Determination of Formaldehyde in Aqueous Samples with a Miniaturized Extraction Capillary Coupled to High-Performance Liquid Chromatography

被引:9
作者
Ueta, Ikuo [1 ]
Mochizuki, Suguru [1 ]
Kawakubo, Susumu [1 ]
Kuwabara, Tetsuo [1 ]
Saito, Yoshihiro [2 ]
机构
[1] Univ Yamanashi, Dept Appl Chem, Kofu, Yamanashi 4008511, Japan
[2] Toyohashi Univ Technol, Dept Environm & Life Sci, Toyohashi, Aichi 4418580, Japan
关键词
Formaldehyde; derivatization; sample preparation; purge and trap; HPLC; VOLATILE ORGANIC-COMPOUNDS; FIBER-PACKED NEEDLE; DEVICE; WATER;
D O I
10.2116/analsci.31.99
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel analytical method for determining formaldehyde (FA) in aqueous samples was developed with a miniaturized extraction capillary in high-performance liquid chromatography (HPLC). The extraction capillary was prepared by packing silica gel particles in a stainless steel capillary of 0.8 mm i.d. and 1.6 mm o.d. A derivatization reagent of 2,4-dinitrophenylhydrazine (DNPH) was impregnated on the silica gel particles by pumping a solution of DNPH to the capillary. Two extraction methods; dynamic extraction and purge-and-trap (PT) methods, were investigated for derivatizing and extracting FA from water samples onto the silica gel in the extraction capillary. The extraction capillary was directly connected to a six-port valve, and then desorption of the derivative from the capillary and injection to conventional HPLC system were simultaneously achieved with a flow of acetonitrile through the capillary. In the dynamic extraction, FA was determined with a simple sample preparation procedure, and the limit of detection (LOD) was 18 mu g L-1 at a sample volume of 20 mL, while several limitations were found in the method, such as bleeding of the derivatization reagent and the corresponding derivatized FA from the capillary during the sample load/extraction process. The sensitivity was significantly improved by introducing a PT technique, where the LOD was 6.9 mu g L-1 at a sample volume of 20 mL with a sampling time of approximately 20 min. With the PT method, successful recoveries of FA were confirmed for spiked tap water, river water and fruit juice samples.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 17 条
[1]   LOW-LEVEL DETERMINATION OF FORMALDEHYDE IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
COTSARIS, E ;
NICHOLSON, BC .
ANALYST, 1993, 118 (03) :265-268
[2]  
IARC Working Group on the Evaluation of Carcinogenic Risks to Humans, 2006, IARC Monogr Eval Carcinog Risks Hum, V88, P1
[3]   HPLC DETERMINATION OF TRACE LEVELS OF ALIPHATIC-ALDEHYDES C-1 - C-4 IN RIVER AND TAP WATER USING ONLINE PRECONCENTRATION [J].
LEHOTAY, J ;
HROMULAKOVA, K .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (03) :579-588
[4]   Determination of formaldehyde in shiitake mushroom by ionic liquid-based liquid-phase microextraction coupled with liquid chromatography [J].
Liu, JF ;
Peng, JF ;
Chi, YG ;
Jiang, GB .
TALANTA, 2005, 65 (03) :705-709
[5]   Fiber-packed needle for dynamic extraction of aromatic compounds [J].
Ogawa, Mitsuhiro ;
Saito, Yoshihiro ;
Ueta, Ikuo ;
Jinno, Kiyokatsu .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (03) :619-625
[6]   Miniaturized sample preparation needle: A versatile design for the rapid analysis of smoking-related compounds in hair and air samples [J].
Saito, Yoshihiro ;
Ueta, Ikuo ;
Ogawa, Mitsuhiro ;
Hayashida, Makiko ;
Jinno, Kiyokatsu .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (01) :1-7
[7]   Simultaneous derivatization/preconcentration of volatile aldehydes with a miniaturized fiber-packed sample preparation device designed for gas chromatographic analysis [J].
Saito, Yoshihiro ;
Ueta, Ikuo ;
Ogawa, Mitsuhiro ;
Jinno, Kiyokatsu .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 386 (03) :725-732
[8]   Fiber-packed needle-type sample preparation device designed for gas chromatographic analysis [J].
Saito, Yoshihiro ;
Ueta, Ikuo ;
Ogawa, Mitsuhiro ;
Abe, Akira ;
Yogo, Kentaro ;
Shirai, Shingoro ;
Jinno, Kiyokatsu .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (03) :861-869
[9]  
U.S. EPA, 1998, DET CARB COMP DRINK
[10]   A novel miniaturized extraction capillary for determining gaseous formaldehyde by high-performance liquid chromatography [J].
Ueta, Ikuo ;
Mochizuki, Suguru ;
Kawakubo, Susumu ;
Kuwabara, Tetsuo ;
Jinno, Kiyokatsu ;
Saito, Yoshihiro .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2015, 407 (03) :899-905