Advanced in situ metrology for x-ray beam shaping with super precision

被引:43
|
作者
Wang, Hongchang [1 ]
Sutter, John [1 ]
Sawhney, Kawal [1 ]
机构
[1] Diamond Light Source, Didcot OX11 0DE, Oxon, England
来源
OPTICS EXPRESS | 2015年 / 23卷 / 02期
关键词
MIRRORS; OPTICS; INTERFEROMETER;
D O I
10.1364/OE.23.001605
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a novel method for in situ metrology of an X-ray bimorph mirror by using the speckle scanning technique. Both the focusing beam and the "tophat" defocussed beam have been generated by optimizing the bimorph mirror in a single iteration. Importantly, we have demonstrated that the angular sensitivity for measuring the slope error of an optical surface can reach accuracy in the range of two nanoradians. When compared with conventional ex-situ metrology techniques, the method enables a substantial increase of around two orders of magnitude in the angular sensitivity and opens the way to a previously inaccessible region of slope error measurement. Such a super precision metrology technique will be beneficial for both the manufacture of polished mirrors and the optimization of beam shaping. (C) 2015 Optical Society of America
引用
收藏
页码:1605 / 1614
页数:10
相关论文
共 50 条
  • [41] Two-Dimensional X-Ray Beam Phase Sensing
    Berujon, Sebastien
    Ziegler, Eric
    Cerbino, Roberto
    Peverini, Luca
    PHYSICAL REVIEW LETTERS, 2012, 108 (15)
  • [42] 1D X-ray Beam Compressing Monochromators
    Korytar, D.
    Ferrari, C.
    Mikulik, P.
    Vagovic, P.
    Dobrocka, E.
    Ac, V.
    Konopka, P.
    Erko, A.
    Abrosimov, N.
    Zaprazny, Z.
    X-RAY OPTICS AND MICROANALYSIS, PROCEEDINGS, 2010, 1221 : 59 - +
  • [43] Simulated sample heating from a nanofocused X-ray beam
    Wallander, Harald
    Wallentin, Jesper
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 925 - 933
  • [44] Partially coherent x-ray beam simulations: mirrors and more
    Osterhoff, Markus
    Salditt, Tim
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS II, 2011, 8141
  • [45] Speckle-based at-wavelength metrology of X-ray optics at Diamond Light Source
    Wang, Hongchang
    Zhou, Tunhe
    Kashyap, Yogesh
    Sawhney, Kawal
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS IV, 2017, 10388
  • [46] Ground-based X-ray calibration of the Astro-E2 X-ray telescope - I. With pencil beam
    Itoh, A
    Haba, Y
    Hayakawa, A
    Iizuka, R
    Inoue, C
    Inoue, H
    Ishida, M
    Itoh, K
    Kunieda, H
    Maeda, Y
    Misaki, K
    Mori, H
    Naitou, M
    Okada, S
    Shibata, R
    Shimizu, T
    Yokoyama, Y
    UV AND GAMMA-RAY SPACE TELESCOPE SYSTEMS, PTS 1 AND 2, 2004, 5488 : 93 - 102
  • [47] Two-beam X-ray interferometer using prism optics
    Suzuki, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2002, 41 (9A-B): : L1019 - L1021
  • [48] X-ray optics and beam characterization using random modulation: theory
    Berujon, Sebastien
    Cojocaru, Ruxandra
    Piault, Pierre
    Celestre, Rafael
    Roth, Thomas
    Barrett, Raymond
    Ziegler, Eric
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 284 - 292
  • [49] Beam hardening in x-ray differential phase contrast computed tomography
    Bevins, Nicholas
    Zambelli, Joseph
    Li, Ke
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [50] First demonstration of X-ray mirrors using focused ion beam
    Numazawa, Masaki
    Ezoe, Yuichiro
    Ishikawa, Kumi
    Ogawa, Tomohiro
    Sato, Mayu
    Nakamura, Kasumi
    Takeuchi, Kazuma
    Terada, Masaru
    Ohashi, Takaya
    Mitsuda, Kazuhisa
    Kelley, Ron
    Murata, Kaoru
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2016, 55 (06)