Bui, Aileen
    Romero, Tahmineh
    Jia, Hui
    Leung, Felix W.
    DIGESTIVE DISEASES AND SCIENCES, 2021, 66 (04) : 1175 - 1188
  • [3] Water Exchange (WE) and Quality Improvement-Enhanced Advanced Adenoma Detection A Pooled Data Analysis of 6 Randomized Controlled Trials
    Leung, Felix W.
    Koo, Malcolm
    Jia, Hui
    Leung, Joseph W.
    Cadoni, Sergio
    Falt, Premysl
    Hsieh, Yu-Hsi
    Hu, Chi-Tan
    Pan, Yanglin
    Radaelli, Franco
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2020, 54 (03) : 212 - 217
  • [4] Prospective multicenter randomized controlled trial comparing adenoma detection rate in colonoscopy using water exchange, water immersion, and air insufflation
    Hsieh, Yu-Hsi
    Tseng, Chih-Wei
    Hu, Chi-Tan
    Koo, Malcolm
    Leung, Felix W.
    GASTROINTESTINAL ENDOSCOPY, 2017, 86 (01) : 192 - 201
  • [5] Comparison of Right Colon Flat Polyp Detection Rate by Water Exchange Versus Water Immersion-pooled Results of Data File of 3 Published Reports
    Leung, Felix W.
    Koo, Malcolm
    Jia, Hui
    Cadoni, Sergio
    Hsieh, Yu-Hsi
    Leung, Joseph W.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2024, 58 (02) : 156 - 161
  • [6] Water exchange colonoscopy increases adenoma detection rate: a systematic review with network meta-analysis of randomized controlled studies
    Fuccio, Lorenzo
    Frazzoni, Leonardo
    Hassan, Cesare
    La Marca, Marina
    Paci, Valentina
    Smania, Veronica
    De Bortoli, Nicola
    Bazzoli, Franco
    Repici, Alessandro
    Rex, Douglas
    Cadoni, Sergio
    GASTROINTESTINAL ENDOSCOPY, 2018, 88 (04) : 589 - +
  • [7] Comparing right colon adenoma detection rate during water exchange and air insufflation: a double-blind randomized controlled trial
    Tseng, C-W
    Hsieh, Y-H
    Koo, M.
    Leung, F. W.
    TECHNIQUES IN COLOPROCTOLOGY, 2022, 26 (01) : 35 - 44
  • [8] How to increase proximal adenoma detection rate: a meta-analysis comparing water exchange, water immersion and air/CO2 insufflation methods for colonoscopy
    Aziz, Muhammad
    Sharma, Sachit
    Fatima, Rawish
    Lee-Smith, Wade
    Sodeman, Thomas
    Nawras, Ali
    Adler, Douglas G.
    ANNALS OF GASTROENTEROLOGY, 2020, 33 (02): : 178 - +
  • [9] Water exchange for screening colonoscopy increases adenoma detection rate: a multicenter, double-blinded, randomized controlled trial
    Cadoni, Sergio
    Falt, Premysl
    Rondonotti, Emanuele
    Radaelli, Franco
    Fojtik, Petr
    Gallittu, Paolo
    Liggi, Mauro
    Amato, Arnaldo
    Paggi, Silvia
    Smajstrla, Vit
    Urban, Ondrej
    Erriu, Matteo
    Koo, Malcolm
    Leung, Felix W.
    ENDOSCOPY, 2017, 49 (05) : 456 - 467
  • [10] Comparing right colon adenoma detection rate during water exchange and air insufflation: a double-blind randomized controlled trial
    C.- W. Tseng
    Y.- H. Hsieh
    M. Koo
    F. W. Leung
    Techniques in Coloproctology, 2022, 26 : 35 - 44