Four-dimensional flow MRI for evaluation of post-stenotic turbulent flow in a phantom: comparison with flowmeter and computational fluid dynamics

被引:20
作者
Kweon, Jihoon [1 ,2 ]
Yang, Dong Hyun [3 ,4 ]
Kim, Guk Bae [3 ,4 ]
Kim, Namkug [3 ,4 ]
Paek, MunYoung [5 ]
Stalder, Aurelien F. [6 ]
Greiser, Andreas [6 ]
Kim, Young-Hak [1 ,2 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Cardiol, Seoul, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Inst Heart, Seoul, South Korea
[3] Univ Ulsan, Coll Med, Dept Radiol, Asanbyeongwon Gil 86, Seoul 138736, South Korea
[4] Univ Ulsan, Coll Med, Asan Med Ctr, Res Inst Radiol,Cardiac Imaging Ctr, Asanbyeongwon Gil 86, Seoul 138736, South Korea
[5] Siemens Healthcare, Seoul, South Korea
[6] Siemens Healthcare, Erlangen, Germany
基金
新加坡国家研究基金会;
关键词
4D flow MRI; Pathological constriction; Dimensional measurement accuracy; Computational fluid dynamics; PHASE-CONTRAST MRI; AORTIC-VALVE STENOSIS; BLOOD-FLOW; VELOCITY; PATTERNS; QUANTIFICATION; PULMONARY; VELOCIMETRY; PARAMETERS; ARTERY;
D O I
10.1007/s00330-015-4181-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To validate 4D flow MRI in a flow phantom using a flowmeter and computational fluid dynamics (CFD) as reference. Validation of 4D flow MRI was performed using flow phantoms with 75 % and 90 % stenosis. The effect of spatial resolution on flow rate, peak velocity and flow patterns was investigated in coronal and axial scans. The accuracy of flow rate with 4D flow MRI was evaluated using a flowmeter as reference, and the peak velocity and flow patterns obtained were compared with CFD analysis results. 4D flow MRI accurately measured the flow rate in proximal and distal regions of the stenosis (percent error aecurrency sign3.6 % in axial scanning with 1.6-mm resolution). The peak velocity of 4D flow MRI was underestimated by more than 22.8 %, especially from the second half of the stenosis. With 1-mm isotropic resolution, the maximum thickness of the recirculating flow region was estimated within a 1-mm difference, but the turbulent velocity fluctuations mostly disappeared in the post-stenotic region. 4D flow MRI accurately measures the flow rates in the proximal and distal regions of a stenosis in axial scan but has limitations in its estimation of peak velocity and turbulent characteristics. aEuro cent 4D flow MRI accurately measures the flow rate in axial scan. aEuro cent The peak velocity was underestimated by 4D flow MRI. aEuro cent 4D flow MRI demonstrates the principal pattern of post-stenotic flow.
引用
收藏
页码:3588 / 3597
页数:10
相关论文
共 25 条
[1]   Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mapping [J].
Baechler, Pablo ;
Pinochet, Natalia ;
Sotelo, Julio ;
Crelier, Gerard ;
Irarrazaval, Pablo ;
Tejos, Cristian ;
Uribe, Sergio .
MAGNETIC RESONANCE IMAGING, 2013, 31 (02) :178-188
[2]   Bayesian multipoint velocity encoding for concurrent flow and turbulence mapping [J].
Binter, Christian ;
Knobloch, Verena ;
Manka, Robert ;
Sigfridsson, Andreas ;
Kozerke, Sebastian .
MAGNETIC RESONANCE IN MEDICINE, 2013, 69 (05) :1337-1345
[3]   Practical value of cardiac magnetic resonance imaging for clinical quantification of aortic valve stenosis comparison with echocardiography [J].
Caruthers, SD ;
Lin, SJ ;
Brown, P ;
Watkins, MP ;
Williams, TA ;
Lehr, KA ;
Wickline, SA .
CIRCULATION, 2003, 108 (18) :2236-2243
[4]   Quantification of intravoxel velocity standard deviation and turbulence intensity by generalizing phase-contrast MRI [J].
Dyverfeldt, Petter ;
Sigfridsson, Andreas ;
Kvitting, John-Peder Escobar ;
Ebbers, Tino .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (04) :850-858
[5]  
Dyvorne H, 2014, RADIOLOGY
[6]   Magnetic resonance velocimetry: applications of magnetic resonance imaging in the measurement of fluid motion [J].
Elkins, Christopher J. ;
Alley, Marcus T. .
EXPERIMENTS IN FLUIDS, 2007, 43 (06) :823-858
[7]   Postoperative pulmonary and aortic 3D haemodynamics in patients after repair of transposition of the great arteries [J].
Geiger, Julia ;
Hirtler, Daniel ;
Buerk, Jonas ;
Stiller, Brigitte ;
Arnold, Raoul ;
Jung, Bernd ;
Langer, Mathias ;
Markl, Michael .
EUROPEAN RADIOLOGY, 2014, 24 (01) :200-208
[8]   3D Blood Flow Characteristics in the Carotid Artery Bifurcation Assessed by Flow-Sensitive 4D MRI at 3T [J].
Harloff, A. ;
Albrecht, F. ;
Spreer, J. ;
Stalder, A. F. ;
Bock, J. ;
Frydrychowicz, A. ;
Schoellhorn, J. ;
Hetzel, A. ;
Schumacher, M. ;
Hennig, J. ;
Markl, M. .
MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (01) :65-74
[9]   Bicuspid Aortic Valve: Four-dimensional MR Evaluation of Ascending Aortic Systolic Flow Patterns [J].
Hope, Michael D. ;
Hope, Thomas A. ;
Meadows, Alison K. ;
Ordovas, Karen G. ;
Urbania, Thomas H. ;
Alley, Marcus T. ;
Higgins, Charles B. .
RADIOLOGY, 2010, 255 (01) :53-61
[10]   Comparison of flow patterns in ascending aortic aneurysms and volunteers using four-dimensional magnetic resonance velocity mapping [J].
Hope, Thomas A. ;
Markl, Michael ;
Wigstrom, Lars ;
Alley, Marcus T. ;
Miller, D. Craig ;
Herfkens, Robert J. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (06) :1471-1479