Organic compounds in indoor air - their relevance for perceived indoor air quality?

被引:303
作者
Wolkoff, P [1 ]
Nielsen, GD [1 ]
机构
[1] Natl Inst Occupat Hlth, DK-2100 Copenhagen O, Denmark
关键词
airway irritation; indoor air quality; OCIA; odour annoyance; TVOC; volatile organic compounds (VOCs);
D O I
10.1016/S1352-2310(01)00244-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
It is generally believed that indoor air pollution, one way or another may cause indoor air complaints. However, any association between volatile organic compounds (VOCs) concentrations and increase of indoor climate complaints, like the sick-building syndrome symptoms, is not straightforward. The reported symptom rates of, in particular, eye and upper airway irritation cannot generally be explained by our present knowledge of common chemically non-reactive VOCs measured indoors. Recently, experimental evidence has shown those chemical reactions between ozone (either with or without nitrogen dioxide) and unsaturated organic compounds (e.g. from citrus and pine oils) produce strong eye and airway irritating species. These have not yet been well characterised by conventional sampling and analytical techniques. The chemical reactions can occur indoors, and there is indirect evidence that they are associated with eye and airway irritation. However, many other volatile and non-volatile organic compounds have not generally been measured which could equally well have potent biological effects and cause an increase of complaint rates, and posses a health/comfort risk. As a consequence, it is recommended to use a broader analytical window of organic compounds than the classic VOC window as defined by the World Health Organisation. It may include hitherto not yet sampled or identified intermediary species (e.g., radicals, hydroperoxides and ionic compounds like detergents) as well as species deposited onto particles. Additionally, sampling strategies including emission testing of building products should carefully be linked to the measurement of organic compounds that are expected, based on the best available toxicological knowledge, to have biological effects at indoor concentrations. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:4407 / 4417
页数:11
相关论文
共 50 条
  • [1] Built environment and indoor air quality: The case of volatile organic compounds
    Kotzias, Dimitrios
    AIMS ENVIRONMENTAL SCIENCE, 2021, 8 (02) : 135 - 147
  • [2] Total volatile organic compounds (TVOC) in indoor air quality investigations
    Molhave, L
    Clausen, G
    Berglund, B
    de Ceaurriz, J
    Kettrup, A
    Lindvall, T
    Maroni, M
    Pickering, AC
    Risse, U
    Rothweiler, H
    Seifert, B
    Younes, M
    INDOOR AIR, 1997, 7 (04) : 225 - 240
  • [3] Intermediate volatile organic compounds in Canadian residential air in winter: Implication to indoor air quality
    Feng, Yong -Lai
    Yang, Chun
    Cao, Xu-Liang
    CHEMOSPHERE, 2023, 328
  • [4] Effects of Volatile Organic Compounds Released by Different Decorative Particleboards on Indoor Air Quality
    Jiang, Liqun
    Shen, Jun
    Li, Hongwei
    Wang, Qifan
    Shen, Xiwei
    BIORESOURCES, 2018, 13 (04): : 7595 - 7605
  • [5] The effect of perceived indoor air quality on productivity loss
    Kosonen, R
    Tan, F
    ENERGY AND BUILDINGS, 2004, 36 (10) : 981 - 986
  • [6] Psychosocial Problems, Indoor Air-Related Symptoms, and Perceived Indoor Air Quality among Students in Schools without Indoor Air Problems: A Longitudinal Study
    Finell, Eerika
    Tolvanen, Asko
    Pekkanen, Juha
    Minkkinen, Jaana
    Stahl, Timo
    Rimpela, Arja
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (07)
  • [8] The biofiltration of indoor air: Implications for air quality
    Darlington, A
    Chan, M
    Malloch, D
    Pilger, C
    Dixon, MA
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 2000, 10 (01): : 39 - 46
  • [9] MODELING OF INDOOR AIR QUALITY
    Teodosiu, Catalin
    Ilie, Viorel
    Teodosiu, Raluca
    ENERGY AND CLEAN TECHNOLOGIES, 2015, : 969 - 976
  • [10] Indoor Air Quality in offices
    Martin Zorraquino, Juan Vicente
    Mendivil Martinez, Ainhoa
    DYNA, 2008, 83 (05): : 296 - 304