Coherency-based fast voltage contingency ranking employing counterpropagation neural network

被引:2
作者
Pandit, Manjaree [1 ]
Srivastava, Laxmi
Singh, Vijay
Sharma, Jaydev
机构
[1] MITS, Dept Elect Engn, Gwalior, India
[2] Indian Inst Technol, Roorkee, Uttar Pradesh, India
关键词
voltage security assessment; contingency ranking; coherency-based feature selection; weight initialization; Kohonen layer; Grossberg layer; counterpropagation network;
D O I
10.1016/j.engappai.2007.02.010
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Power system security is one of the major concerns in competitive electricity markets driven by trade demands and regulations. If the system is found to be insecure, timely corrective measures need to be taken to prevent system collapse. This paper presents an approach based on a counterpropagation neural network (CPNN) to identify and rank the contingencies expected to reduce or eliminate the steady-state loadability margin of the system, making it prone to voltage collapse. It has been shown that unlike other artificial neural networks (ANN) paradigms, which start with random weights, CPNN is very sensitive to initial weights. To reduce the dimension and training time, a novel feature selection method, based on the coherency existing between load buses with respect to voltage dynamics, is employed to select significant input features for the CPNN. Once trained, the CPNN is found to rank voltage contingencies accurately for previously unknown system conditions very fast. Due to its fast training, the proposed CPNN will be particularly useful for power system planning studies, as a number of combinations can be tried within a small time frame. The effectiveness of the proposed approach has been demonstrated on IEEE 30-bus test system and a 75-bus practical Indian system. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1133 / 1143
页数:11
相关论文
共 20 条
  • [1] ESTIMATING THE LOADING LIMIT MARGIN TAKING INTO ACCOUNT VOLTAGE COLLAPSE AREAS
    BARQUIN, J
    GOMEZ, T
    PAGOLA, FL
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (04) : 1952 - 1962
  • [2] VOLTAGE STABILITY ASSESSMENT THROUGH MEASUREMENT OF A REDUCED STATE-VECTOR
    BEGOVIC, MM
    PHADKE, AG
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1990, 5 (01) : 198 - 203
  • [3] First and second order methods for voltage collapse assessment and security enhancement
    Berizzi, A
    Finazzi, P
    Dosi, D
    Marannino, P
    Corsi, S
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1998, 13 (02) : 543 - 549
  • [4] POINT OF COLLAPSE AND CONTINUATION METHODS FOR LARGE AC DC SYSTEMS
    CANIZARES, CA
    ALVARADO, FL
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (01) : 1 - 8
  • [5] Radial basis function networks for fast contingency ranking
    Devaraj, D
    Yegnanarayana, B
    Ramar, K
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2002, 24 (05) : 387 - 393
  • [6] AUTOMATIC CONTINGENCY SELECTION
    EJEBE, GC
    WOLLENBERG, BF
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (01): : 97 - 109
  • [7] INVESTIGATION OF LOAD-FLOW PROBLEM
    FRERIS, LL
    SASSON, AM
    [J]. PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1968, 115 (10): : 1459 - &
  • [8] Contingency ranking for voltage collapse via sensitivities from a single nose curve
    Greene, S
    Dobson, I
    Alvarado, FL
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 1999, 14 (01) : 232 - 238
  • [9] Fast voltage contingency screening using radial basis function neural network
    Jain, T
    Srivastava, L
    Singh, SN
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (04) : 1359 - 1366
  • [10] Liu H, 1998, CANCER BIOTHER RADIO, V13, P51