Design and characterization of Kenics static mixer crystallizers

被引:22
|
作者
Thomas, Kiran Mathew [1 ]
Nyande, Baggie W. [1 ]
Lakerveld, Richard [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Dept Chem & Biol Engn, Clear Water Bay, Hong Kong, Peoples R China
来源
CHEMICAL ENGINEERING RESEARCH & DESIGN | 2022年 / 179卷
关键词
Crystallization; Static mixer; Continuous crystallization; CFD; Lysozyme; 3D printing; FLOW TUBULAR CRYSTALLIZATION; RESIDENCE TIME DISTRIBUTION; NATURAL COOLING MODE; PRESSURE-DRIVEN FLOW; PARTICLE MIGRATION; PROTEIN CRYSTALLIZATION; PROCESS INTENSIFICATION; BATCH CRYSTALLIZATION; SECONDARY NUCLEATION; POLYMORPH SELECTION;
D O I
10.1016/j.cherd.2022.01.025
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Tubular crystallizers are desirable for continuous operations because they can approach plug flow conditions, achieve higher throughputs, and can be easy to control. However, the possible limitations of tubular crystallizers may include settling of crystals, fouling and higher pressure drops at longer residence times. The performance of a tubular crystallizer with gaps between the Kenics type mixing elements is characterized and compared with a standard Kenics static mixer and a hollow tubular crystallizer for the crystallization of lysozyme from solution. The gapped Kenics static mixer crystallizer provides an attractive trade-off between the standard Kenics static mixer and the hollow tubular crystallizer in terms of mixing length, shear rate, residence time distribution, pressure drop and segregation or settling of crystals. Furthermore, the gapped Kenics static mixer crystallizer and the standard Kenics static mixer crystallizer exhibit a similar crystallization performance in terms of desupersaturation profile and mean crystal size at the outlet for different initial lysozyme concentrations and seed loadings. The advantages of the gapped Kenics static mixer crystallizer in terms of pressure drop and minimization of crystal settling allow for lower flow rates and longer residence times under plug flow conditions, which has important practical benefits for continuous crystallization. (c) 2022 Published by Elsevier Ltd on behalf of Institution of Chemical Engineers.
引用
收藏
页码:549 / 563
页数:15
相关论文
共 50 条
  • [41] COMPUTATIONAL FLUID DYNAMICS AND EXPERIMENTAL STUDIES OF A NEW MIXING ELEMENT IN A STATIC MIXER AS A HEAT EXCHANGER
    Konopacki, Maciej
    Kordas, Marian
    Fijalkowski, Karol
    Rakoczy, Rafal
    CHEMICAL AND PROCESS ENGINEERING-INZYNIERIA CHEMICZNA I PROCESOWA, 2015, 36 (01): : 59 - 72
  • [42] Numerical study of the heat transfer rate in a helical static mixer
    Rahmani, Ramin K.
    Keith, Theo G.
    Ayasoufi, Anahita
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2006, 128 (08): : 769 - 783
  • [43] INFLUENCE OF STATIC MIXER ON THE FORMATION OF BIOGRANULES
    Sulaiman, Suryati
    Aris, Azmi
    Abd Razak, Abdul Syukor
    Muda, Khalida
    Anuar, Aznah Nor
    JURNAL TEKNOLOGI-SCIENCES & ENGINEERING, 2019, 81 (01): : 23 - 30
  • [44] Understanding and Optimizing the SMX Static Mixer
    Singh, Mrityunjay K.
    Anderson, Patrick D.
    Meijer, Han E. H.
    MACROMOLECULAR RAPID COMMUNICATIONS, 2009, 30 (4-5) : 362 - 376
  • [45] Numerical Investigation of the Performance of Kenics Static Mixers for the Agitation of Shear Thinning Fluids
    Mahammedi, A.
    Ameur, H.
    Ariss, A.
    JOURNAL OF APPLIED FLUID MECHANICS, 2017, 10 (03) : 989 - 999
  • [46] An improvement of the Sulzer SMX™ static mixer significantly reducing the pressure drop
    Hirschberg, S.
    Koubek, R.
    Moser, F.
    Schoeck, J.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2009, 87 (4A): : 524 - 532
  • [47] Enhancement of photocatalytic degradation of ibuprofen contained in water using a static mixer
    Nunez-Flores, A.
    Sandoval, A.
    Mancilla, E.
    Hidalgo-Millan, A.
    Ascanio, G.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 156 : 54 - 63
  • [48] Design and characterization of a 3D-printed staggered herringbone mixer
    Shenoy, Vedika J.
    Edwards, Chelsea E. R.
    Helgeson, Matthew E.
    Valentine, Megan T.
    BIOTECHNIQUES, 2021, 70 (05)
  • [49] A study on a gas agitated extractor with static mixer
    Ren, XG
    Song, YJ
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 1998, 6 (04) : 361 - 365
  • [50] Laminar heat transfer in the "MLLM" static mixer
    Creyssels, Mathieu
    Prigent, Simon
    Zhou, Yixian
    Xin Jianjin
    Nicot, Christian
    Carriere, Philippe
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 774 - 783