mmHRV: Contactless Heart Rate Variability Monitoring Using Millimeter-Wave Radio

被引:95
作者
Wang, Fengyu [1 ,2 ]
Zeng, Xiaolu [1 ]
Wu, Chenshu [1 ,2 ]
Wang, Beibei [1 ,2 ]
Liu, K. J. Ray [1 ,2 ]
机构
[1] Univ Maryland, Dept Elect & Comp Engn, College Pk, MD 20742 USA
[2] Origin Wireless Inc, Greenbelt, MD 20770 USA
关键词
Heart rate variability; Heart beat; Estimation; Monitoring; RF signals; Interference; Chirp; Heart rate variability (HRV); heartbeat estimation; millimeter-wave (mmWave) radio; wireless sensing; CHEST-WALL; DOPPLER; TRACKING; MOTION; CANCELLATION; RESPIRATION; STRESS;
D O I
10.1109/JIOT.2021.3075167
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heart rate variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. To alleviate the user burden and explore the usability for long-term health monitoring, noncontact methods for HRV monitoring have drawn tremendous attention. In this article, we present mmHRV, the first contact-free multiuser HRV monitoring system using commercial millimeter-wave (mmWave) radio. The design of mmHRV consists of two key components. First, we develop a calibration-free target detector to identify each user's location. Second, a heartbeat signal extractor is devised, which can optimize the decomposition of the phase of the channel information modulated by the chest movement and, thus, estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the interbeat intervals (IBIs) can be further derived for evaluating the HRV metrics of each target. We evaluate the system performance and the impact of different settings, including the distance between human and the device, user orientation, incidental angle, and blockage. Experimental results show that mmHRV can measure the HRV accurately with a median IBI estimation error of 28 ms (with respect to 96.16% accuracy). In addition, the root-mean-square error (RMSE) measured in the nonline-of-sight (NLOS) scenarios is 31.71 ms based on the experiments with 11 participants. The performance of the multiuser scenario is slightly degraded compared with the single-user case; however, the median error of the 3-user case is within 52 ms for all three tested locations.
引用
收藏
页码:16623 / 16636
页数:14
相关论文
共 50 条
[1]   Heart rate variability: a review [J].
Acharya, U. Rajendra ;
Joseph, K. Paul ;
Kannathal, N. ;
Lim, Choo Min ;
Suri, Jasjit S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (12) :1031-1051
[2]   Smart Homes that Monitor Breathing and Heart Rate [J].
Adib, Fadel ;
Mao, Hongzi ;
Kabelac, Zachary ;
Katabi, Dina ;
Miller, Robert C. .
CHI 2015: PROCEEDINGS OF THE 33RD ANNUAL CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS, 2015, :837-846
[3]  
Ahmad A, 2018, IEEE RAD CONF, P1450, DOI 10.1109/RADAR.2018.8378778
[4]  
BITALINO Inc., BIT REV PLUGG KIT BT
[5]   Anxiety disorders are associated with reduced heart rate variability: a meta-analysis [J].
Chalmers, John A. ;
Quintana, Daniel S. ;
Abbott, Maree J. -Anne ;
Kemp, Andrew H. .
FRONTIERS IN PSYCHIATRY, 2014, 5
[6]   TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection [J].
Chen, Chen ;
Han, Yi ;
Chen, Yan ;
Hung-Quoc Lai ;
Zhang, Feng ;
Wang, Beibei ;
Liu, K. J. Ray .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2018, 65 (03) :489-501
[7]   Radios as Sensors [J].
Cianca, Ernestina ;
De Sanctis, Mauro ;
Di Domenico, Simone .
IEEE INTERNET OF THINGS JOURNAL, 2017, 4 (02) :363-373
[8]   Chest wall motion during tidal breathing [J].
DeGroote, A ;
Wantier, M ;
Cheron, G ;
Estenne, M ;
Paiva, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1997, 83 (05) :1531-1537
[9]   Variational Mode Decomposition [J].
Dragomiretskiy, Konstantin ;
Zosso, Dominique .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2014, 62 (03) :531-544
[10]  
Gu C., 2013, P 2013 IEEE MTT S IN, P1, DOI DOI 10.1109/MWSYM.2013.6697618