Gadoxetic Acid (Gd-EOB-DTPA)-Enhanced MRI versus Gadobenate Dimeglumine (Gd-BOPTA)-Enhanced MRI for Preoperatively Detecting Hepatocellular Carcinoma: an Initial Experience

被引:38
作者
Park, Yulri [1 ,2 ,3 ]
Kim, Seong Hyun [1 ,2 ]
Kim, Seung Hoon [1 ,2 ]
Jeon, Yong Hwan [4 ]
Lee, Jongmee [5 ]
Kim, Min Ju [5 ]
Choi, Dongil [1 ,2 ]
Lee, Won Jae [1 ,2 ]
Kim, Heejung [1 ,2 ]
Koo, Ji Hyun [1 ,2 ]
Lim, Hyo Keun [1 ,2 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Radiol, Seoul 135710, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Ctr Imaging Sci, Seoul 135710, South Korea
[3] Gachon Univ Gil Hosp, Dept Radiol, Inchon 405760, South Korea
[4] Kangwon Natl Univ Hosp, Dept Radiol, Kangwon Do 200947, South Korea
[5] Korea Univ, Coll Med, Guro Hosp, Dept Radiol, Seoul 152703, South Korea
关键词
Hepatocellular carcinoma (HCC); Gadoxetic acid-enhanced MRI; Gadobenate dimeglumine-enhanced MRI; OPERATING CHARACTERISTIC CURVES; HEPATOBILIARY CONTRAST AGENTS; ENHANCED DYNAMIC MRI; GD-EOB-DTPA; LIVER; CT; PHARMACOKINETICS; SENSITIVITY; MANAGEMENT; DIAMETER;
D O I
10.3348/kjr.2010.11.4.433
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: This study was designed to compare the diagnostic performance of gadoxetic acid-enhanced magnetic resonance imaging (MRI) with gadobenate dimeglumine-enhanced MRI for preoperatively detecting hepatocellular carcinoma (HCC). Materials and Methods: Eighteen consecutive patients (17 men and one woman, age range: 31-73 years) with 22 HCCs underwent examinations with gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI on a 3.0-Tesla unit. The diagnosis of HOC was established after surgical resection and pathological conformation. Three observers independently reviewed each MR image in a random order on a tumor-by-tumor basis. The diagnostic accuracy of these techniques for the detection of HOC was assessed by performing an alternative free-response receiver operating characteristic (ROC) analysis. The sensitivity and positive predictive values were evaluated. Results: The average value of the area under the ROC curve (Az) for gadoxetic acid enhanced MRI (0.887) was not significantly different from the Az (0.899) for gadobenate dimeglumine-enhanced MRI (p > 0.05). The overall sensitivities of gadoxetic acid enhanced MRI and gadobenate dimeglumine-enhanced MRI were 80% and 83%, respectively, with no significant difference (p > 0.05). The differences of the positive predictive values for the two contrast agents for each observer were not statistically significant (p > 0.05). Conclusion: The diagnostic performance of gadoxetic acid-enhanced MRI and gadobenate dimeglumine-enhanced MRI for preoperatively detecting HOC is quite similar.
引用
收藏
页码:433 / 440
页数:8
相关论文
共 33 条
[1]   Hepatocellular carcinoma: Evaluation with biphasic, contrast-enhanced, helical CT [J].
Baron, RL ;
Oliver, JH ;
Dodd, GD ;
Nalesnik, M ;
Holbert, BL ;
Carr, B .
RADIOLOGY, 1996, 199 (02) :505-511
[3]   Characterization of small nodules in cirrhosis by assessment of vascularity: The problem of hypovascular hepatocellular carcinoma [J].
Bolondi, L ;
Gaiani, S ;
Celli, N ;
Goffieri, R ;
Grigioni, WF ;
Leoni, S ;
Venturi, AM ;
Piscaglia, F .
HEPATOLOGY, 2005, 42 (01) :27-34
[4]   Management of hepatoceullular carcinoma [J].
Bruix, J ;
Sherman, M .
HEPATOLOGY, 2005, 42 (05) :1208-1236
[5]   Clinical management of hepatocellular carcinoma.: Conclusions of the Barcelona-2000 EASL Conference [J].
Bruix, J ;
Sherman, M ;
Llovet, JM ;
Beaugrand, M ;
Lencioni, R ;
Burroughs, AK ;
Christensen, E ;
Pagliaro, L ;
Colombo, M ;
Rodés, J .
JOURNAL OF HEPATOLOGY, 2001, 35 (03) :421-430
[6]   Superparamagnetic iron oxide-enhanced liver magnetic resonance imaging - Comparison of 1.5 T and 3.0 T imaging for detection of focal malignant liver lesions [J].
Chang, JM ;
Lee, JM ;
Lee, MW ;
Choi, JY ;
Kim, SH ;
Lee, JY ;
Han, JK ;
Choi, BI .
INVESTIGATIVE RADIOLOGY, 2006, 41 (02) :168-174
[7]   SOLUBLE-TYPE HEPATOBILIARY CONTRAST AGENTS FOR MR IMAGING [J].
DEHAEN, C ;
GOZZINI, L .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (01) :179-186
[8]  
Fleiss JL., 1981, Statistical Methods for Rates and Proportions, V2nd ed, P212, DOI [DOI 10.1002/0471445428.CH18, 10.1002/0471445428.ch18]
[9]   PHASE-I CLINICAL-EVALUATION OF GD-EOB-DTPA AS A HEPATOBILIARY MR CONTRAST AGENT - SAFETY, PHARMACOKINETICS, AND MR-IMAGING [J].
HAMM, B ;
STAKS, T ;
MUHLER, A ;
BOLLOW, M ;
TAUPITZ, M ;
FRENZEL, T ;
WOLF, KJ ;
WEINMANN, HJ ;
LANGE, L .
RADIOLOGY, 1995, 195 (03) :785-792
[10]   A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1983, 148 (03) :839-843