Experimental and Monte Carlo analyses of a-Se and CsI:Na/a-Se for X-ray imaging

被引:0
|
作者
Choi, JY [1 ]
Park, JK [1 ]
Kang, SS [1 ]
Kim, JY [1 ]
Lee, KH [1 ]
Im, JG [1 ]
Nam, SH [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Radiat Image Lab, Kimhae, South Korea
来源
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7 | 2004年
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the pertinence of a solution using thin coplanar selenium as a photosensitive converter requiting only a few tens of volts of bias, associated with a thick columnar coating of sodium-doped cesium iodide scintillator, was evaluated. A new evaporation process for direct CsI:Na deposition on an a-Se layer substrate was developed. The photoluminescence characterization of this scintillator shows a light emission peak centered at 420 nm, as expected, which matches the sensitivity spectrum of selenium. In addition, to optimize the thickness of the CsI:Na/a-Se structure, the X-ray absorption was investigated at various diagnostic X-ray energy levels using the MCNP 4C code. The Monte Carlo simulation results showed that the absorption fraction of 500 mu m-Se film and 180 mu m-CsI(Na) film is about 80% at 60 kVp. The simulation results were verified by comparing these with experimental measurements and results. The measured dark currents were below 300 pA/cm(2) at an electric field of 10 V/mu m for a-Se and CsI:Na/a-Se. The preliminary sensitivity measurements give a signal in the range of about 7.31 and 3.95 nC/cm(2)/mR for 180 mu m-CsI:Tl/a-Se and 500 mu m-Se at the exposure conditions of 60 kVp and 2-mm aluminum filter, respectively.
引用
收藏
页码:4501 / 4505
页数:5
相关论文
共 50 条
  • [31] Tellurium doped a-Se devices for improved optical absorption in indirect X-ray photodetection
    Hellier, Kaitlin
    Benard, Emmie
    Abbaszadeh, Shiva
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [32] Monte Carlo detective quantum efficiency and scatter studies of a metal/a-Se portal detector
    McGill University, Medical Physics Unit, Montreal General Hospital, 1650 Cedar Ave., Montreal, Que. H3G 1A4, Canada
    Med. Phys., 7 I (1186-1194):
  • [33] Monte Carlo detective quantum efficiency and scatter studies of a metal/a-Se portal detector
    Lachaine, M
    Fallone, BG
    MEDICAL PHYSICS, 1998, 25 (07) : 1186 - 1194
  • [34] a-Se薄膜在X-ray照射下的光衰特性研究
    郭震
    张观明
    武汉大学学报(理学版), 2002, (05) : 597 - 600
  • [35] INFLUENCE OF BISMUTH DOPING ON THE X-RAY-INDUCED CONDUCTIVITY OF A-SE LAYERS
    WITTE, H
    HERMS, W
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1992, 132 (02): : K71 - K73
  • [36] Effects of x-ray irradiation on charge transport and charge collection efficiency in stabilized a-Se photoconductors
    Kasap, S. O.
    Yang, J.
    Simonson, B.
    Adeagbo, E.
    Walornyj, M.
    Belev, G.
    Bradley, M. P.
    Johanson, R. E.
    JOURNAL OF APPLIED PHYSICS, 2020, 127 (08)
  • [37] Experimental study of the density of states in the band gap of a-Se
    Benkhedir, ML
    Aida, MS
    Qamhieh, N
    Stesmans, A
    Adriaenssens, GJ
    JOURNAL OF OPTOELECTRONICS AND ADVANCED MATERIALS, 2005, 7 (01): : 329 - 332
  • [38] Columnar recombination for X-ray generated electron-holes in amorphous selenium and its significance in a-Se x-ray detectors
    Bubon, O.
    Jandieri, K.
    Baranovskii, S. D.
    Kasap, S. O.
    Reznik, A.
    JOURNAL OF APPLIED PHYSICS, 2016, 119 (12)
  • [39] X-Ray Detection Using a Two-Transistor Active Pixel Sensor Array Coupled to an a-Se X-Ray Photoconductor
    Taghibakhsh, Farhad
    Karim, Karim S.
    Belev, George
    Kasap, Safa O.
    IEEE SENSORS JOURNAL, 2009, 9 (1-2) : 51 - 56
  • [40] Charge transport and electron-hole-pair creation energy in stabilized a-Se x-ray photoconductors
    Haugen, C.
    Kasap, S.O.
    Rowlands, J.
    Journal of Physics D: Applied Physics, 32 (03): : 200 - 207