Non-invasive evaluation of coronary artery bypass grafts using 16-row multi-slice computed tomography with 188 ms temporal resolution

被引:37
作者
Burgstahler, C
Beek, T
Kuettner, A
Drosch, T
Kopp, AF
Heuschmid, M
Claussen, CD
Schroeder, S
机构
[1] Univ Tubingen, Div Cardiol, Dept Internal Med, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
关键词
multi-slice computed tomography; 16; row; coronary artery disease; coronary artery bypass graft surgery; imaging technique;
D O I
10.1016/j.ijcard.2005.02.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Cardiac multi-slice computed tomography (MSCT) scanners permit visualization of the coronary arteries and coronary artery bypass grafts. The latest MSCT generation with true 16-detector slices (Sensation 16 Speed 4 DO, Siemens, Forchheim, Germany) provides improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality and accuracy of MSCT diagnosis in patients with previous coronary artery bypass graft (CABG) surgery the following study was conducted. Methods and material: Thirteen consecutive patients (pts) (10 male, 3 female, mean age 62 +/- 6.4 [55-73] years, heart rate 68 +/- 11 [52-88] bpm) and a total number of 43 coronary bypass grafts (I I arterial, 32 venous grafts) were examined by MSCT (gantry rotation time 375 ms). In addition to the analysis of coronary bypass grafts, 13 coronary segments (sgts) were evaluated in each patient (n = 169 sgts). MSCT results were compared with coronary angiography. Results: Forty-one of 43 bypass grafts (95%) were analyzable by MSCT. In conventional angiography 16 of 43 (37%) grafts were occluded. Sixteen of them were correctly diagnosed by MSCT (sensitivity 100%). One graft showed a 50% anastomosis stenosis which was also detected. Twenty-five of 27 grafts without severe lesion showed no significant sterrosis in MSCT (specificity 93%, positive predictive value (PPV) 89%, negative predictive value (NPV) 100%). Ninety of 108 (83%) high-grade stenosis (> 70%) of the native coronary vessels were correctly detected (sensitivity 83%, PPV 78%). From the 61 sgts without high grade stenosis 36 were correctly classified (specificity 59%, NPV 67%). If sgts number 8, 9 and 10, which are normally not target for revascularization, are excluded sensitivity rises to 89%, specificity to 71 %, PPV to 87% and NPV to 75%. The correct clinical diagnosis (absence or presence of a high grade sterrosis of at least one bypass graft) was achieved in all patients. Conclusions: True 16-slice MSCT with faster gantry rotation time allows detection of lesions in coronary artery bypass grafts with high sensitivity and specificity. The evaluation of native vessels in pts with known CAD remains a diagnostic challenge. However, the correct clinical diagnosis was achieved in all pts. MSCT is a non-invasive tool to assess coronary artery bypass grafts. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:244 / 249
页数:6
相关论文
共 15 条
[1]   Editorial comment - Detection of coronary stenoses by multidetector computed tomography: It's all about resolution [J].
Achenbach, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :840-841
[2]   Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography - A segment-based comparison with intravascular ultrasound [J].
Achenbach, S ;
Moselewski, F ;
Ropers, D ;
Ferencik, M ;
Hoffmann, U ;
MacNeill, B ;
Pohle, K ;
Baum, U ;
Anders, K ;
Jang, I ;
Daniel, WG ;
Brady, TJ .
CIRCULATION, 2004, 109 (01) :14-17
[3]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[4]   Non-invasive evaluation of coronary artery bypass grafts using multi-slice computed tomography: initial clinical experience [J].
Burgstahler, C ;
Kuettner, A ;
Kopp, AF ;
Herdeg, C ;
Martensen, J ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 90 (2-3) :275-280
[5]   Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation [J].
Ferencik, M ;
Moselewski, F ;
Ropers, D ;
Hoffmann, U ;
Baum, U ;
Anders, K ;
Pomerantsev, EV ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1257-1262
[6]   Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT: Influence of heart rate on image quality and stenosis detection [J].
Giesler, T ;
Baum, U ;
Ropers, D ;
Ulzheimer, S ;
Wenkel, E ;
Mennicke, M ;
Bautz, W ;
Kalender, WA ;
Daniel, WG ;
Achenbach, S .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (04) :911-916
[7]   Cardiac multidetector-row CT:: Retrospectively ECG-gated spiral with optimized temporal and spatial resolution:: First clinical results. [J].
Kopp, AF ;
Ohnesorge, B ;
Flohr, T ;
Georg, C ;
Schröder, S ;
Küttner, A ;
Martensen, J ;
Claussen, CD .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (05) :429-435
[8]   Diagnostic accuracy of multidetector computed tomography coronary angiography in with angiographically proven coronary artery disease patients [J].
Kuettner, A ;
Kopp, AF ;
Schroeder, S ;
Rieger, T ;
Brunn, J ;
Meisner, C ;
Heuschmid, M ;
Trabold, T ;
Burgstahler, C ;
Martensen, J ;
Schoebel, W ;
Selbmann, HK ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) :831-839
[9]   Noninvasive detection of coronary lesions using 16-detector multislice spiral computed tomography technology - Initial clinical results [J].
Kuettner, A ;
Trabold, T ;
Schroeder, S ;
Feyer, A ;
Beck, T ;
Brueckner, A ;
Heuschmid, M ;
Burgstahler, C ;
Kopp, AF ;
Claussen, CD .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (06) :1230-1237
[10]   Non-invasive assessment of coronary artery bypass graft with retrospectively ECG-gated four-row multi-detector spiral computed tomography [J].
Marano, R ;
Storto, ML ;
Maddestra, N ;
Bonomo, L .
EUROPEAN RADIOLOGY, 2004, 14 (08) :1353-1362