Method validation for the determination of propellant components by Soxhlet extraction and gas chromatography/mass spectrometry

被引:17
作者
Frys, Ondrej [1 ]
Bajerova, Petra [1 ]
Eisner, Ales [1 ]
Mudrunkova, Martina [2 ]
Ventura, Karel [1 ]
机构
[1] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, CZ-53210 Pardubice, Czech Republic
[2] Explosia As Res Inst Ind Chem VUPCH, Pardubice, Czech Republic
关键词
Analysis; Explosives; Extraction; Gas chromatography; MS; SOLID-PHASE EXTRACTION; LIQUID; WATER;
D O I
10.1002/jssc.201100279
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fast, sensitive, and accurate GC/MS method for the quantification of aliphatic nitroesters (ethylene glycol dinitrate, nitroglycerin, and triethylene glycol dinitrate) and aromatic amines (diphenylamine, 2-nitrodiphenylamine, and triphenylamine) in propellants was developed and validated. This method comprises a Soxhlet extraction step with dichloromethane, followed by separation on a capillary column MDN-5. Ionization of the analytes is carried out using electron ionization. The limit of quantification of the method was 1% w/w for aliphatic nitroesters and 0.1% w/w for aromatic amines (diphenylamine and triphenylamine). Values of repeatability and reproducibility for analyzed compounds were smaller than values of the maximum allowed tolerances of the Horwitz-equation RSDmax and 2/3 RSDmax. Values of accuracy for selected compounds were below the acceptable threshold of 15% for all tested levels in the range of calibration curve excepting the lowest concentration of calibration curve for nitroglycerin and aromatic amines. During the validation of method, temperature instability in injection port of gas chromatograph and column was observed for 2-nitrodiphenylamine. Hence, it follows worse results of accuracy and linearity and 2-nitrodiphenylamine was not validated successfully.
引用
收藏
页码:2405 / 2410
页数:6
相关论文
共 10 条
[1]   Validation of liquid chromatographic and gas chromatographic methods - Applications to pharmacokinetics [J].
Bressolle, F ;
BrometPetit, M ;
Audran, M .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (01) :3-10
[2]   Quantitative analysis of androst-4-ene-3,6,17-trione and metabolites in human urine after the administration of a food supplement by liquid chromatography/ion trap-mass spectrometry [J].
Deventer, K ;
Van Eenoo, P ;
Mikulcíková, P ;
Van Thuyne, W ;
Delbeke, FT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2) :21-26
[3]  
Frys O, 2010, CENT EUR J ENERG MAT, V7, P253
[4]   Determination of nitrate esters in water samples comparison of efficiency of solid-phase extraction and solid-phase microextraction [J].
Jezova, Vera ;
Skladal, Jan ;
Eisner, Ales ;
Bajerova, Petra ;
Ventura, Karel .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) :13-19
[5]   Detection of odor signatures of smokeless powders using solid phase microextraction coupled to an ion mobility spectrometer [J].
Joshi, Monica ;
Delgado, Yisenny ;
Guerra, Patricia ;
Lai, Hanh ;
Almirall, Jose R. .
FORENSIC SCIENCE INTERNATIONAL, 2009, 188 (1-3) :112-118
[6]   Mobile phase influence on electrospray ionization for the analysis of smokeless powders by gradient reversed phase high-performance liquid chromatography-ESIMS [J].
Mathis, JA ;
McCord, BR .
FORENSIC SCIENCE INTERNATIONAL, 2005, 154 (2-3) :159-166
[7]   Comparing solid phase extraction and direct injection for the analysis of ultra-trace levels of relevant explosives in lake water and tributaries using liquid chromatography-electrospray tandem mass spectrometry [J].
Ochsenbein, Ueli ;
Zeh, Markus ;
Berset, Jean-Daniel .
CHEMOSPHERE, 2008, 72 (06) :974-980
[8]   Characterization of smokeless powders using nanoelectrospray ionization mass spectrometry (nESI-MS) [J].
Scherperel, Gwynyth ;
Reid, Gavin E. ;
Smith, Ruth Waddell .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (08) :2019-2028
[9]   Triphenylamine -: a 'new' stabilizer for nitrocellulose based propellants -: Part I:: Chemical stability studies [J].
Wilker, Stephan ;
Heeb, Gerhard ;
Vogelsanger, Beat ;
Petrzilek, Jan ;
Skladal, Jan .
PROPELLANTS EXPLOSIVES PYROTECHNICS, 2007, 32 (02) :135-148
[10]   Ionic liquid for improved single-drop microextraction of aromatic amines in water samples [J].
Zhou, Qingxiang ;
Ye, Cunling .
MICROCHIMICA ACTA, 2008, 162 (1-2) :153-159