Comparison of several combined/integrated biological-AOPs setups for the treatment of municipal landfill leachate: Minimization of operating costs and effluent toxicity

被引:112
作者
Cassano, D. [2 ,3 ]
Zapata, A. [1 ]
Brunetti, G. [3 ]
Del Moro, G. [2 ]
Di Iaconi, C. [2 ]
Oller, I. [1 ]
Malato, S. [1 ]
Mascolo, G. [2 ]
机构
[1] CIEMAT, Tabernas 04200, Almeria, Spain
[2] CNR, Ist Ric Sulle Acque, I-70132 Bari, Italy
[3] Univ Bari, Dipartimento Biol & Chim Agroforestale & Ambienta, I-70126 Bari, Italy
关键词
Landfill leachate treatment; SBBGR system; Solar photo-Fenton; Ozonation; Operating costs; Toxicity reduction; ADVANCED OXIDATION PROCESSES; RECALCITRANT COMPOUNDS; ORGANIC-COMPOUNDS; LEPIDIUM-SATIVUM; WATER; BIODEGRADABILITY; DEGRADATION; FENTON; TRENDS;
D O I
10.1016/j.cej.2011.05.098
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The treatment of medium-age landfill leachate was investigated by employing several set-ups including a sequencing batch biofilter granular reactor (SBBGR) step, with or without ozone enhancement, followed or not by a polishing stage with solar photo-Fenton (SphF). Objectives of the investigation were to compare different treatment strategies in order to achieve the lowest operating cost and to reduce the toxicity of the final effluent, evaluated by three different tests (respirometry. Vibrio fischeri and Lepidium sativum phytotoxicity). These objectives were addressed for two different target COD values, namely 160 and 500 mg/L. to be met in the final effluent for disposing of to water bodies and to sewers, respectively, requested by Italian environmental regulation. The different treatment strategies have demonstrated to be technically suitable for achieving the requested COD (160 or 500 mg/L) and reduction of the initial toxicity goals. For the COD target of 500 mg/L, the investigated treatment set-ups proposed in this paper showed to have comparable operating cost (3.2 (sic)/m(inf)(3)). Instead, when the target COD is 160 mg/L, the combination SBBGR + SphF is economically more convenient (4.1 (sic)/m(inf)(3)) being the operating cost of the other two investigated treatment set-ups (SBBGR/O-3 and SBBGR/O-3 + SphF) 5.7 and 4.8 (sic)/m(inf)(3). respectively. As far as toxicity reduction is concerned, for both the COD target of 500 and 160 mg/L, the SBBGR/O-3 set-up gave better results than other investigated treatment options. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:250 / 257
页数:8
相关论文
共 37 条
[1]  
Abbas Abdulhussain A., 2009, American Journal of Applied Sciences, V6, P672, DOI 10.3844/ajas.2009.672.684
[2]  
Alkassasbeh Jaffar Y. M., 2009, American Journal of Environmental Sciences, V5, P209, DOI 10.3844/ajessp.2009.209.217
[3]  
[Anonymous], 2006, Gazzetta Ufficiale
[4]  
[Anonymous], 2002, HDB SOLID WASTE MANA
[5]  
[Anonymous], 1999, Standard Methods for Examination of Water and Waste Water
[6]   A comparative study of different tests for biodegradability enhancement determination during AOP treatment of recalcitrant toxic aqueous solutions [J].
Ballesteros Martin, M. M. ;
Casas Lopez, J. L. ;
Oller, I. ;
Malato, S. ;
Sanchez Perez, J. A. .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2010, 73 (06) :1189-1195
[7]  
Beltrami M., 1999, Aquatic Ecosystem Health Management, V2, P391, DOI DOI 10.1016/S1463-4988(99)00036-6
[8]   Assessment of leachates from sanitary landfills: Impact of age, rainfall, and treatment [J].
Chen, PH .
ENVIRONMENT INTERNATIONAL, 1996, 22 (02) :225-237
[9]   Biogeochemistry of landfill leachate plumes [J].
Christensen, TH ;
Kjeldsen, P ;
Bjerg, PL ;
Jensen, DL ;
Christensen, JB ;
Baun, A ;
Albrechtsen, HJ ;
Heron, C .
APPLIED GEOCHEMISTRY, 2001, 16 (7-8) :659-718
[10]   Advanced oxidation processes for water treatment: advances and trends for R&D [J].
Comninellis, Christos ;
Kapalka, Agnieszka ;
Malato, Sixto ;
Parsons, Simon A. ;
Poulios, Loannis ;
Mantzavinos, Dionissios .
JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2008, 83 (06) :769-776