Combination of cool plasma and collision-reaction interface for correction of polyatomic interferences on copper signals in inductively coupled plasma quadrupole mass spectrometry

被引:25
作者
Fialho, Lucimar L. [1 ]
Pereira, Catarinie D. [1 ]
Nobrega, Joaquim A. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Quim, Grp Anal Instrumental Aplicada, BR-13560970 Sao Carlos, SP, Brazil
关键词
ICP-MS; Copper; Cool plasma; Matrix effects; Polyatomic interferences; ICP-MS; CELL; CHROMIUM;
D O I
10.1016/j.sab.2011.04.001
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Inductively coupled plasma mass spectrometry (ICP-MS) is an important instrumental technique for elemental analysis. However, some elements suffer from spectral interferences caused by ions derived from argon plasma gas and matrix components. The determination of copper isotopes is affected by (40)Ar(23)Na(+) and (40)Ar(25)Mg(+). The performance of an ICP-MS with a collision reaction interface (CRI) and cool plasma conditions for correction of spectral interferences was evaluated here. The efficiency of the CRI was studied introducing H(2) or He through sampler and skimmer cones. Gas introduction through the sampler cone was ineffective. Complete elimination of spectral interferences was reached when introducing 60 or 80 mL min(-1) of H(2) in the skimmer cone, but sensitivity losses were as large as 99%. Further, the effect of interferences was checked when the argon plasma was operated under cool plasma conditions. The effects of the applied radiofrequency (0.6, 0.8, 0.9, and 1.0 kW), sampling depth (5.5, 8.5 and 11.5 mm), and dwell time (25 and 50 ms) were studied considering interference reduction and sensitivities. Best conditions were reached at 0.8 kW. Subsequently, both CRI and cool plasma conditions were combined to evaluate their performance on reduction of polyatomic Na and Mg argide interferences. Spectral interferences were eliminated using a CRI with 20 mL min(-1) H(2) introduced through the skimmer cone, cool plasma conditions at 0.8 kW and sampling depth of 8.5 mm. This work demonstrated the feasibility of combining CRI and cool plasma for circumventing some spectral interferences on Cu determination by ICP-QMS. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:389 / 393
页数:5
相关论文
共 16 条
[1]   Copper determination using ICP-MS with hexapole collision cell [J].
Chrastny, Vladislav ;
Komarek, Michael .
CHEMICAL PAPERS, 2009, 63 (05) :512-519
[2]   Method validation for determination of arsenic, cadmium, chromium and lead in milk by means of dynamic reaction cell inductively coupled plasma mass spectrometry [J].
D'Ilio, S. ;
Petrucci, F. ;
D'Amato, M. ;
Di Gregorio, M. ;
Senofonte, O. ;
Violante, N. .
ANALYTICA CHIMICA ACTA, 2008, 624 (01) :59-67
[3]   Determination of chromium, iron and selenium in foodstuffs of animal origin by collision cell technology, inductively coupled plasma mass spectrometry (ICP-MS), after closed vessel microwave digestion [J].
Dufailly, V ;
Noël, L ;
Guérin, T .
ANALYTICA CHIMICA ACTA, 2006, 565 (02) :214-221
[4]   Direct measurement of 44Ca/40 Ca ratios by MC-ICP-MS using the cool plasma technique [J].
Fietzke, J ;
Eisenhauer, A ;
Gussone, N ;
Bock, B ;
Liebetrau, V ;
Nägler, TF ;
Spero, HJ ;
Bijma, J ;
Dullo, C .
CHEMICAL GEOLOGY, 2004, 206 (1-2) :11-20
[5]  
JIANG SJ, 1988, ANAL CHEM, V60, P1218
[6]  
Kalinitchenko I, 2008, SPECTROSCOPY, P38
[7]  
LEENTVAAR L, 1982, WATER RES, V16, P655
[8]   Trace analysis of metals in plant samples with inductively coupled plasma - mass spectrometry [J].
Leiterer, M ;
Einax, JW ;
Loser, C ;
Vetter, A .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 359 (4-5) :423-426
[9]   Determination of Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb in seawater using high resolution magnetic sector inductively coupled mass spectrometry (HR-ICP-MS) [J].
Milne, Angela ;
Landing, William ;
Bizimis, Michael ;
Morton, Peter .
ANALYTICA CHIMICA ACTA, 2010, 665 (02) :200-207
[10]   Measurement of calcium stable isotope tracers using cool plasma ICP-MS [J].
Patterson, KY ;
Veillon, C ;
Hill, AD ;
Moser-Veillon, PB ;
O'Haver, TC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (11) :1673-1677