Engineered Glucose Oxidase Capable of Quasi-Direct Electron Transfer after a Quick-and-Easy Modification with a Mediator

被引:43
作者
Suzuki, Nanami [1 ]
Lee, Jinhee [2 ,3 ]
Loew, Noya [2 ,3 ]
Takahashi-Inose, Yuka [4 ]
Okuda-Shimazaki, Junko [2 ,3 ]
Kojima, Katsuhiro [4 ]
Mori, Kazushige [4 ]
Tsugawa, Wakako [1 ]
Sode, Koji [2 ,3 ]
机构
[1] Tokyo Univ Agr & Technol, Grad Sch Engn, Dept Biotechnol & Life Sci, 2-24-16 Naka Cho, Koganei, Tokyo 1848588, Japan
[2] Univ N Carolina, Joint Dept Biomed Engn, Chapel Hill, NC 27599 USA
[3] North Carolina State Univ, Chapel Hill, NC 27599 USA
[4] Ultizyme Int Ltd, Sumida Ku, 3-9-5 Taihei, Tokyo 1300012, Japan
关键词
glucose oxidase; direct electron transfer; amine-reactive phenazine ethosulfate; glucose sensor; glycemic level monitoring; CHEMICALLY-MODIFIED ENZYMES; METAL-ELECTRODES; RELAYS; COMMUNICATION; DEHYDROGENASE; ATTACHMENT;
D O I
10.3390/ijms21031137
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Glucose oxidase (GOx) has been widely utilized for monitoring glycemic levels due to its availability, high activity, and specificity toward glucose. Among the three generations of electrochemical glucose sensor principles, direct electron transfer (DET)-based third-generation sensors are considered the ideal principle since the measurements can be carried out in the absence of a free redox mediator in the solution without the impact of oxygen and at a low enough potential for amperometric measurement to avoid the effect of electrochemically active interferences. However, natural GOx is not capable of DET. Therefore, a simple and rapid strategy to create DET-capable GOx is desired. In this study, we designed engineered GOx, which was made readily available for single-step modification with a redox mediator (phenazine ethosulfate, PES) on its surface via a lysine residue rationally introduced into the enzyme. Thus, PES-modified engineered GOx showed a quasi-DET response upon the addition of glucose. This strategy and the obtained results will contribute to the further development of quasi-DET GOx-based glucose monitoring dedicated to precise and accurate glycemic control for diabetic patient care.
引用
收藏
页数:10
相关论文
共 31 条
  • [1] INTRAMOLECULAR ELECTRON-TRANSFER RATES IN FERROCENE-DERIVATIZED GLUCOSE-OXIDASE
    BADIA, A
    CARLINI, R
    FERNANDEZ, A
    BATTAGLINI, F
    MIKKELSEN, SR
    ENGLISH, AM
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1993, 115 (16) : 7053 - 7060
  • [2] Fast electron transfer between glucose oxidase and electrodes via phenothiazine mediators with poly(ethylene oxide) spacers attached to the enzyme surface
    Ban, K
    Ueki, T
    Tamada, Y
    Saito, T
    Imabayashi, S
    Watanabe, M
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2001, 3 (11) : 649 - 653
  • [3] There is no evidence to support literature claims of direct electron transfer (DET) for native glucose oxidase (GOx) at carbon nanotubes or graphene
    Bartlett, Philip N.
    Al-Lolage, Firas A.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 819 : 26 - 37
  • [4] ENZYME ELECTRODE STUDIES OF GLUCOSE-OXIDASE MODIFIED WITH A REDOX MEDIATOR
    BARTLETT, PN
    BRADFORD, VQ
    WHITAKER, RG
    [J]. TALANTA, 1991, 38 (01) : 57 - 63
  • [5] COVALENT BINDING OF ELECTRON RELAYS TO GLUCOSE-OXIDASE
    BARTLETT, PN
    WHITAKER, RG
    GREEN, MJ
    FREW, J
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1987, (20) : 1603 - 1604
  • [6] Modification of glucose oxidase by the covalent attachment of a tetrathiafulvalene derivative
    Bartlett, PN
    Booth, S
    Caruana, DJ
    Kilburn, JD
    Santamaria, C
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 734 - 742
  • [7] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [8] Mediated biosensors
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 441 - 456
  • [9] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [10] DIRECT ELECTRICAL COMMUNICATION BETWEEN CHEMICALLY MODIFIED ENZYMES AND METAL-ELECTRODES .2. METHODS FOR BONDING ELECTRON-TRANSFER RELAYS TO GLUCOSE-OXIDASE AND D-AMINO-ACID OXIDASE
    DEGANI, Y
    HELLER, A
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1988, 110 (08) : 2615 - 2620