Can the Glittre ADL test differentiate the functional capacity of CORD patients from that of healthy subjects?

被引:57
作者
Correa, Krislainy S. [1 ]
Karloh, Manuela [2 ]
Martins, Leticia Q. [3 ]
dos Santos, Karoliny
Mayer, Anamaria F.
机构
[1] Univ Fed Goias, Programa Posgrad Ciencias Saude, Goiania, Go, Brazil
[2] Univ Estado Santa Catarina UDESC, Programa Posgrad Ciencias Movimento Humano, Florianopolis, SC, Brazil
[3] Univ Fed Uberlandia, Hosp Clin, Curso Residencia Saude Crianca, Uberlandia, MG, Brazil
关键词
evaluation; rehabilitation; activities of daily living; pulmonary disease; chronic obstructive; OBSTRUCTIVE PULMONARY-DISEASE; LONDON CHEST ACTIVITY; LIVING SCALE LCADL; PERIPHERAL MUSCLE WEAKNESS; PHYSICAL-ACTIVITY; OXYGEN DESATURATION; COPD PATIENTS; DAILY-LIFE; WALK TEST; EXERCISE;
D O I
10.1590/S1413-35552011005000034
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: The Glittre ADL (TGlittre) test is a specifically designed to assess functional limitation in chronic obstructive pulmonary disease (COPD) patients. However, it is not known if it can differentiate the performance of these patients from healthy subjects. Objectives: To investigate whether the Glittre ADL test is able to differentiate the functional capacity of COPD patients from that of healthy subjects and to compare the cardiorespiratory response between Glittre ADL and the six-minute walk test (6MWT). Methods: The study included 10 patients with COPD (GOLD 2 to 4) and 10 healthy subjects matched by age who performed the following: spirometry pre-and post-bronchodilator, a Glittre ADL test and two 6MWT on two consecutive days. Results: The performance of COPD (FEV1%pred=38.1 +/- 11.8, age=64 +/- 10 years, BMI=23.7 +/- 5.2 kg/m(2)) was worse than the control group on TGlittre (5.26 +/- 2.9 min, 3.3 +/- 0.3 min, p<0.05) and 6MWT (434.97 +/- 105.18 m vs. 593.25 +/- 87.36 m, p<0.05). TGlittre correlated with the physical activity domain of the London Chest Activity of Daily Living (LCADL) scale (r=0.67, p<0.05) and with 6MWT when the total sample was analyzed (r=-0.64, p<0.05). The COPD group had a statistically higher (p<0.05) increase in dyspnea (Borg scale) than the control group for both TGlittre and 6MWT, with a similar heart rate and peripheral oxygen saturation variation in both groups (p>0.05). Conclusions: The performance of COPD patients is worse than that of healthy subjects on the Glittre ADL test, with a greater increase in dyspnea and similar heart rates.
引用
收藏
页码:467 / 473
页数:7
相关论文
共 37 条
[1]   CARDIAC OUTPUT DURING SUBMAXIMAL + MAXIMAL WORK [J].
ASTRAND, PO ;
SALTIN, B ;
STENBERG, J ;
CUDDY, TE .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (02) :268-+
[2]   Peripheral muscle weakness in patients with chronic obstructive pulmonary-disease [J].
Bernard, S ;
LeBlanc, P ;
Whittom, F ;
Carrier, G ;
Jobin, J ;
Belleau, R ;
Maltais, F .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1998, 158 (02) :629-634
[3]   PSYCHOPHYSICAL BASES OF PERCEIVED EXERTION [J].
BORG, GAV .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 1982, 14 (05) :377-381
[4]  
Carpes Marta Fioravante, 2008, J. bras. pneumol., V34, P143, DOI 10.1590/S1806-37132008000300004
[5]   Distance and Oxygen Desaturation During the 6-min Walk Test as Predictors of Long-term Mortality in Patients With COPD [J].
Casanova, Ciro ;
Cote, Claudia ;
Marin, Jose M. ;
Pinto-Plata, Victor ;
de Torres, Juan P. ;
Aguirre-Jaime, Armando ;
Vassaux, Carlos ;
Celli, Bartolome R. .
CHEST, 2008, 134 (04) :746-752
[6]   ATS statement: Guidelines for the six-minute walk test [J].
Crapo, RO ;
Casaburi, R ;
Coates, AL ;
Enright, PL ;
MacIntyre, NR ;
McKay, RT ;
Johnson, D ;
Wanger, JS ;
Zeballos, RJ ;
Bittner, V ;
Mottram, C .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 166 (01) :111-117
[7]  
de Oca MM, 2005, ARCH BRONCONEUMOL, V41, P413
[8]  
Dechman Gail, 2008, Cardiopulm Phys Ther J, V19, P115
[9]   An evaluation of the reliability and sensitivity of the London Chest Activity of Daily Living Scale (LCADL) [J].
Garrod, R ;
Paul, EA ;
Wedzicha, JA .
RESPIRATORY MEDICINE, 2002, 96 (09) :725-730
[10]   Development and validation of a standardized measure of activity of daily living in patients with severe COPD: the London Chest Activity of Daily Living scale (LCADL) [J].
Garrod, R ;
Bestall, JC ;
Paul, EA ;
Wedzicha, JA ;
Jones, PW .
RESPIRATORY MEDICINE, 2000, 94 (06) :589-596