Refractive and Visual Outcomes After Intacs vs Ferrara Intrastromal Corneal Ring Segment Implantation for Keratoconus: A Comparative Study

被引:29
|
作者
Kaya, Vedat [2 ]
Utine, Canan Asli [1 ]
Karakus, Sezen Harmanci [2 ]
Kavadarli, Isilay [2 ]
Yilmaz, Omer Faruk [2 ]
机构
[1] Yeditepe Univ, Dept Ophthalmol, TR-34345 Istanbul, Turkey
[2] Beyoglu Eye Res & Training Hosp, Istanbul, Turkey
关键词
TERM-FOLLOW-UP; FEMTOSECOND LASER; MANAGEMENT; MODERATE; PERFORMANCE; EFFICACY; MODELS;
D O I
10.3928/1081597X-20110906-03
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the refractive, topographic, optical, visual acuity, and quality outcomes of two types of intrastromal corneal ring segments (ICRS) in the treatment of keratoconus. METHODS: In this retrospective study, 16 eyes that had been implanted with Intacs ICRS (Addition Technology Inc) (Intacs group) and 17 eyes implanted with Ferrara ICRS (Ferrara Ophthalmics Ltda) (Ferrara group) were evaluated. Pre- and postoperative examinations included uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), manifest refraction, slit-lamp examination, topography, and ocular wavefront analysis. Contrast sensitivity measurements under photopic, scotopic, and scotopic with glare conditions were performed 1 year postoperatively. RESULTS: One year postoperatively, a significant decrease was noted in spherical equivalent refractive error of 3.76 +/- 0.39 diopters (D) and 3.42 +/- 0.88 D and keratometry of 3.43 +/- 0.24 D and 3.28 +/- 0.78 D in the Intacs and Ferrara groups, respectively; and increase in mean UDVA and CDVA in Snellen lines of 0.18 +/- 0.04 and 0.21 +/- 0.05, respectively, in the Intacs group and 0.21 +/- 0.09 and 0.26 +/- 0.08, respectively, in the Ferrara group (P<.01 for all). The postoperative increase in UDVA and CDVA and decrease in keratometry readings were not significantly different between groups (P>.05 for all). Mean higher order aberrations decreased in the Intacs group and increased in the Ferrara group (P>.05 for both). Postoperatively, a signifi cant decrease was noted in scotopic contrast sensitivity when glare was introduced in the Ferrara group, which was positively correlated with pupil diameter (r(15)= 0.50, P=.04). CONCLUSIONS: Both ICRS types provided comparable refractive, topographic, and optical quality outcomes. Eyes with Ferrara ICRS experienced greater decrease in scotopic contrast sensitivity under glare, which was significantly correlated with pupil diameter. [J Refract Surg. 2011; 27(12): 907-912.] doi:10.3928/1081597X-20110906-03
引用
收藏
页码:907 / 912
页数:6
相关论文
共 50 条
  • [21] Femtosecond laser implantation of a 340-degree intrastromal corneal ring segment in keratoconus: Short-term outcomes
    Sadoughi, Mohammad Mehdi
    Einollahi, Bahram
    Veisi, Amir Reza
    Zare, Mohammad
    Sedaghat, Mohammad Reza
    Roshandel, Danial
    Einollahi, Neda
    Rezaei, Javad
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2017, 43 (10) : 1251 - 1256
  • [22] Outcomes of a Single-Segment Intrastromal Corneal Ring in Early Keratoconus and Early Pellucid Marginal Degeneration
    Hashemian, Seyed Javad
    Abdolalizadeh, Parya
    Ghiasian, Leila
    Aghaei, Hossein
    Hadavandkhani, Ali
    Semnani, Fatemeh Nadjafi
    Jafari, Mohammad Ebrahim
    Hashemian, Seyed Mahyar
    Hashemian, Mahsa Sadat
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (10) : 2987 - 2996
  • [23] Microbial Keratitis After Intrastromal Corneal Ring Segment Implantation
    Emilia Mulet, M.
    Perez-Santonja, Juan J.
    Ferrer, Consuelo
    Alio, Jorge L.
    JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (05) : 364 - 369
  • [24] Comparison of intrastromal corneal ring segment implantation only and in combination with collagen crosslinking for keratoconus
    Cakir, Hanefi
    Pekel, Gokhan
    Perente, Irfan
    Genc, Selim
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (05) : 629 - 634
  • [25] Preliminary results of intrastromal corneal ring segment implantation to treat moderate to severe keratoconus
    Hamdi, Islam M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06) : 1125 - 1132
  • [26] Keratitis after implantation of intrastromal corneal ring segments (Intacs) aided by femtosecond laser for keratoconus correction: case report and description of the literature
    Levy, Jaime
    Lifshitz, Tova
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (04) : 780 - 784
  • [27] Intrastromal corneal ring segment implantation in paracentral keratoconus with perpendicular topographic astigmatism and comatic axis
    Fernandez-Vega-Cueto, Luis
    Lisa, Carlos
    Alfonso-Bartolozzi, Belen
    Madrid-Costa, David
    Alfonso, Jose F.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) : 1540 - 1545
  • [28] Implantation of new intracorneal ring segments after segment explantation for unsuccessful outcomes in eyes with keratoconus
    Alio, Jorge L.
    Pinero, David P.
    Sogutlu, Esin
    Kubaloglu, Anil
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (08) : 1303 - 1310
  • [29] Intrastromal corneal ring segment implantation for irregular astigmatism after laser in situ keratomileusis
    Elies, Daniel
    Luis Gueell, Jose
    Gris, Oscar
    Aristizabal Montes, Diego
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (05) : 912 - 914
  • [30] Intrastromal Corneal Ring Segment Implantation (Keraring 355°) in Patients with Central Keratoconus: 6-Month Follow-Up
    Jadidi, Khosrow
    Mosavi, Seyed Aliasghar
    Nejat, Farhad
    Naderi, Mostafa
    Janani, Leila
    Serahati, Sara
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015